Lennox package unit no AC/loss of comm with EMS

  Рет қаралды 17,222

Curious HVAC Guy

Curious HVAC Guy

Күн бұрын

Пікірлер: 32
@sergioramirez9025
@sergioramirez9025 2 жыл бұрын
I love how the way you explain everything brother much appreciated 💯🍻
@markandsuriyonphanasonkath8768
@markandsuriyonphanasonkath8768 4 жыл бұрын
EXCELLENT video, many thanks! Regards from Phuket in Thailand :-)
@Brendan_Clancy
@Brendan_Clancy 4 жыл бұрын
On the data plate, the item labelled Evaporator is the indoor blower motor
@kensster8763
@kensster8763 2 жыл бұрын
For the EMS board.. take that fuse out. Then you can jumper out the relays you want to test.. example: stage 1 heating or cooling stage 1.. ETC. on that relay you will see the 2 male spades on the same relay. jumper them together as connect them on the same relay.. voila. I find testing the cooling stage is best for last when I test for all
@actechformallyyomama746
@actechformallyyomama746 5 жыл бұрын
The ambient pressure switch maintains pressure above freezing. Like on a server room unit that runs all year. On R22 the condenser fan should come on around 275psi with a differential of 50psi. So off around 225psi. This keeps the evaporator temp above 32 degrees.
@bigclivedotcom
@bigclivedotcom 4 жыл бұрын
I always hate the unknown variables of turning up after someone else has walked away with the unit turned off. You wonder if something's going to go bang when you turn it on again or if there's a miswiring booby trap. Your sound is really good with a compressor and fan running. Are you using a phone to record? (I use Moto G's for my own videos.)
@curioushvacguy6876
@curioushvacguy6876 4 жыл бұрын
Your exactly right Clive- theres a bit of nervousness when you start playing around in a machine that is just left off, never know whats going to happen
@sterlingarcher46
@sterlingarcher46 5 жыл бұрын
Bloody control board with no screen , just switches and codes ,urgh ! I'm gonna stop complaining about the RTUs I work on , they might be complicated, but at least they have a controller with s screen and buttons ! Kudos to you fellas !
@curioushvacguy6876
@curioushvacguy6876 5 жыл бұрын
Are you working on the prodigy system?
@sterlingarcher46
@sterlingarcher46 5 жыл бұрын
@@curioushvacguy6876 not at all , I usually work on systems with Carel regulators or such , the nice thing is they have a screen and buttons 👍
@jeffrobison2013
@jeffrobison2013 4 жыл бұрын
worst place i ever had to get to was a euipment room above a jail, cell on second floor, hvac on third. to get there enter the basement and climb a 4 story ladder, they had a winch to bring up tools and equipment. this whole system was ground source.
@abelurrutia1192
@abelurrutia1192 4 жыл бұрын
I don’t think there’s any pistons in that scroll compressor.
@BrettWae
@BrettWae 2 жыл бұрын
Wouldn't the reclaim coil be a condenser since its routing hot discharge gas through that coil downstream of the evaporator?? Evaporator dehumidifies and chills the air so the reheat coil uses hot gas to raise the temp back up so you have dehumidified air at the temperature you want? Love the videos man!
@steveblake8766
@steveblake8766 5 жыл бұрын
#42 Thumbs up I was about to lose my lunch on that ride up to the roof....:)
@kennethlobo4420
@kennethlobo4420 3 жыл бұрын
Great video.where can I get a manual on this unit like the one U referred to? Just to have a better idea on these units
@brandonprice3927
@brandonprice3927 5 жыл бұрын
Any idea why that compressor was so dog on loud?
@romefl6723
@romefl6723 3 жыл бұрын
U are looking at low ambient switch , it is basically a cfan cycle switch .
@chriscooley906
@chriscooley906 5 жыл бұрын
So that low ambient switch acts like a head master?
@robertpeters9438
@robertpeters9438 2 жыл бұрын
Doesn't the reheat cool come AFTER THE evaporator, not before?
@johnnyb8629
@johnnyb8629 4 жыл бұрын
lol, I swear I work for same company broah. I take care of Chicago, retail commercial and deal with same shit. I've been doing this over 20 years though so I'm sick of it.
@chriscooley906
@chriscooley906 5 жыл бұрын
Thanks curious nicely said
@thedeadpoet33
@thedeadpoet33 2 жыл бұрын
Where do you find the physical manuals?
@romefl6723
@romefl6723 3 жыл бұрын
On novar u have to jump idm fan and y1 .
@randomrefrigeration4564
@randomrefrigeration4564 3 жыл бұрын
Goes through the evap 1st not the reheat coil
@SombraLocs
@SombraLocs 5 жыл бұрын
So is that second evaporator like a reheat coil?
@SombraLocs
@SombraLocs 5 жыл бұрын
Should have finished watching the whole video before I commented.
@romefl6723
@romefl6723 3 жыл бұрын
Should have checked ur amp draw on cfan .
@syedbasheer8210
@syedbasheer8210 5 жыл бұрын
👨‍🔧🍾
@curioushvacguy6876
@curioushvacguy6876 5 жыл бұрын
Thanks
@randomrefrigeration4564
@randomrefrigeration4564 3 жыл бұрын
Dude it’s in free cooling
@romefl6723
@romefl6723 3 жыл бұрын
Comp sounds like crap.
@romefl6723
@romefl6723 3 жыл бұрын
Novar crap , ems is useless , corporate micro management.
Carrier package unit not cooling: Part 2
20:43
Curious HVAC Guy
Рет қаралды 12 М.
LENNOX PACKAGE UNIT HIGH HEAD PRESSURE
19:12
HVACR VIDEOS
Рет қаралды 50 М.
Мясо вегана? 🧐 @Whatthefshow
01:01
История одного вокалиста
Рет қаралды 7 МЛН
Beat Ronaldo, Win $1,000,000
22:45
MrBeast
Рет қаралды 158 МЛН
Stop Wasting Money on New Batteries! Restore Old AA Batteries Today!
18:17
All 3 Ac units not cooling
24:47
Curious HVAC Guy
Рет қаралды 10 М.
Faulty Ubiquiti POE Network Switch | Can I Fix It?
31:22
Buy it Fix it
Рет қаралды 53 М.
Lennox package unit low on refrigerant
15:52
Curious HVAC Guy
Рет қаралды 10 М.
Carrier package unit No AC
18:01
Curious HVAC Guy
Рет қаралды 36 М.
Lennox RTU Troubleshooting, Is It A Faulty Control Board?
5:52
HVAC Know It All
Рет қаралды 29 М.
EMS Systems
22:28
David Harty
Рет қаралды 14 М.