Trane VOYAGER Test Mode

  Рет қаралды 6,902

D2D NY Real World HVAC Simplified

D2D NY Real World HVAC Simplified

Күн бұрын

Troubleshooting Trane AC using test mode,
Beginners and pros how to use test function on Trane RTU ac units, to turn on every function without using the thermostat or it’s terminal block
#tranehvac #d2dnyac

Пікірлер: 17
@joshuaricks7730
@joshuaricks7730 2 жыл бұрын
If you have wires connected to 1-14 you cannot jump at the conventional terminals. ( R G Y W C ) it set higher priority to the 5vdc circuit
@D2DNYAC
@D2DNYAC 2 жыл бұрын
Ooh 👍 thanks for stopping by
@arminbrambila9118
@arminbrambila9118 2 жыл бұрын
I put a jumper between Test 1 and Test 2 It worked ok, and I did it again and the Electronic Board Turned off, I can't see the leds flashings, I had to disconnect and comect the electrical supply and then the board turned on. What happened here? Thanks
@D2DNYAC
@D2DNYAC 2 жыл бұрын
If you are using the screw terminals they may be corroded so it's a hit or a miss best to go behind! And if not then the unit may have a control short on either economizer, HEATING or cooling circuit, so I would do it test again and pay close attention to what stage or mode of test the led goes out ie fan, economizer, HEATING cooling etc
@Bluecollarrebel
@Bluecollarrebel 4 жыл бұрын
🤙
@joehead1294
@joehead1294 3 жыл бұрын
Do NAVAC hoses have some sort of check valve in the hose, as there is no shut-off or does it not need it as it is not a manifold gauge.
@D2DNYAC
@D2DNYAC 3 жыл бұрын
No check valve here, and this is an actual gauge and manifold! This gauge and manifold was geared towards mini splits being that they only have one service port.
@joehead1294
@joehead1294 3 жыл бұрын
@@D2DNYAC Yeah, I guess I think manifold has more than one gauge, you are correct. Does it not need shut-off down at end of hose, Montreal Protocol?
@JuanSanchez-nn1db
@JuanSanchez-nn1db Жыл бұрын
What model of Navac gauges are those?
@D2DNYAC
@D2DNYAC Жыл бұрын
i will let you know
@jractk
@jractk 3 жыл бұрын
Put the door on over the compressors when reading pressures!
@D2DNYAC
@D2DNYAC 3 жыл бұрын
Sure that’s the correct way to do it
@richardreynoso7260
@richardreynoso7260 4 жыл бұрын
I got circuit 1 compressor do not started help
@D2DNYAC
@D2DNYAC 4 жыл бұрын
Got to give me more information than that! If u need me to help
@phillipsierra2074
@phillipsierra2074 3 жыл бұрын
Find a professional
@globaltecnicianworldsbest3031
@globaltecnicianworldsbest3031 4 жыл бұрын
What's reliatel?
@D2DNYAC
@D2DNYAC 2 жыл бұрын
Tranes control board inside its smaller RTUs that's capable of using standard non trane thermostats
HVAC TROUBLESHOOTING
23:18
D2D NY Real World HVAC Simplified
Рет қаралды 12 М.
Crucial Knowledge To Heat Pump Troubleshooting
14:15
Jersey Mike HVAC
Рет қаралды 29 М.
طردت النملة من المنزل😡 ماذا فعل؟🥲
00:25
Cool Tool SHORTS Arabic
Рет қаралды 33 МЛН
Blue Food VS Red Food Emoji Mukbang
00:33
MOOMOO STUDIO [무무 스튜디오]
Рет қаралды 33 МЛН
When you discover a family secret
00:59
im_siowei
Рет қаралды 33 МЛН
Trane RTU Test Mode
6:54
MarzMan
Рет қаралды 16 М.
Trane voyager thermostat interface board
6:56
Michigan Heating Guy
Рет қаралды 11 М.
TRANE VOYAGER CALL BACK
22:45
HVACR VIDEOS
Рет қаралды 91 М.
Why Heat Pumps are now leaving people COLD
5:31
Silver Cymbal
Рет қаралды 231 М.
HVAC TROUBLESHOOTING
22:33
D2D NY Real World HVAC Simplified
Рет қаралды 17 М.
TRANE VOYAGER NOT COOLING
15:02
HVACR VIDEOS
Рет қаралды 59 М.
HVAC TROUBLESHOOTING |   A/C NOT COOLING
35:49
D2D NY Real World HVAC Simplified
Рет қаралды 8 М.
trane unit with bad RTRM board
14:30
Anthony Reardon hvacr
Рет қаралды 33 М.
AC Pressures, Subcooling and Superheat
29:52
HVAC School
Рет қаралды 259 М.