Delta DVP PLC ISPSoft | Programming/simulating high speed counter & interrupt commands with EasyPLC

  Рет қаралды 22,431

plcgoods

plcgoods

Күн бұрын

Пікірлер: 19
@ganesharvind867
@ganesharvind867 3 жыл бұрын
Very good presentation Syedraja bro.Many things i could understand well because you made easy to understand. Thank you.Enhancement of Audio volume will help a lot when many of us do not prefer to use Headphone.
@plcgoods
@plcgoods 3 жыл бұрын
Wow, thanks for your comment, I am glad you liked the video!
@plcgoods
@plcgoods 3 жыл бұрын
Thanks for compliments, if you have any suggestion to present the videos even better, I would be happy to hear!
@juanfranciscojesushernande3396
@juanfranciscojesushernande3396 2 жыл бұрын
This channel is pure gold, thank you very much. If may I, I would like to add that before executing any step described in this tutorial, double check the PLC model you're using to match the High-speed counter and the inputs it uses. Also, when it comes to using a two-phase encoder (which is my case), a bit (MXXXX) must be used to START the doble counter, instead the phisical input X. For further information you can check out the chapter 2, page 28 on the manual . Thank you!.
@plcgoods
@plcgoods Жыл бұрын
Thanks for your comment. Please, if you have any question about the lesson, be more specific and let me know what exactly the question is.
@JosePerez-ci8gc
@JosePerez-ci8gc 3 жыл бұрын
Thanks, I need your help, how can I synchronize a stepper motor with an encoder? Can you guide me a bit?
@plcgoods
@plcgoods 3 жыл бұрын
Sorry I do not have any practical experience in interfacing Delta PLC with a Stepper motor or an encoder right now BUT I am planning to create a related course in that subject in the future
@hag01alvard34
@hag01alvard34 2 жыл бұрын
Hi, very good information, i have a dude about high speed counter, the HC202, how can reset the input without digital input? Im using the instruction DCNT
@plcgoodsteam8934
@plcgoodsteam8934 2 жыл бұрын
Hi there, I do not understand your question exactly. If you mean how can reset the counter, naturally you can use the reset instruction (for example see the time 10:00)
@plcgoods
@plcgoods 2 жыл бұрын
Hi, how was the result? did it work?
@hag01alvard34
@hag01alvard34 2 жыл бұрын
Hi, yes I tried reset the high speed counter with reset instruction but, don't working, finally i can reset with the instructions DRST
@ahmadkhaldi7705
@ahmadkhaldi7705 Жыл бұрын
thanks a lot
@plcgoods
@plcgoods Жыл бұрын
You are most welcome
@ercankr75
@ercankr75 2 жыл бұрын
tahank you good teycher
@plcgoods
@plcgoods 2 жыл бұрын
You welcome!
@ercankr75
@ercankr75 2 жыл бұрын
@@plcgoods Sir, we are waiting for the continuation, we are waiting for your trainings about full position mm with hsc
@vietnguyen-fy4yh
@vietnguyen-fy4yh 3 жыл бұрын
thanks bro, but i can't do same you C243,please help me
@plcgoods
@plcgoods 3 жыл бұрын
Hi there, maybe the counter names of your PLC are different from mine. Also, pay attention that counters can be used in different methods (1 phase input, 1 Phase 2 input, ...) with different inputs (X0, X1,...). therefore read the counter section of your PLC user manual carefully
@nadeemnader2812
@nadeemnader2812 2 жыл бұрын
Can I use another external input such as X20 instead to count C243 as highspeed counter ?
The Best Band 😅 #toshleh #viralshort
00:11
Toshleh
Рет қаралды 22 МЛН
We Attempted The Impossible 😱
00:54
Topper Guild
Рет қаралды 56 МЛН
“Don’t stop the chances.”
00:44
ISSEI / いっせい
Рет қаралды 62 МЛН
Understanding Arduino Interrupts | Hardware, Pin Change & Timer Interrupts
48:17
The Best Band 😅 #toshleh #viralshort
00:11
Toshleh
Рет қаралды 22 МЛН