Daikin Ac Signals are Dead (U4 Error), 2 & SIG Terminal Only 220V

  Рет қаралды 13,332

Forever Tech Hindi

Forever Tech Hindi

Күн бұрын

In this video, we'll be taking a closer look at the Daikin Inverter AC U4 error code and what could go wrong when trying to repair and fix the PCB board it. If you're experiencing this error code on your Daikin AC unit, don't worry - we've got you covered. Our expert technician will walk you through the steps to diagnose and repair the U4 error, so you can get your AC unit up and running again in no time. We'll cover common issues that can cause the U4 error and tips and tricks for troubleshooting and fixing the problem. Whether you're a DIY enthusiast or a professional HVAC technician, this video is a must-watch for anyone looking to repair the Daikin Inverter AC U4 error. So please sit back, relax, and let's get started!
💡 Join Us On Patreon 👉 bit.ly/3vMga6S
💡 Subscribe To Get All FREE Videos 👉 bit.ly/3MMozxd
_____________________________________________________________
💡 Subscribe to Forever Tech Shorts Channel 👉 bit.ly/3gL5vQz
Social Media Links
💡 Facebook 👉 bit.ly/3hTPHvY
💡 Instagram 👉 bit.ly/3oJcwDm
💡 Twitter 👉 bit.ly/3atkbRl
****************************************************************************************************
For Business Inquiries and Promotions, please get in touch with Us On Email: robin.nadeem@gmail.com
****************************************************************************************************
#Forevertech #ac #daikin #u4 #pcb #repair #fix #error #code

Пікірлер: 21
@VIP.EMG.
@VIP.EMG. Жыл бұрын
2:20 buradaki ölçüm de 2-SİG DC de 24 volt okudum, AC de sıfır volt okudum. İç ünite kartından mı dır? Sorunum. Klimam Daikin 9000 BTU
@madhureddy3654
@madhureddy3654 Жыл бұрын
Very nice. Clarification. .sir. Westar. 5 star. AC. Mara. Ghar. Pay hai. Sir. Cooli ng. Every. Thing. Is. Fine. But. 9Amp. Power. Leraha. Hai. Power bill. Badgaya. ? Kya. Karu. ? Any solution. ? About This. Problem. Pls. Tell me. Sir. From. AP. State.
@Shahidkhan-wz8sj
@Shahidkhan-wz8sj Жыл бұрын
Drill machine wali pipe flaring tool Sahi hoti hai kya please ek bar btao please Ek video
@hasantahir6556
@hasantahir6556 Жыл бұрын
I have to buy dc inveter ac 1.5 ton. Kindly suggest which ac to buy. Tcl vs pel vs dawlance. Which ac to buy. Kindly tell the model also. Which company has less complaints
@hafizmuhammadatif946
@hafizmuhammadatif946 Жыл бұрын
Nice sr
@attiqe-cv6on
@attiqe-cv6on Жыл бұрын
Sar ap ke shop kedar ha
@XPERIMENT404
@XPERIMENT404 Жыл бұрын
Good information sir
@raoamarjeet5473
@raoamarjeet5473 Жыл бұрын
Guru ji inverter ac main Comparetor/operational amplifier ic pcb main kaam kase karti hai aur inko kon-kon si pin pr kitne voltage aane chaye, aur ye voltage hum kase calculate kr sakte hain ki voltage sahi hain ya nhi, under load/over load, current sense circuit main kase kaam karti hain Inki working ko thoda acche se samajo guru ji
@martinsutton7120
@martinsutton7120 Жыл бұрын
I have a problem. Midea 18K Btu 2 zone. Indoor units show P4 Outdoor shows P6. It will cool fine for several hours then stops. Ten will cool again. I have done all the checks that Midea says to do. All seem to pass. I really need that UVW tester you showed. I have seen several tests that you recommend That I will try to do. Reactor ground test as an example, as well as the IPM voltage test when powered. Maybe you have some insight to my issue? I hope so! Thank you so much for these videos! No one in American seems to have the knowledge how to fix these.
@ForeverTechHindi
@ForeverTechHindi Жыл бұрын
The p4 is the compressor drive error, mainly the problem is with the outdoor motherboard, Or something else could be faulty too. It will need a proper troubleshooting.
@ForeverTechHindi
@ForeverTechHindi Жыл бұрын
If the motherboard gets faulty, repair it through a certified tech. Or I would recommend to send it to northrigde fix, which is an electronics repair shop in america, hopefully he will be able to repair the motherboard. Visit his channel on KZbin.
@martinsutton7120
@martinsutton7120 Жыл бұрын
@@ForeverTechHindi THANK you!!!
@martinsutton7120
@martinsutton7120 Жыл бұрын
@@ForeverTechHindi By mother board you mean control board, Not IPM board? I swapped the "Control Board" out same error. P4 inside P6 on compressor unit outside. I will send one board to Northridge.
@shakshiairconditioner2727
@shakshiairconditioner2727 Жыл бұрын
Sir namskar sir pta chart kese read karein
@rameezyousafofficial4449
@rameezyousafofficial4449 Жыл бұрын
Sir ap sa unit repair karwana ho kasay bajain whatsap pa ap reply nai datay kasay ap sa rabta karain.. sharp jtech 2 ton ka ac ka brand new one month use hwa error code da raha compresor 4 min chalta ha trip kar jata our 8 sa 10 bar trip karta phir error aa jata
@XPERIMENT404
@XPERIMENT404 Жыл бұрын
Goo
@laduram_ji_nayak
@laduram_ji_nayak Жыл бұрын
Sir mujhe bhi kam ap se
@mdzameelansar7102
@mdzameelansar7102 Жыл бұрын
Inverter h
@bolangpwt9715
@bolangpwt9715 Жыл бұрын
Pake bahasa planet mars jadi saya gak tau 🥶
@XPERIMENT404
@XPERIMENT404 Жыл бұрын
Call me sir
Daikin inverter Ac PCB P4 error repair | Qphix appliance repair |
28:30
Qphix Institution
Рет қаралды 33 М.
龟兔赛跑:好可爱的小乌龟#short #angel #clown
01:00
Super Beauty team
Рет қаралды 59 МЛН
ROSÉ & Bruno Mars - APT. (Official Music Video)
02:54
ROSÉ
Рет қаралды 65 МЛН
Wait for the last one 🤣🤣 #shorts #minecraft
00:28
Cosmo Guy
Рет қаралды 7 МЛН
إخفاء الطعام سرًا تحت الطاولة للتناول لاحقًا 😏🍽️
00:28
حرف إبداعية للمنزل في 5 دقائق
Рет қаралды 82 МЛН
Daikin U4 Troubleshooting
24:37
Christopher Brown
Рет қаралды 599
Daikin Mini Split AC Motherboard Fix For U4 Error (Modification)
10:00
Forever Tech English
Рет қаралды 22 М.
Haier Dc Inverter Ac 1 Ton/1.5 Ton/2 Ton PCB E7 Error Code Repairing
16:44
Forever Tech Hindi
Рет қаралды 37 М.
U4 error Daikin inverter AC communication
15:50
Electric Locha
Рет қаралды 30 М.
龟兔赛跑:好可爱的小乌龟#short #angel #clown
01:00
Super Beauty team
Рет қаралды 59 МЛН