It was very useful explanation Thanks a lot for being useful to humanity
@consultor6sigmapyme4 жыл бұрын
Very nice explanation, this is very helpful for my proyect, thank you from Mexico!
@FRO2010fuz Жыл бұрын
Great class, congrats. Thank you so much!!!!
@ahsankaleem26405 жыл бұрын
Hello dear sir i see your vedio very first time and i collact use full information frome your vedio pleas give the sum an other camands explanation of isp soft
@vcc8136Ай бұрын
Can you send link to download the document you used in this document
@rockgangadharan85314 жыл бұрын
Nice video sir i have confused about s3 sampling time putting that one explain
@SuperEngineer025 жыл бұрын
my system 12SE PID Manupulated Output (MV) respon slowly where i need to increase the response time for increase/decrease of analog output. What i should change.
@Ppkportalcom5 жыл бұрын
start from proportional gain proportional gain decides how fast your system respond to a change. Both I and D help to make the response smooth I makes slow and steady wheras D prevents overshoots and fluctuations
@chandansuthar71075 жыл бұрын
Nice Video, good Job.
@prashanthh6984 Жыл бұрын
Hello sir I'm using for first time in delta plc in temperature and humidity chamber program are completed but only problem for not stability in temperature and humidity flectivation.any PID Value available...and pls send your contact details.thank you.
@carloscantillano24185 ай бұрын
Thanks for the video, the MV output does not work. the value is always MV=0 I am working in simulation mode
@pravinranjane72683 жыл бұрын
Can you explain PID instruction is used through WPL soft
@opret21523 жыл бұрын
Nice video, good job.
@sumeetmahale32356 жыл бұрын
How to set output value.. like u hv set pid output value 4000 how is set?
@Ppkportalcom6 жыл бұрын
in the S3 + 6 register you can set the upper bound limit for the MV(Manipulated Variable - PID output)
@sumeetmahale32356 жыл бұрын
Thnx sir.. i hv try... To insert expantion module card for analog output... Bt there is no output genrated from pid output...
@Eletricacom-vn2qu4 жыл бұрын
Bom dia professor, tem como controlar em PID duas válvulas solenóides uma controla a abertura e outra o fechamento
@vaishnavielectration3 жыл бұрын
Sir i m unable to find mv on my pc
@renatocosta71454 жыл бұрын
Muito obrigado pela explicação.
@chickenz46043 жыл бұрын
Hi Sir, Nice Video! I am planning to control Ph meter automatically. But I am using normal valve (On/OFF) for the base and acid valve. Is it possible to use Proportional control by varying the timer value? based on the difference between PH present value and PH target value
@jkeee18003 жыл бұрын
Thank you very much sir
@Shahidhussain-jj3ej5 жыл бұрын
hi how can i pid 2 rely like y0 high temp and y1 low temp like forward reverse motor control valve plz helpe me
@paninivitor5 жыл бұрын
I have a DVP-14SS2 working with and extention DVP-06XA and beggining with a digital button i need to send 20mA in the CH5, the Analog Output. How can i make this? tks
@Ppkportalcom5 жыл бұрын
Use instruction " TO " to transfer values to analog channels
@PIDOtomasyon4 жыл бұрын
Hi, urgent please, is Dvp 14SS-2 support PID function? because not working PID_WM out. I try every thing, but not...
@Ppkportalcom4 жыл бұрын
14SS2 supports PID function
@yeserakkad77185 жыл бұрын
good job keep going
@mohamadajam9375 жыл бұрын
thanks for your feedback we appreciate it very much
@syeswanthkumar4126 жыл бұрын
I have a DVP 14ss2 PLC and a delta temperature controller could u please help to the wiring for PLC and controller , communication between the PLC and pc, controller thanks in advance
@Ppkportalcom6 жыл бұрын
Can I know the exact model no of temperature controller
@syeswanthkumar4126 жыл бұрын
Dtb 9696cv
@Ppkportalcom6 жыл бұрын
does your temperature controller have rs485 interface
@syeswanthkumar4126 жыл бұрын
Yes
@syeswanthkumar4126 жыл бұрын
Please help me to sort the problem
@lccora6 жыл бұрын
I did the same program in SS2, using the simulator, and direct in PLC, but no have result in PID block, no show nothing in D200. and in the monitor, show only in D2000, D2012 and D2013 change 0 to 4000 very fast. whats happen?
@lccora6 жыл бұрын
You commented "Also dont forget to use Retentive range for Settings(s3) of PID", need more some instruction to try?
@Ppkportalcom6 жыл бұрын
for PID I recommend to try with real PLC rather than simulator
@Ppkportalcom6 жыл бұрын
share screenshot of monitor values from d2000 to d2019 hope you put d2000 in S3 of plc block
@lccora6 жыл бұрын
kzbin.info/www/bejne/nKulk2agrseqedE Please, see my screen.
@atharmay6 жыл бұрын
Hi dear... I tried with real PLC but same problem coming with me plz suggest possible causes.
@vaibbhavgodse37025 жыл бұрын
what is command for ADC for delta PLC FOR temp controller
@Ppkportalcom5 жыл бұрын
For making analog to pusle use GPWM instruction
@cervejariauffenberg32525 жыл бұрын
Please do not understand how to configure S3 to work with autotune. literally, what should input S3 look like? Thanks!
@udaykulkarni8989 Жыл бұрын
Can't see vodeo properly Onlt green screen
@xeroki3 жыл бұрын
AAAAAAAAAAAAAAAAAAH AGORA SEM TENDO MANITO KKKKKKKKK