HVAC TIP AND TRICK
2:52
Күн бұрын
ECM TO PSC MOTOR CONVERSION Pt2
11:30
14 күн бұрын
COMMERCIAL HEATING FURNACE
3:27
ECM TO PSC BLOWER MOTOR CONVERSION
12:17
ADDING REFRIGERANT
7:41
3 ай бұрын
WORKS LIKE MAGIC  😎
0:34
4 ай бұрын
TRANE CHILLER |TECHVIEW | CH530
14:28
YASKAWA V1000 FAULTS
4:58
6 ай бұрын
HVAC TROUBLESHOOTING
2:40
7 ай бұрын
Пікірлер
@WhatIsYourCard
@WhatIsYourCard 2 сағат бұрын
how to pull the slowest vacuum possible without verifying you are pulling good vacuum
@DJV94022
@DJV94022 Күн бұрын
False😂
@jjp5041
@jjp5041 Күн бұрын
The alarm always brings a smile to my 😊
@Jonathan-hx6oy
@Jonathan-hx6oy 3 күн бұрын
I have that field piece sniffer, and an infinticon the infinticon is 1000x better. The field piece self zeros and just gives you a 1-100 "strength" reading. Infinticon actually give you a constant ppm reading. Lets you back sniff any leak. I have found leaks by patterning across store chasing the air flow when there are dozens of coolers. Habitually carry it on when working on other jobs. Just in case i run into a leak.
@D2DNYAC
@D2DNYAC 3 күн бұрын
Really what model inficon?
@Jonathan-hx6oy
@Jonathan-hx6oy 3 күн бұрын
@@D2DNYAC the Stratus. I started with the field piece but got frustrated with its self zeroing function really fast. I'm in commercial/rack refrigeration so getting beep beep beep while standing in middle of rows of coolers with 2 dozen or more evaps is very not helpful. Especially when it "zeros" itself and you lose the trail because chasing the breeze.
@Mudo94
@Mudo94 Күн бұрын
@@Jonathan-hx6oystratus better than the h-10 pro?
@Jonathan-hx6oy
@Jonathan-hx6oy Күн бұрын
@@Mudo94 i can't say i haven't used h-10 as far as i know
@WhatIsYourCard
@WhatIsYourCard 3 сағат бұрын
@@Mudo94 H10 is the best heated diode refrigerant leak detecter on the market, it's main downside is the high cost of part replacement and lack of that flexible neck
@Fatedcauze
@Fatedcauze 4 күн бұрын
Checks to see if the pilot ignited. Fought with one for weeks on our hot melt oven.
@D2DNYAC
@D2DNYAC 3 күн бұрын
If the pilot doesn’t get ignited the main valve won’t open and the pilot indicator light will stay off and the controller goes into alarm
@Fatedcauze
@Fatedcauze 3 күн бұрын
@@D2DNYAC We had an issue where the "butterfly" was staying open and blowing out the pilot when we initiated the main valve. I didn't really fix the issue, I just dial down the temp on start up, that butterfly closes to "idle" and then I can start it. We use Honeywell controllers and were getting code 19 and I think it was 17 both a flame out iirc. The ovens we use are old, 1989 on the plate. Prior to working where I do now, I only had basic home experience. I've been watching a few of you content creators on YT and want to thank you for your channel. It really has helped me with diagnosing issues. Edit: the controller we use is the exact one in the video.
@MohamedElbastwecy
@MohamedElbastwecy 6 күн бұрын
I want to learn HVAC, but there are those who say the learning period is 6 months, and there are those who say 2 years, and there are those who say 4 years, which is true?
@D2DNYAC
@D2DNYAC 6 күн бұрын
To get up and going solo I would say 1 to 2 years however you never stop learning my friend
@jfrancis98
@jfrancis98 6 күн бұрын
Dimple is for setting the concentric locking collar. Thanks for your videos. Very informative.
@D2DNYAC
@D2DNYAC 6 күн бұрын
Dimple?
@jfrancis98
@jfrancis98 6 күн бұрын
@@D2DNYAC the 3rd partially drilled hole on the locking collar.
@aik-charwaha
@aik-charwaha 6 күн бұрын
No volume Irritating sound around Incomplete video Next time don't make such stupid video
@deryckramjattan3467
@deryckramjattan3467 7 күн бұрын
I need a kkt tech
@D2DNYAC
@D2DNYAC 6 күн бұрын
Where are you located?
@michaelgiuliano5700
@michaelgiuliano5700 8 күн бұрын
That because the fans running the wrong way. Simple fix
@D2DNYAC
@D2DNYAC 6 күн бұрын
Nope
@D2DNYAC
@D2DNYAC 6 күн бұрын
The fan is spinning backwards because of air pulling through by the fan that's running and this fan is bad
@rays1418
@rays1418 8 күн бұрын
Will this unit tells you of a transducer issue or the actual pressure readings?
@D2DNYAC
@D2DNYAC 8 күн бұрын
Yes and yes
@joemartinez-673
@joemartinez-673 9 күн бұрын
Wet switch wiring
@D2DNYAC
@D2DNYAC 9 күн бұрын
Thanks for watching
@ecoTOPeco
@ecoTOPeco 10 күн бұрын
What is blue staff?
@D2DNYAC
@D2DNYAC 10 күн бұрын
Leak lock seals the threads
@Dantes-_-Inferno
@Dantes-_-Inferno 10 күн бұрын
Just picked up a set this morning. Thanks for the video
@D2DNYAC
@D2DNYAC 10 күн бұрын
Very nice
@lilounce6404
@lilounce6404 5 күн бұрын
How are you liking them so far? I’m considering getting them or the fieldpeice smans
@mxxmikexx1
@mxxmikexx1 10 күн бұрын
And also, when you add 2 or more wireless sensors, does the thermostat then automatically take the average reading of those various sensors? or are there more options to setup how the thermostat reads the multiple sensors?
@D2DNYAC
@D2DNYAC 8 күн бұрын
you have to go into setup a d set which remote temp sensor to use for control or averaging
@mxxmikexx1
@mxxmikexx1 10 күн бұрын
can you add these wireless sensors to an existing thermostat that is already setup and functioning? or do you have to do a factory reset on the thermostat and start all over setting up the thermostat?
@D2DNYAC
@D2DNYAC 8 күн бұрын
You can move them from thermostat to thermostat just disconnect device then do the link process for each sensor
@Jobychayan4085
@Jobychayan4085 11 күн бұрын
How to get this tool
@D2DNYAC
@D2DNYAC 10 күн бұрын
Buy it online
@Jobychayan4085
@Jobychayan4085 6 күн бұрын
@@D2DNYAC have any link this not getting online
@dennisssolea1508
@dennisssolea1508 11 күн бұрын
Thank you for the breakdown
@D2DNYAC
@D2DNYAC 10 күн бұрын
Thanks for watching
@user-hd8ve2bz3b
@user-hd8ve2bz3b 11 күн бұрын
What is the chiller model?
@D2DNYAC
@D2DNYAC 10 күн бұрын
This isn't a chiller
@joseaguirre2442
@joseaguirre2442 12 күн бұрын
Why is the compresor. Not on the right place you need to calibrate the bolts … and also you didn’t purge the lines before connecting the compressor…
@D2DNYAC
@D2DNYAC 11 күн бұрын
Thanks for sharing
@Jobychayan4085
@Jobychayan4085 12 күн бұрын
Good idea
@D2DNYAC
@D2DNYAC 12 күн бұрын
Ooh yeah
@monisyaseenmughal9714
@monisyaseenmughal9714 12 күн бұрын
Please can you explain how to adress indoor units and how to check adress of indoors.thanks
@D2DNYAC
@D2DNYAC 12 күн бұрын
By the rotary dial switches
@mattwoodbridge7924
@mattwoodbridge7924 12 күн бұрын
That wouldn't be a bad idea in southern California either. 😅
@D2DNYAC
@D2DNYAC 12 күн бұрын
😂
@yoshisatoshi3206
@yoshisatoshi3206 13 күн бұрын
We appreciate you !!!
@D2DNYAC
@D2DNYAC 12 күн бұрын
Okay thanks look out the video
@yoshisatoshi3206
@yoshisatoshi3206 13 күн бұрын
Shaky Warrior 😂
@D2DNYAC
@D2DNYAC 11 күн бұрын
😂
@workingshlub8861
@workingshlub8861 13 күн бұрын
great video...
@D2DNYAC
@D2DNYAC 11 күн бұрын
Thanks for watching
@gorillamad7544
@gorillamad7544 13 күн бұрын
Does this require schooling to learn or can it be done simple enough for a DIY
@D2DNYAC
@D2DNYAC 11 күн бұрын
Schooling
@D2DNYAC
@D2DNYAC 11 күн бұрын
Or diy to a certain extent
@ferozeyacoob3033
@ferozeyacoob3033 14 күн бұрын
Helpful .Thanks. questions. On the PUMY model citymulti can you exchange the controller (for the indoor unit) with one from another unit that is not in use?
@D2DNYAC
@D2DNYAC 13 күн бұрын
Yes
@nickthegriffin
@nickthegriffin 15 күн бұрын
Hi great video could you point me in the direction of the software? 👍
@D2DNYAC
@D2DNYAC 15 күн бұрын
Okay stay tuned I will upload a video on that
@portapottyflipper6957
@portapottyflipper6957 16 күн бұрын
Nice
@D2DNYAC
@D2DNYAC 15 күн бұрын
Thanks for watching
@biagio71
@biagio71 16 күн бұрын
My Liebert DS unit like yours has the same alarm “compressor overload 2”. The fuse #2 keeps blowing out. Avery time I start the unit and compressor #2 contactor closes the fuse blows out. If I manually push the compressor contactor the compressor runs and works fine. What do you think makes the fuse blow out all the time. Your help is really appreciated
@D2DNYAC
@D2DNYAC 15 күн бұрын
Check contactor coils and liquid line solenoids coils
@biagio71
@biagio71 15 күн бұрын
Wow. You’re the best! I don’t have words to thank you. It was the solenoid valve coil that was causing the short. I really appreciate your help.
@matthewh9585
@matthewh9585 16 күн бұрын
Had to replace about 15 contacters today…really annoying how Lennox likes to overload them with wires. How expensive is it to put another relay in bro. Why does the compressor, cfm, crankcase heater, etc all need to be powered off 1 contacters. Every pole has atleast 5 freakin wires on it ON BOTH SIDES. WHY BRO I CANT GET MY SCREWDRIVER BACK THERE AND EVERYTHING IS WELDED TOGETHER FROM ARCING
@D2DNYAC
@D2DNYAC 16 күн бұрын
😂😂 I feel your pain brother
@badassbinner
@badassbinner 17 күн бұрын
Michael J Foxed himself.
@D2DNYAC
@D2DNYAC 16 күн бұрын
M J foxed ?
@fatbass311
@fatbass311 17 күн бұрын
How about mounting the contactor first then connecting stake ons and line/load
@D2DNYAC
@D2DNYAC 16 күн бұрын
Not a bad idea
@lorenzo42p
@lorenzo42p 17 күн бұрын
easier with a manual screw driver
@D2DNYAC
@D2DNYAC 16 күн бұрын
Definitely
@mwdub02
@mwdub02 17 күн бұрын
That last screw never fails to screw us over 😂
@BluTooph
@BluTooph 17 күн бұрын
Ingenious....Thank You Mate!!!!!!!
@D2DNYAC
@D2DNYAC 16 күн бұрын
Thanks for watching
@Jobychayan4085
@Jobychayan4085 18 күн бұрын
Have any software for this unit
@D2DNYAC
@D2DNYAC 18 күн бұрын
Nope
@Jobychayan4085
@Jobychayan4085 18 күн бұрын
Which converter rs485
@D2DNYAC
@D2DNYAC 18 күн бұрын
Yes Rs485 to usb
@Ismail-si3mv
@Ismail-si3mv 18 күн бұрын
Phfon
@D2DNYAC
@D2DNYAC 15 күн бұрын
Thanks for stopping by
@washingtonbajan8205
@washingtonbajan8205 20 күн бұрын
Awesome
@D2DNYAC
@D2DNYAC 20 күн бұрын
Like and share
@buggedmechanics
@buggedmechanics 20 күн бұрын
So gone are the "beer can cold / just top it off" days, 😄
@D2DNYAC
@D2DNYAC 20 күн бұрын
Definitely 😂
@D2DNYAC
@D2DNYAC 20 күн бұрын
Like and share
@MarkThrive
@MarkThrive 20 күн бұрын
Loved working on RTU's until it poured rain and got gusty! Wished the doors opened as a canopy overhead. Great video brotha! Be safe! 🙏Namaste
@D2DNYAC
@D2DNYAC 20 күн бұрын
Thank you for stopping by
@D2DNYAC
@D2DNYAC 20 күн бұрын
Like and share
@mattwoodbridge7924
@mattwoodbridge7924 21 күн бұрын
The tim pros kinda let me down... ive rocked them for 10+ years, and now i rock keen utility.
@D2DNYAC
@D2DNYAC 20 күн бұрын
Really , how do you feel about Brunt’s?
@mattwoodbridge7924
@mattwoodbridge7924 20 күн бұрын
@D2DNYAC I've never had a pair, but they're cheap. I'll stick with my Keens. Next pair, I might get Thorogoods.
@mattwoodbridge7924
@mattwoodbridge7924 20 күн бұрын
@D2DNYAC I also should say, that my last pair of Timberland pros were purchased off of Amazon, so they might have been cheap knockoffs. 🤷‍♂️
@icq9988
@icq9988 21 күн бұрын
If I got both bad high and low pressure switches , is there a way to connect them altogether? Thanks
@D2DNYAC
@D2DNYAC 20 күн бұрын
I don’t understand what you are asking my friend
@seldomnseen
@seldomnseen 22 күн бұрын
I got one I work on 20 compressors. Cooling tower and geothermal, plus does the domestic hot water. Really cool to see it cool and heat or vice versa at the same time.
@D2DNYAC
@D2DNYAC 21 күн бұрын
None heatpump is correct? Heating is provided by condenser water, while the well water provides a constant heat load for the evaporator
@D2DNYAC
@D2DNYAC 21 күн бұрын
I did lots of work on one practically brought it back to life 12 modules 24 circuits , which is really an amazing piece of engineering