Brilliant! Solved my puzzling over the problem. Very clear explanation from a clearly very experienced plumber. Thank you sir.
@dereton33 Жыл бұрын
You are welcome!
@desmondorourke442 Жыл бұрын
@@dereton33 If I'm not sure which mixing tap is causing the problem, could I fit a non-return valve on the cold feed pipe outside the tank in the attic?
@PawełMatuszewski-o1l4 ай бұрын
Thank You. Two engineers can't fix my problem, after watching You fixed that myself. You are the best!
@dereton334 ай бұрын
No problem!
@psmith3145 ай бұрын
Thanks so much, the video was perfect timing I have just been watching your video from 10 years ago on how to replace a Float Valve in the cold water tank, thank you for your video's helped me out so many times. Love your KZbin channel.
@dereton335 ай бұрын
You're welcome!
@lennykelly99522 ай бұрын
Cheers Al I thought that myself there was water in the hot pipe and there couldn’t be if you know what I mean the cold feed to the cylinder in my house is disconnected valve shut off and blanked as well I also had the cylinder out because I’m getting a new one I immediately thought non return valve.In fairness Al you are the only one who’s covered this.
@dereton332 ай бұрын
Thanks Lenny. Nice to know.
@jamesmcgill931611 ай бұрын
thank you for the info never knew that mixer tap needed a return valve many thanks yet again.
@dereton3311 ай бұрын
No problem 👍
@PawełMatuszewski-o1l4 ай бұрын
Dziękujemy.
@dereton334 ай бұрын
Thanks Paul.
@lennykelly99528 ай бұрын
Al enjoy your videos very informative,can I just say it can be a situation where the water in the cylinder gets too hot.One way to solve this was to turn the pump down on an open system the other is if you have a gate valve on the flow to the cylinder so the heat diverts to the heating.Also could I just say that you should have a ball valve before the non return valve so if there is an airlock on the hot water you can shut the water off take out the non return and replace it temporarily with a small piece of pipe blow it out withe the main at the mixer tap by blocking the spout when it’s back running shut the ball valve off replace the pipe with the non return valve then open the ball valve.
@charliejeffers97787 ай бұрын
Cor we were absolutely panicking Overflow was pumping out the side of the house I was just walking out the door & the mrs was shouting “come back !!! “ It’s was the new mixer in the kitchen I stupidly used the tap & left it in the middle of the hot & cold!after use . We just put the hot water on for 3-4 mins & that stopped it after about 30 seconds. Thank you very much sir 👍
@dereton337 ай бұрын
No problem.
@ComradeBroski2473 жыл бұрын
another problem of an overflowing cistern could also be a rare pinhole or corroded cylinder coil.
@dereton333 жыл бұрын
Thanks comrade.
@pezzaboy3 жыл бұрын
Cheers, very helpful. Explains why it thumps out of the overflow when I leave the sink tap running too long when I'm cleaning my paintbrushes!
@dereton333 жыл бұрын
You're welcome!
@Reprogrammed_By_SEGA5 ай бұрын
Trying to figure out what is going on with the design of my hot water cylinder. It is vented and direct with one element (no gas system in the house) but it has two pipes going into the side of the cylinder one at the top which is the thickest pipe and one at the bottom which is thinner and both run up to the attic. I actually have four pipes in total which look like they run up to the attic, side by side. confusing.
@dereton335 ай бұрын
I would need to see it.
@ratchriat17163 жыл бұрын
found this video very informative and useful.
@dereton333 жыл бұрын
Thanks Ratch.
@bbc20231 Жыл бұрын
Very greatful for your page. I have an overflow pipe leaking, I live in a block of flats. Both my toilets are leaking and running into my pan. Could this still be the reason for overflow pipe leaking?
@dereton33 Жыл бұрын
No .
@bbc20231 Жыл бұрын
@@dereton33 Thankyou for your reply.
@TheSylviarebel Жыл бұрын
Thank you so much. I have constant execcive dripping to the outside. I have replaced the old taps with mixer taps, so I thought maybe it is my problem but I get the dripping all the time. Regardless of the taps being open or not. Could that still be the problem? Thank you very much
@dereton33 Жыл бұрын
Try fitting a non return valve on the hot feed to the mixer tap. Do take a look in the loft and make sure it is not the F and E tank that is overflowing as that means you will need to change the cylinder.
@randomelvis3359 Жыл бұрын
Hi, thanks for the informative post 👍🏻…have an overflow issue in heating roof tank… the ball valve is underwater but seals the flow easily…it does suggest a back flow coming up more than the ball valve failing… would this issue happen if we’ve a bath/shower tap mixer and the taps are left on but in shower position (the shower rose is a push button faucet?
@dereton33 Жыл бұрын
You may have mains back filling up the cold feed. Fit a non return valve.
@mtvoss75953 жыл бұрын
Do you only need the non return valves on the hot pipes on a gravity feed system not on a combi pressurised system ?🤔🤔🤔🤔🤔
@dereton333 жыл бұрын
Yes. no need on combi systems.
@pete801 Жыл бұрын
Hi there. I have a boiler in the kitchen and a cold tank in the loft that only goes to cold water mixer tap in bathroom and sink. The cold pressure is low and when i use the mixer tap i only get really hot water because the pressure of the cold is so low to change the temperature at all. If i have the cold and hot open on mixertap for a long time will the hot push through and up in to the cold water tank in the loft causing overflow???? Thank you. Your videos are life savers
@dereton33 Жыл бұрын
No it will be fine.
@pete801 Жыл бұрын
@@dereton33 I'll have to get up in the loft again then and see what caused it. Thanks for the reply 👍
@aftabjaved2 жыл бұрын
hi there, thanks for very informative video . i replace my Ballcock. but it still drips at nights only i do have 2 mixer taps in bath room + shower. i also have the kitchen sink mixer tape . do i need to put none return valve on all hot water feed .where the mixer are? please advice.
@dereton332 жыл бұрын
Yes, but before doing that it but it might be a good idea to check it is not the F and E tank that is overflowing, as that means your hot water cylinder has holed through the inner coil.
@michaelbenton1737 ай бұрын
So I have an overflowing header tank, the cold feed tank isn’t getting up to the overflow so it’s something else. Your explanation makes sense but!!! I haven’t got new taps. We have 2 showers but with mixers and the kitchen sink has a mixer and our en suite has a mixer. Is it possible that one of the mixers isn’t shutting off properly?
@dereton337 ай бұрын
Yes and also they may not have non return valves fitted.
@michaelbenton1737 ай бұрын
@@dereton33 so, I have been keeping an eye on the level, and it is rising. I water coming from the big cold feet tank and I put a clear plastic cup with the half bottom cut out from the pipe that over hangs the small tank and that was dry. So I think it must be coming from the hole at the bottom of the tank. So what does that mean??
@aftabjaved2 жыл бұрын
Thank you for your quick reply . it is the big Black tank in the Attic.after watching your Video i changed the Ballcock Valve . but it still over flow at nights. is there a video by yourself to check the hole in hot water cylinder inner coil? ( this is copper cylinder in the shower room) your help is greatly appreciated. thanks
@dereton332 жыл бұрын
I have no video on that, but, It will be the small F and E tank that will be overflowing not the Main large tank. It should be located next to it.
@billyelliott6525 Жыл бұрын
My problem doesn't seem to be covered. I have 2 tanks, large one to fill the cylinder and a small one for the hotwater/heating boiler..... small tank over flowing after a couple of days after jugging out water to reduce the level, even with the supply to the ball cock isolated....... it is a fully pumped system and a gas boiler (not combi obviously)...... so how is the small boiler/heating header tank getting water to over flow?
@dereton33 Жыл бұрын
The inner coil of your hot water cylinder is holed.
@valmoney88674 ай бұрын
Hi thanks for that...can the same problem occur with individual taps (no mixer taps)? or could shower feed cause it to happen?
@dereton334 ай бұрын
Not with individual taps but it could with a shower mixer.
@valmoney88674 ай бұрын
@@dereton33 thanks my shower has a single cold water feed...regards
@lascar483 жыл бұрын
Great tip Al.
@dereton333 жыл бұрын
Thanks 👍
@aftabjaved2 жыл бұрын
no.copper cylinder is on 2nd floor and black cold water tank is on 3rd floor/in the loft or attic
@dereton332 жыл бұрын
O I see. I would still get someone in to look at it for you.
@aftabjaved2 жыл бұрын
Hi Dereton, thanks again. this is the system i have. in basement Free standing Boiler , pump out side and a expansion tank.2nd floor in the bathroom, a copper hot water tank, in the loft a large black cold water tank. there is only 1 tank in the loft nothing els. in the middle of night or in the some evening water rise in the black cold water tank in the lost and stark over flowing.i had chang the ballcock valve in the tank. but it still overflowing. i am planing to put one way valve on hot feed to all mixer tapes.but i am not sure how to find out if i have a hole in coil ( i believe it would be in hotter tank coil ?) any advice will be welcome you inspire me to do it my self or would you advice me to call someone.i live in west yorkshire Halifax.Thanks in advance
@dereton332 жыл бұрын
If the copper cylinder in the loft is higher than your black water tank, then it is pointing towards the cylinder inner coil. I would certainly get some one in to look at it for you.
@imz7693 жыл бұрын
I'm having same problem with a combination direct cylinder could you make a video on it please
@dereton333 жыл бұрын
A direct cylinder cannot make the tank overflow.
@hrhbucket42683 жыл бұрын
Thanks @dereton33, great video yet again. :-) Do the one way valves reduce the pressure on the hot supply (as far as the tap is concerned)? I looked up 1-way valves and there seemed to be single-check and double-check types. The double check seemed to reduce the pressure more. Could you get away with putting just a single valve just above the output of the water tank which would cover all mixer hot taps? Maybe the reason that one would not NOT do this IS because they reduce the pressure; i.e. only put them where needed (on mixer taps).
@dereton333 жыл бұрын
A single check one reduces pressure the least. A valve on the cold tank outlet would force the water up the vent instead.
@byronhall51452 жыл бұрын
I have this problem. Shall I just add a single to the mixer hot tap? Also need to replace my stop cock as well so I'll use your video for that as well 👍
@GodofHellFire19822 жыл бұрын
Recently fitted new radiator, with some minor issues but works fine now. Since doing that, when I put heating on, the overflow pipe from loft drips. It was fine before so must be related. Any help??? Thanks
@dereton332 жыл бұрын
Air in system or some sludge has moved around.
@shaunwilson5360Ай бұрын
Thanks, I thought I was going mad. Changed the ball cock 5 times, even used 2 floats.
@dereton33Ай бұрын
A tough one to crack
@brycemacdonald4621 Жыл бұрын
What it it when there a continuous stream of water coming out of the roof over flow and there n its just continuous n no taps have been turned on.. it like the roof over flow it connected to the mains from the road
@dereton33 Жыл бұрын
The ball valve in the tank is gone.
@brycemacdonald4621 Жыл бұрын
@dereton33 can that be fix or do u have to replace thr tank
@loriAlessiroberts118 Жыл бұрын
Does this mean you could be getting washed in central heating water meant for radiators?
@dereton33 Жыл бұрын
In a word YES.
@kyleregan5143 Жыл бұрын
Hi mate, could this also happen from a faulty cylinder stat as I don’t have the immersion turnt on? Just thought I’d ask however will definitely be fitting NRVs
@dereton33 Жыл бұрын
Yes it is possible, but it would only happen while the hot water was switched on, not when it was off.
@fergiesunited Жыл бұрын
I have that same problem but it's with smaller tank i think it's the heating tank for radiators keeps filling up and oveflows ouside, put a new ballcock on it but after a few hours still fill up and overflows even with the ballcock completely shut off any idea why . Thanks
@dereton33 Жыл бұрын
It is a pinhole in the inner coil of the hot water tank. Only way of fixing it is to renew the tank.
@fergiesunited Жыл бұрын
@dereton33 Thanks we were thinking of changing hot water tank anyway . Our shower pump keeps going on and off our plumper thinks it the hot water tank needs to be changed.
@OmarOmar-ym1bu6 ай бұрын
Well explained Thanks so much
@dereton336 ай бұрын
Glad it was helpful!
@davehewett64583 жыл бұрын
Wont the cold push down the hot pipe to the valve and therefore not let hw through the non return as the cold water the other side of it is at a greater pressure
@dereton333 жыл бұрын
That`s right but it will stop the tank overflow. Only happens with poor quality taps. Also only when mixing hot and cold together.
@davidseddon80682 жыл бұрын
Very helpful - thank you!
@dereton332 жыл бұрын
You're welcome!
@lillydear11122 жыл бұрын
Thank you so much for explanation I'm much happier about the overflow now and that it's going to be easily sorted
@dereton332 жыл бұрын
Great to hear!
@sparephone82282 жыл бұрын
I've got water flowing into the overflow pipe from the loft storage tank. It happens when I turn on the central heating. I had a recent chemical flush done of the radiators. Can this be sorted easily? The plumber thinks it could some sort of blockage from the flush.
@lillydear25592 жыл бұрын
@@sparephone8228 hi what did you do to remedy this in the end ?
@sparephone82282 жыл бұрын
@@lillydear2559 Hi what happened was that when the plumber allowed the cold water storage tank to drain through the radiators , all the junk and sediment got blocked in part of the piping near the hot water tank. So he had to cut that part of the pipe, clear the blockage and re weld in place again. I was initially told by the plumber company they would a pressure gun to clear the radiators after the chemical treatment. Central heating is workin fine now, definately more heat from the radiators.
@simo2992 жыл бұрын
Best thing since sliced bread 🍞
@dereton332 жыл бұрын
Now that`s using your loaf, ha ha.
@nilwatura44362 жыл бұрын
What's the most common cause, just explain it only please? How to solve it if it is due to the most common problem?
@dereton332 жыл бұрын
Inner coil of the hot water cylinder holed.
@loafersheffield3 жыл бұрын
Some fixed spout (not swivel) mixers, particularly bath deck mixers are dual flow. The water mixes in the spout and not the body of the tap. These wont backfill the hot up through the cylinder and tank and end up pouring out of the warning pipe. They are like rocking horse poo; very rare and it's difficult to establish if you have these beforehand, especially if you purchase them online, or from a diy shed. Let's face it, the staff wont know the difference, nor care for that matter. Caveat emptor! Let the buyer beware! Somewhat begs the question. If you have mains water at high pressure and hot water at gravity (low pressure), what's the point of buying and fitting any mixer?
@dereton333 жыл бұрын
Very true Loafer, thanks for the heads up.
@johnkenny78773 жыл бұрын
great explanation cheers
@dereton333 жыл бұрын
No problem 👍
@decwhite95932 жыл бұрын
Wud I be right in saying If the coil was burst in the cylinder it cud also do this
@dereton332 жыл бұрын
Yes but the overflow would come from the F and E tank not the main roof tank.
@kha_24283 жыл бұрын
Would changing my shower mixer cartridge fix this issue?
@dereton333 жыл бұрын
If it is a faulty one yes.
@kha_24283 жыл бұрын
@@dereton33 cheers great videos l!!
@markennyee2 жыл бұрын
Amazing man 👍👍👍👍
@dereton332 жыл бұрын
Thank you so much 😀
@digger80903 жыл бұрын
Hi Al, does it matter which way round the valve goes?
@loafersheffield3 жыл бұрын
There's a directional arrow denominating direction of flow. If in doubt, blow either end. Air will go through one way only too.
@dereton333 жыл бұрын
Thanks Loafer.
@needlesbeckett2 жыл бұрын
Hero 🎉🎉😊
@dereton332 жыл бұрын
No problem.
@paul_my_plumbs_uk3 жыл бұрын
Get a copy of the water regs to pass the time away ⌚⌚⌚⌚
@dereton333 жыл бұрын
Yawn.....zzzzz
@paul_my_plumbs_uk3 жыл бұрын
@@dereton33 😂😂😂
@Colintetts3 жыл бұрын
Please buy a new pen then your drawing will have less ink blobs on the paper