FUJITSU MINI SPLIT TROUBLESHOOTING

  Рет қаралды 29,514

D2D NY Real World HVAC Simplified

D2D NY Real World HVAC Simplified

Күн бұрын

Пікірлер: 47
@erikcable1755
@erikcable1755 Жыл бұрын
next guy on the roof. he pulls the gas out and weighs it. wow, finds the unit with an extra 5 lbs of gas in it. now, he reads the factory charge and refills the unit. he sells the owner some 410a and pays for his time. money well spent here...
@D2DNYAC
@D2DNYAC Жыл бұрын
Thanks for watching
@connorkurant5591
@connorkurant5591 Жыл бұрын
All those lines should be insulated... its already metered refrigerant as it leaves the outdoor conenser
@D2DNYAC
@D2DNYAC Жыл бұрын
Agreed
@catgrows1097
@catgrows1097 2 жыл бұрын
this was great. thanks. please come to my town my tech is terrible.
@D2DNYAC
@D2DNYAC 2 жыл бұрын
😂 thanks for watching
@lizak3636
@lizak3636 2 жыл бұрын
Thank you. This is a very educational video that you posted. I have a similar system installed over a 10 years ago. I was going crazy to locate 4 (error) LEDs residing on the main board inside Fujitsu Condenser unit which could be spotted only if looking inside the unit at certain angle. One of mine (indoor) evaperator units I have a trouble with stopped working properly. When It starts on heat, set point 88F, fan speed set to high. It only outputs room temp. at very low fan speed. Two other indoor units of the same condenser unit are working fine. The error code LED 1 is Flashing ones. I have a 4 Zones condenser unit. Zone A is not connected, there for LED 1 is showing comm. failure. The unit I have a problem with is on zone C. Noting was changed from the moment my system was installed. Have you ever run into a similar problem with a Fujitsu split system? What do you recommend? Thank you in advance.
@D2DNYAC
@D2DNYAC 2 жыл бұрын
It appears that the EEV / LEV ( located in the outdoor unit) for the particular zone is bad , this I have experienced before!
@D2DNYAC
@D2DNYAC 2 жыл бұрын
I solved this by moving the connecting pipes/ refrigerant lines and wires to the unused zone and it worked fine.. you can also swap around the eev/lev coils however if it's not the coils that's bad then it still won't work!
@JohnSmith-oj3uu
@JohnSmith-oj3uu 2 жыл бұрын
If you are changing in the winter do you want it on heat mode on max so the inverting working at full load?
@D2DNYAC
@D2DNYAC 2 жыл бұрын
Charging???
@D2DNYAC
@D2DNYAC 2 жыл бұрын
I would say yes
@flameoflifecreations8959
@flameoflifecreations8959 3 жыл бұрын
The only right way is to recover and weigh in the factory charge.
@D2DNYAC
@D2DNYAC 3 жыл бұрын
I agree 👍
@kastenusa
@kastenusa Жыл бұрын
My suction temperature is 48F. Suction pressure is 94PSI. 70 outside. Supply 46.6F. Return 67.6F. Delta T 21F. Unit was low. I added 2.65 lb of 410. But low side would not go to 120psi. Mini split in a full blast. Any ideas? Thank you!
@D2DNYAC
@D2DNYAC Жыл бұрын
Most likely because of low load conditions, your return air is 67.6F so the EEV or LEV is closing down ! I wouldn’t add anymore refrigerant! What was your temperature set point?
@kastenusa
@kastenusa Жыл бұрын
@@D2DNYAC I just turn it on AC on max and Fan on high speed. Couldn’t find test mode on this mini split. I feel like I over charge it. Total superheat is 20F. Target by conditions is 27F. If it’s -+2 degrees charge is correct. In my case total > then target by 7. I think it’s over charge.
@Drak7282
@Drak7282 15 күн бұрын
You over charged it. If you have a 20 degree delta you are good. Mini splits modulate, you weren’t running at full load conditions. Turning the fans speed up isn’t enough on a 70° day, system design is 95° ambient OA. First thing you do with a mini splits is check delta with high fan, if delta is good the system is good. Gauges on a mini split is to be avoided at all cost.
@barbaracarr6002
@barbaracarr6002 Жыл бұрын
Why would all three lights be flashing and I was unable to shut it off with the remote?
@D2DNYAC
@D2DNYAC Жыл бұрын
I don’t know the answer to that, however I would assume there’s some form of error, then i would power cycle see what happens, try get a hold of the manuals that will tell you
@zetnompainting
@zetnompainting 3 жыл бұрын
Great job man, thnks for the lesson
@D2DNYAC
@D2DNYAC 3 жыл бұрын
Thank you for stopping by
@nyikayaramba7460
@nyikayaramba7460 2 жыл бұрын
Good but where is your charge scale if the system is lower on gas .less than full charge recover all the refrigerant and charge the system according to factory charge
@D2DNYAC
@D2DNYAC 2 жыл бұрын
Indeed however if you know the numbers you can come very close to a proper charge without that means
@D2DNYAC
@D2DNYAC 2 жыл бұрын
Thanks for watching
@rogerf3622
@rogerf3622 3 жыл бұрын
Wow all the insulation is gone on the refrigerant lines.
@brandoseph1446
@brandoseph1446 Жыл бұрын
Wow you should look at 95% of equipment in the world lol
@peled1
@peled1 3 жыл бұрын
I see you are from ny are you looking for techs/ installers?
@D2DNYAC
@D2DNYAC 3 жыл бұрын
@peled 1 gaming are you a pro or beginner?
@peled1
@peled1 3 жыл бұрын
@@D2DNYAC what would you consider a pro? meaning I can go on calls myself well if that's the case then somewhat yeah mostly with mini splits I can go on calls myself but when it comes to central air I don't have as much experience with that I am young though so if I told you my age you wouldn't believe me though that I know what I'm talking about that's why I ussaly ask for a hands on interview if possible to show you what I know
@D2DNYAC
@D2DNYAC 3 жыл бұрын
@peled1 gaming did you watch this video? kzbin.info/www/bejne/Z2S3n32Dgrpjd9U
@peled1
@peled1 3 жыл бұрын
@@D2DNYAC no but ill watch it tonight when I get home :)
@alikhalid76dxb
@alikhalid76dxb 3 жыл бұрын
Dee tooo deee en y We love this song
@airmechanical7163
@airmechanical7163 3 жыл бұрын
Good video !
@stevencarrillo3615
@stevencarrillo3615 3 жыл бұрын
Thanks that helps me a lot
@jsaaal123
@jsaaal123 3 жыл бұрын
Why wouldn’t you do it the right way by removing the refrigerant and following the correct process. Cmon charge the customer accordingly and do right by the customer .
@D2DNYAC
@D2DNYAC 3 жыл бұрын
@jsal707 tell us how you would do it please!!! I solved the client problem in the most effective way saving 💰 & ⏲
@brisafresca1175
@brisafresca1175 3 жыл бұрын
This is just guessing, recover and fill factory + line length.
@D2DNYAC
@D2DNYAC 3 жыл бұрын
I agree so it would appears! 😂, however some calculations was involved coupled with years of experience my friend
@jmesarch
@jmesarch 2 жыл бұрын
Man you don't use the same charging techniques on Fujitsu Mini Splits that you would on standard Ducted systems .... the tech info from Fujitsu tech support will tell you that their system has low pressures in the line set that is usually (from memory) 120 psi where a standard ducted system has extremely high pressures
@D2DNYAC
@D2DNYAC 2 жыл бұрын
Thanks for watching
@c.b.6127
@c.b.6127 2 жыл бұрын
Here is some sound advice to help all. Don't buy fukitsu garbage ever again. They are shite with constant problems. NEVER AGAIN.
@D2DNYAC
@D2DNYAC 2 жыл бұрын
lol
@D2DNYAC
@D2DNYAC 2 жыл бұрын
What did they do to you?
@c.b.6127
@c.b.6127 2 жыл бұрын
@@D2DNYAC Hi, The Units I bought in three different locations went south on me. Exorbitant pricing for repairs and a nonsensical troubleshooting system that is ridiculous and non user friendly. I would never buy another Fujitsu product again. I should have used due diligence and seen ahead of time the countless bad reviews and experiences other customers have had. Shame on me for not checking first I guess.
VERTIV LIEBERT PDX PRECISION COOLING SYSTEM
32:29
D2D NY Real World HVAC Simplified
Рет қаралды 20 М.
How to Work on Mini Splits?
30:30
Taddy Digest
Рет қаралды 131 М.
24 Часа в БОУЛИНГЕ !
27:03
A4
Рет қаралды 7 МЛН
"Идеальное" преступление
0:39
Кик Брейнс
Рет қаралды 1,4 МЛН
Sigma girl VS Sigma Error girl 2  #shorts #sigma
0:27
Jin and Hattie
Рет қаралды 124 МЛН
MINI SPLIT Parts Explained! Understand What They Do!
19:31
AC Service Tech LLC
Рет қаралды 684 М.
Mini Split Not Heating Leaking Refrigerant
11:02
Taddy Digest
Рет қаралды 95 М.
How to troubleshoot a mini split air conditioner
15:52
Nor-Cal Refrigeration & H.V.A.C
Рет қаралды 103 М.
Unit is not Cooling, No AC Service Call
12:37
HughesMan HVAC
Рет қаралды 10 М.
TROUBLESHOOTING MITSUBISHI CITY MULTI MINI SPLITS
17:39
D2D NY Real World HVAC Simplified
Рет қаралды 7 М.
10 Reasons Why A Mini Split Flare May Be Leaking Refrigerant!
18:15
AC Service Tech LLC
Рет қаралды 758 М.
Fujitsu ductless mini split - how to use and features for a new user (Link in description)
14:32
Trolley Brothers Heating, Cooling, and Fishing
Рет қаралды 31 М.
富士通冷气清洗 Fujitsu aircon service
12:01
王同学的Aircon_homes
Рет қаралды 99 М.
Crucial Knowledge To Heat Pump Troubleshooting
14:15
Jersey Mike HVAC
Рет қаралды 65 М.
24 Часа в БОУЛИНГЕ !
27:03
A4
Рет қаралды 7 МЛН