Thanks for showing that you put BOTH of the generator hot conductors through the CT to measure the entire generator output for 240V generators! I am doing this project at home and I forgot I could do that. Thank You!!!
@58Alpha4 күн бұрын
No worries. It doesn't make much sense to me to separate it for generator usage. I want to know the total amount of load is on the generator anyway. Thanks for watching!
@TheWilferch17 күн бұрын
Hint for others ( 7:00-7:20)..... adding wire length to the CT's ( current transformers....the "doughnut")....is typically not a problem, just use same gauge or thicker wire. CT's work by measuring current such that any (very small) voltage drop affect by adding CT wires is of very little influence...... go for it.
@TheWilferchАй бұрын
How do you fit the closure plate on your main panel?....seeing that the new meter panel alongside has 2 wire-tunnel projections placed right over the flange-face?
@58AlphaАй бұрын
I actually made a cut out for it with a Dremel
@WilliamBaran23 күн бұрын
I understand the need for meter hot lead on the breaker to get power, voltage reading. But isn't that 'double tapping' and against code ( doubtful the breakers designed for two wires ) ??? I guess only other option is two new breakers for A and B phases.
@58Alpha23 күн бұрын
What is double tapping? The breaker was all installed before I moved in. I'm sure it's to code
@WilliamBaran23 күн бұрын
@@58Alpha Double Tapping is having Two Wires under one screw of the breaker. Only a few breakers are designed for more than one wire.
@TheWilferch2 ай бұрын
Nice install.....especially since you are "reading" each 120V leg of your city 240V supply. Question: now that you are monitorong the 2 x 120V legs on city power......why didn't you use a duplicate set of 2 meters for the generator? In my view, the "health" of each individual generator 120V leg might be more important to check if it's good....compared to the need to check each 120V leg of city power.....no ?
@58AlphaАй бұрын
That's a good point but I figured I'd want to know the total voltage at the generator and I also don't use the generator every day.
@josephasuncion316325 күн бұрын
Good to know that connecting the generator ctu to both wires would display total watts for the generator.
@58Alpha25 күн бұрын
@@josephasuncion3163 Yeah, I mean the I care more about the total watts from the generator since it's rated for an overall rating of 7500W.
@JALBANESE523 күн бұрын
Nice job putting it all together. Question: In your setup with both generator lines passing through a single transformer, are you sure you're measuring the total current? It seems more likely that you're reading the net current, not the sum of the currents from both lines. Since the currents in the lines oppose each other, the transformer would show the difference between them, not their combined total. IOW, the neutral wire carries any imbalance between the line currents, so when both line wires pass through the transformer, it measures the net difference, not the total current.
@58Alpha23 күн бұрын
@@JALBANESE5@JALBANESE5 probably but I'm mostly concerned with wattage because I don't want to exceed the wattage of my generator. I haven't seen it in action really since I haven't used the generator in a situation yet.
@josephasuncion3163Ай бұрын
What size wire did you use for powering the meters?
@58AlphaАй бұрын
I used the standard electrical wiring that is used in the electrical box and throughout the house that feeds your outlets and switches. Should be 14 gauge, 14-2.
@itninja95034 ай бұрын
You really should move your 100A Breaker to the top of your panel and install a Generator Interlock Kit. That is required as code everywhere I have ever checked, as well as will ensure you don't hurt someone by forgetting to kill you mains when you use this.
@58Alpha4 ай бұрын
I do have a generator interlock kit. It's on the faceplate of the panel cover. You cannot see it when the faceplate is off.
@GlenWilliams-o5l25 күн бұрын
Great video, thanks! One question...where did you wire the power source for the bottom CT measuring the generator power?
@58Alpha25 күн бұрын
The white to the normal usual bus bar, the black from the circuit breaker that the generator is on.
@GlenWilliams-o5l25 күн бұрын
Thank you!
@homayoonjoudat3713Ай бұрын
Nice job! but could we get the power for the monitors from sources other than the main circuit breaker panel ... like from the plugs on the wall?
@58AlphaАй бұрын
From an individual plug? That's gonna be different since many outlets are on the same circuit, and you could check the whole circuit that runs the plug you are curious about. Other than that, I'd recommend something like this which I use for individual plugs: amzn.to/3SebDEG I've used this for a couple years now and it's been awesome.