Great content! I don't understand how this doesn't have a million views.
@TacoHVACtv2 жыл бұрын
Thank you, Levi!
@abacojack13 Жыл бұрын
Question. what controller would I use and how would it be wired if I had 4 zones (4 circulators) and on each zone manifold I wanted to use actuators to split the zone into separate sub-zones each with its own thermostat. can you do a video on that?
@TacoHVACtv11 ай бұрын
@abacojack13 Thanks for watching Taco Tuesday, greatly appreciated. There are several ways this wiring can be completed. The first is if the manifolds are remotely located. I would install a zone valve controller (ZVC) at each manifold location, thermostats and actuators wired at that location. Then take the end switch wire from each ZVC and bring it to the mechanical room where the circulators are. At that point, you would need a switching relay (SR) to handle the 4 circs. That end switch wire will then go to the TT terminal for the corresponding circ.
@TacoHVACtv11 ай бұрын
The second way is if the manifolds are near the circulators, then you would need a ZVC for each manifold and the corresponding circ would then be wired to the ZVC
@philipwischmeyer63012 жыл бұрын
I am wiring ASCO red hat solenoid valves into aTACO 403. The soilenoid valves have 3 wires: 2 reds and 1 green with a yellow stripe. Will that green&yellow go on 1 or 2, with the reds on 3&4?
@doncassavaugh88842 ай бұрын
Question my SR 506 priority indirect hot water tank is calling most of the time causing temperature to rise up to 150°. Instead of keeping it 120°. I've changed control 3 times. Every one does same thing. Is SR506 bad. Oh I pulled bulb up thinking that would help, it didn't
@TacoHVACtv2 ай бұрын
I have a question, what control did you change 3 times? If you have changed the aquastat on the indirect tank and it hasn't corrected the issue, the next step in troubleshooting is removing the wires from the R and W terminal on the SR506 and see if the light goes out. If the light goes out, then there may be an issue with the wiring in between. That is if you are comfortable with this, otherwise, seek the help of a local professional or get in touch with our Technical Services Department
@curve393Ай бұрын
Great video! Question, one of my 3 zones is a hydronic fan heater (Hot Dawg) and the fan kicks on via a fan control center (white rodgers 90-130). How do i make the fan control center work with the Taco zone valve controller?
@TacoHVACtvАй бұрын
Thanks for watching, unfortunately there is no great way to do that on the ZVC. We have what we call the HAFC controller that can help control the fan, the circulator and such that can do what you want. Take a look herepulse.ly/apkvn3omya
@curve393Ай бұрын
@TacoHVACtv thanks for the reply. I'll check that out. By any chance, could I make zone 3 the hydronic fan heater and tie the low voltage side of the fan control center that I have (the R and W) into the zone 3 pump end switch? So the 24vac R wire would go to the zone 3 pump common connection and the W wire would go to the N/O zone 3 pump connection.
@TacoHVACtvАй бұрын
I'm pretty sure you can, I would have to take a look further. Please contact Technical Services and they will be more that happy to help out. If you were to use the HAFC you could take the XX end switch terminal to Zone 3 TT to get make that work. The advantage of the HAFC is that it will have control over the fan and also a delay to make sure the water is warm in the coil before turning on the fan as well.
@curve393Ай бұрын
@@TacoHVACtv having options is a great thing. Thanks again for the help. I greatly appreciate it.
@dave00282 жыл бұрын
Great video. I will be installing a Buderus G215/6 boiler with a 220v burner. I have the primary pump on the boiler and a secondary pump that will go to my garage in floor heat. I need help with the wiring such as how to wire the Honeywell L7224 aquastat to the Taco SR503-EXP-4 controller etc.
@TacoHVACtv2 жыл бұрын
Hi Dave, thanks for watching one of the Taco Tuesday webinars, we greatly appreciate it. Below is the link to our complete wiring guide, look for your application starting around page 83. www.tacocomfort.com/documents/FileLibrary/100-92.pdf
@AdamAirline Жыл бұрын
Awesome video. Does the SR506 exp have 2 dry contacts? That way I can have my ibc boiler smart board switch between zone heat and IDHWH. Currently with the sr506 I have, if the house is heating using 110 degree water based on the outdoor reset and the idhwh calls for a replenish at the programmed 160 degrees well that then pushes 160 degree water through my home heating at the same time because the circulator pumps don’t shut off because the thermostats are still calling for heat. I’m told the exp is the fix for this because of the two dry contacts.
@TacoHVACtv Жыл бұрын
That is correct, you would need the SR506-EXP, it has the two dry contacts you are looking for.
@dragunov5253 ай бұрын
Hello, very informative video. I have a sr502-4 not being used properly (previous owner bypassed it for some reason) If I just want to run two circulators (no zone valves) do I need to utilize ZC/ZR?
@dragunov5253 ай бұрын
I think I answered my own question by looking at the wiring diagram for the HydroStat 😅
@TacoHVACtv3 ай бұрын
I apologize for not getting back to you sooner but it looks like you found your answer....glad I could help. 🤣
@LiloUkulele Жыл бұрын
I building a closed loop system using a brazed heat plate exchanger. Will have a pump on the tankless WH side and a pump on the hydronic side. What kind of switching relay and thermostat should I use?
@TacoHVACtv Жыл бұрын
If both circulators are designed to turn at the same time, then a SR501 can be used if you are using circs with a total load of under 6 amp power draw. For a thermostat, you can use whatever brand and features you want. It will depend upon the number of wires in the wall that are from the room you are heating and the mechanical room.
@ttucci2152 жыл бұрын
I am attempting to install wifi thermostats on a older version of the taco board. Mine is a taco SR 503. My zones don't have the common wire on each zone. I do see a common and 24v section in the top left corner of the board. My questions are can I use that for my common wire? And if so can I run two thermostats from that one section? It says the transformer voltage is 120vac input. The maximum combined load is 15amps.
@TacoHVACtv2 жыл бұрын
Hello Tony, The wifi style thermostats on a SR 503 panel can be challenging. The quick answer to your question is yes, you can use the top left terminals for 24v power. The second part of this answer there may not be enough power at those terminals to power the controller and those new thermostats. That terminal is designed for smaller power loads. Our suggestion is to use an external transformer to power the thermostats. If you are not sure how to connect or your instructions from the thermostat manufacturer are not sufficient, please contact your plumbing and heating professional and/or Technical Services here at Taco. Thank you
@theplumber5852 жыл бұрын
Hello, I am working on a system with 6 zone valves and a system pump. One of the zone valves is a low temperature in floor bathroom and the rest a copper fintube. The low temperature zone comes off a mixing valve and has never really worked. It should have been controlled by a circulator. I am going to remove the low temperature zone valve and replace it with a circulator. Is there a control that will allow me to wire all of this or will I need to use a ZVC6 or ZVC5 and a SR501 for the pump zone?
@TacoHVACtv2 жыл бұрын
Hello The Plumber, When it comes to a multiple temperature system like this where you need a lower temperature for the radiant floor zone, then yes, you need an additional circulator after the mixing valve, that's why it hasn't worked well. However the Zone Valve Controller can only control one circulator and you already have it used with the 5 zones of copper fintube. So you will need an additional SR501. I hope this helps.
@boundlessintrepiddiscovery7242 Жыл бұрын
is there a max distance that the controller can be from the valves? (//max wiring length?)
@TacoHVACtv Жыл бұрын
I wouldn't go more that 75' with 18/4 wire to the zone valves. However, the beauty of the ZCV-EXP models allow you to install the Zone Valve Controller remotely (close to the zone valves) and then using the Expansion terminals ABC, you can daisy-chain from one controller to the other.
@tedcolarusso44062 жыл бұрын
In the 4 zvc examples, does dhw always need to be set as priority? How can 2 circulators (system + dhw) be wired without dhw priority, allowing heat to continue running with a dhw call?
@TacoHVACtv2 жыл бұрын
Ted, DHW circulators do not need to be setup on the ZVC controllers. Most of the time it is based upon the boilers being used and recovery time of the the DHW tank. If you do not want to use the Priority feature of the controller, you don't have to do anything, the default setting of the ZVC is that that zone operates just like any other.