How To Fix Your Low Water Pressure Problem

  Рет қаралды 978,209

Skill Builder

Skill Builder

Күн бұрын

Пікірлер: 355
@aamontalto
@aamontalto 2 жыл бұрын
Your mentioning of the important terms (flow rate and static pressure) as well as their description is VERY MUCH APPRECIATED. You are the first plumber who shows a sound understanding of his trade (profession really) I have ever come across.
@alagappansockalingam8699
@alagappansockalingam8699 Жыл бұрын
Professional plumber .? ( Busi ness man ?)Any way His idea is well come. our house pipe line must able to with Stand high pressure.
@markpowellmp
@markpowellmp 11 ай бұрын
Hi Roger love your plumbing videos I ran a heating contractors for 30 years in south London and always dealing with flow and pressure problems particularly in Balham and Brixton notorious for low pressures sometimes only 1 bar These accumulators solved many problems for me. One add on tip for you, where even one of these devices would improve but not completely, solve a problem, is to fit balancing valves on the supplies to the individual outlets (just a gate valve with the handle removed) Then similarly to balancing radiators, you can restrict restrict the greedy to favour the needy I used to find it was always the showers, usually at the higher parts of the house, that would suffer to some extent sometimes even after a booster. The combination of booster and balancing was needed on some of the toughest nuts I had to crack with very demanding clients in these expensive areas…..
@SkillBuilder
@SkillBuilder 11 ай бұрын
Thanks Mark that is a good tip
@luimackjohnson302
@luimackjohnson302 Жыл бұрын
Brilliant! Thank you for sharing this video! Simple, Clear & Practical with a lot of well defined valuable experience! You sound like my late father who was a carpenter by trade with plumbing experience! I lost him a few years ago at the age of 94 years! Thank you again and greetings from Madang, Papua New Guinea!
@SardonicALLY
@SardonicALLY Жыл бұрын
High end new builds with multiple bath facilities will of course come with all this factored in and kitted out, but of course existing older housing stock can experience issues over time as they put in attic extensions, en suites, and additional wet rooms, so this information is great for people to know.
@DYIIdeas
@DYIIdeas 4 ай бұрын
Your mentioning of the important terms (flow rate and static pressure) as well as their description is VERY MUCH APPRECIATED. You are the first plumber who shows a sound understanding of his trade (profession really) I have ever come across.
@all4heatinggaslimited40
@all4heatinggaslimited40 Жыл бұрын
Hi Roger Thanks for explaining how these boosters work and the pump. The way you explained in every detail in depth and not only that and you went further to explain how to install it. This is the best of the best videos I have seen then other people's videos.
@rogerpullin112
@rogerpullin112 2 жыл бұрын
That 450 litre tank will weigh nearly half a tonne when full so take care where it's sited - a wooden floor may not like the extra load !
@SalamanderPumps
@SalamanderPumps 2 жыл бұрын
Hi Roger. Thanks for your comment. The AccuBoost 450L will weigh 281kg when filled. Depending where the unit is stored, some reinforcement work may need to be done.
@jgregory935
@jgregory935 2 жыл бұрын
Turns out that there 450L does not relate to water stored rather vessel/cylinder size. As half the volume is taken up with the bladder.
@jgregory935
@jgregory935 2 жыл бұрын
Its not 450litre water stored just volume.
@SalamanderPumps
@SalamanderPumps 2 жыл бұрын
@@jgregory935 The vessel size refers to the total volume e.g. 450L, but this is split almost 50:50 air to water. The air is needed to hold the water under pressure. Thanks
@pigswillbepigs
@pigswillbepigs 2 жыл бұрын
@@SalamanderPumps shrinkflasion at its best.
@bobrose7900
@bobrose7900 2 жыл бұрын
Hi Roger, accumulators have been in use for many years in commercial buildings - hotels, pubs, schools and so on. They are very effective. Love all your videos, and opinions!
@SkillBuilder
@SkillBuilder 2 жыл бұрын
Thanks for sharing
@grahamwatts8305
@grahamwatts8305 2 жыл бұрын
Hi just a quick comment, being a building service engineer, I noticed you incoming mains at the start of the video,that your strainer should be positioned on the horizontal, with the filter facing downwards, or on the vertical with the flow going downwards, but never facing upwards as its installed - Im sure manufacturer installation guidance will verify this -see Hattersley valves as a guide. Apart from that, excellent videos and tips. You certainly have trade experience and it shows in your excellent videos and trademanship.
@SkillBuilder
@SkillBuilder 2 жыл бұрын
Hi Graham. I think you are right but I just followed the arrows, I hope. I will check it and get back to you.
@JP-mu5ic
@JP-mu5ic Жыл бұрын
Good spot Graham, was just thinking the same myself. Strainer won’t catch much facing that way!
@andymav3023
@andymav3023 2 жыл бұрын
It’s usually good practice to take a flow rate from a non restricted tap such as an outside tap ….most kitchen taps / basin taps tend to have reduced flow rates these days! Good video roger
@Tom-Lahaye
@Tom-Lahaye 2 жыл бұрын
No issues with water flow and static pressure here, static pressure is between 8,5 and 9,5 bar which is quite high. A pressure regulator is needed to bring it down to 4 bar in the house. For the garden I do have a 22mm pipe run of before the pressure regulator, the tap on that pipe fills a bucket in 10 seconds, so about 50l / min. But there is another advantage to the accumulator, that's if the water main supply fails. There is enough water in the accumulator to get taps and toilets going for quite a time.
@richardneilson
@richardneilson 2 жыл бұрын
I had the same issue - a 15mm main but just over 3 bar pressure. Swapped the cold tank in the loft for 2 x 250L Stuart Turner horizontal vessels. It made a huge difference. Two points to note though: 1. you need to check the pressure at the tank and adjust the air pressure in the bladder accordingly (from memory i think it was about one bar lower than the water pressure. 2. The stored water warms up over time so drinking water isn't as cold. I would recommend fitting a supply to a tap with a non return valve before the accumulators if possible, assuming you've got the pressure and reasonable flow for it.
@SalamanderPumps
@SalamanderPumps 2 жыл бұрын
Hi. Thanks for your comment. You only need to adjust the pressure on unpumped models, but the amount you need to set it by varies depending on the manufacturer so always check the literature. Thanks
@ciscomoto
@ciscomoto Жыл бұрын
Top marks - brilliant explanation throughout
@alagappansockalingam8699
@alagappansockalingam8699 Жыл бұрын
Fantastic idea. Wellcome. Thank u. from INDIA . TN.
@jonchilds1637
@jonchilds1637 Жыл бұрын
Great information - Thankyou! Also reminds me of my disappointment when replacing our bathroom. Knowing we had crap water pressure, I very carefully replaced the hot piping to the bath in 22mm all the way - even using formed bends to reduce resistance - then unpacked the new tap to find the risers had pathetic 8mm bores!!
@markpowellmp
@markpowellmp 11 ай бұрын
You did not waste your time with the 22mm because the resistance is end to end over the entire route and is still lessened by the mainly larger pipe
@markkenyon8760
@markkenyon8760 Жыл бұрын
Very informative. My old Central heating system needs a refresh and the flow is lowish. Great to know about these and I will get the flow and pressure tested to help decide on the best solution for this house. Remove the tanks and Combi seems like a good option now. Cheers Roger
@SkillBuilder
@SkillBuilder Жыл бұрын
Good luck!
@davidbrand5925
@davidbrand5925 Жыл бұрын
The issue (as stated) is that the water main connection was not replaced properly. We upgraded from 1/2” lead to 25mm MDPE and went from about 15l/m to over 50 L/m on our 3.5bar supply (identical pressure before and after as expected). I could run a shower at 15, a garden hose at over 20 with the kitchen tap also running more than a 20l weir cup could handle). Something is definitely wrong that they need additional kit in this house.
@davidbrand5925
@davidbrand5925 Жыл бұрын
I would also love to know what the flow rate is straight out of their MDPE main before the restrictive stop cock, NRV, filter and PRV. I’d be willing to bet it was a lot higher than after.
@doctorpepper1801
@doctorpepper1801 9 ай бұрын
Watching from Louisiana. Amazing work!
@SkillBuilder
@SkillBuilder 9 ай бұрын
Thank you very much!, good to hear from viewers in the USA.
@aaronthrowa
@aaronthrowa Жыл бұрын
Excellent video and explanation. I couldn't help notice that the kitchen faucet handle is dripping...
@SkillBuilder
@SkillBuilder Жыл бұрын
Yes it was dripping but not any longer
@charlespaine987
@charlespaine987 2 жыл бұрын
A side problem you can create with a pumped unit is drawing down “mains” causing other users of “main” to completey lose pressure. Check with water system operator befor installing.
@SkillBuilder
@SkillBuilder 2 жыл бұрын
That is why the pump is limited to 12 ltrs per minute
@keziasarah
@keziasarah 2 жыл бұрын
@@paul_my_plumbs_uk nice....{not}
@jamiefirbank5747
@jamiefirbank5747 2 жыл бұрын
Water regulations state that only 12ltrs per min can be drawn out of the mains, and this is what the manufacturers work with. The get around is that if you “Store” the water with a accumulator, break tanks, cold water storage tank. You can boost it to what ever you want
@muzikman2008
@muzikman2008 2 жыл бұрын
@@jamiefirbank5747 Nowt wrong with that... unless everyone does it at the same time lol... unlikely but hey ho. 😏
@aspetm3846
@aspetm3846 Жыл бұрын
Well done Roger as you explained very well which it was helpful and useful knowledge!!!!!
@michaelp998
@michaelp998 2 жыл бұрын
Here’s a useful tip: Rotate the stopcock on and off twice a year to keep it free. So many are boxed in and totally inaccessible which is why they seize up.
@suttoncoldfield9318
@suttoncoldfield9318 Жыл бұрын
Don't open the stopcock and leave it at the end of the thread, back off a half turn.
@runamonk
@runamonk Жыл бұрын
I fitted one of these at our old house and it worked perfectly. :)
@be462004
@be462004 Жыл бұрын
For how long?
@Bokuma01
@Bokuma01 2 жыл бұрын
Just had a new main moled in for £1100, 3 small holes dug wouldnt even know it's been done. "pressure" issues sorted (well, no change in pressure but flow rate vastly improved). Permanent no maintenance solution worth looking in to.
@boltonky
@boltonky Жыл бұрын
Great video, been considering an accumulator after changing pumps on a tank system (original pump 20 years ago is spec'd less than current pump and the new one can't keep up with 90% of the house now and water blaster sure when under pressure) Technology gets better but not always production.
@allanb52
@allanb52 Жыл бұрын
Maybe you have an answer to the problem in my house in Thailand. 1. It takes almost a week to fill my 50m3 swimming pool. 2. I live on an estate with an undersized main and most houses have a pump and tank, so at peak times we have almost no water. Certainly the shower won't work and we only have a bungalow. 3. We don't have these products here and I found a Mitsubishi WP105 that may solve my problem. 4. If I use a tank that won't solve the filling my pool problem as when the tank is empty I am back to mains flow. 5. Due to the weather, the pool needs filling every four-six months so a week to do it is a pain. Any pointers would be helpful as no one in Thailand can.
@dah1777
@dah1777 2 жыл бұрын
I have sufficient flow and pressure in the house, but since refitting the kitchen and installing a SureStop to make turning the mains off (we had a burst and my wife couldn't turn the stop tap off) the drop in flow is noticeable when 2 or more taps are turned on. This doesn't cause a problem even with the showers so it's not worth changing anything at the moment. What is interesting is that despite the SureStop being 22mm fitting the bore inside is the same as the 15mm version. Would you consider making a video on the pros and cons of these devices? There is no doubt they are useful in an emergency and where the stop tap is difficult to reach (aren't they all) but given that any restriction on the size of the bore will affect flow rate I think SureStop need to change their product.
@Davey656
@Davey656 2 жыл бұрын
I also have a SureStop and have had some flow issues - would too like to see a video on this
@kevinmullin4504
@kevinmullin4504 2 жыл бұрын
Replace the word Surestop with Nightmare! Get rid of it ASAP. I remove them every day of the week. Not only can they reduce your pressure, they are a major source of leaks themselves as they are water pressure operated as you know. As well as that , it will probably not work at all after a few years so don't rely on it. Tip, you may need to turn 2 taps on to get it to kick in. Sorry for the bad news but make sure you have an alternative way to turn water off . 👍
@dah1777
@dah1777 2 жыл бұрын
@@kevinmullin4504 Thanks Kevin. I am just a home owner and so obviously only see one rather than many. I have only had it for just over a year and I do test it every now and then. I did fit a new stop cock with the SureStop to make sure that I had a more permanent way of isolating the water supply because I read that they should not be relied upon for extended periods. Interestingly I have spoken to a couple of plumbers (mainly on the heating side) who they they have never been asked to fit one
@jeffbrassard1268
@jeffbrassard1268 22 күн бұрын
Great explanation very well done. Thank you!
@Autonomous1969
@Autonomous1969 2 ай бұрын
I've had decreasing water flow for years. I fixed it by turning my stopcock off and fully back on. Dirty water then came out of my kitchen tap and the flow rate was as it should be. I had to use a stopcock key with socket and socket wrench to move my seized stopcock key.
@SkillBuilder
@SkillBuilder 2 ай бұрын
I have had that experience myself on some jobs but I am reluctant to adivse it because it is very easy to sheer the head off.
@Autonomous1969
@Autonomous1969 2 ай бұрын
@@SkillBuilder Yes it was in the back of my mind whilst doing it. I just applied pressure until it just gave way. All fixed now and looking forward to my shower later.
@allsearpw3829
@allsearpw3829 Жыл бұрын
Thank you for a grand explanation , just a mere sparks .
@badmofo420
@badmofo420 2 жыл бұрын
Really informative for me thanks! I moved into a house and have what I think is a similar unpumped device in my loft. It only supplies 2 showers and the hot water.
@jamiefirbank5747
@jamiefirbank5747 2 жыл бұрын
Fitted a few of these and they are a good idea. Biggest issue with this install is that he has fitted after the pressure reducer, if fitted before then you put more water in the vessel under a higher pressure making it last longer. Also with a accumulator when it is depleted you go back to mains, with a break tank you loose water untill refilled These use to be TWS before Stuart turner bought them out.
@SalamanderPumps
@SalamanderPumps 2 жыл бұрын
Hi Jamie, Thanks for your comment. The AccuBoost accumulator needs to be installed after the PRV to protect the vessel from fluctuations in mains pressure which could damage the bladder. Only unpumped accumulators would revert to the mains once depleted. When a pumped unit is depleted, the pump will continue to run to deliver a minimum of 12L/min.
@stevecarter8810
@stevecarter8810 2 жыл бұрын
@@SalamanderPumps good clarification. My fitter got hung up on achieving 3 bar on the prv until I pointed out it was there to protect the pump and vessel and we want it relatively low.
@tinytonymaloney7832
@tinytonymaloney7832 Жыл бұрын
If the cylinder is not changing its water very much doesn't that constitute a dead leg? A potential legionella breeding ground if the temperature is nkt kept below 20`C.
@SkillBuilder
@SkillBuilder Жыл бұрын
It is a good point. I don't know the answer but I will empty it every few weeks now. You just have to turn the mains off and let it deplete.
@stevelawrence7111
@stevelawrence7111 2 жыл бұрын
Is that the consumer unit behind your head?
@barkyvonschnauzer2188
@barkyvonschnauzer2188 Жыл бұрын
Thanks for the great info. I think I may have a solution to our problem with our water flow. Personally, I think these should be installed in all homes during the build process. Thanks, Guv'
@WaiKoH
@WaiKoH Жыл бұрын
It solved my problem, 6 bathrooms and over 3 floors. Thank goodness the problem solved otherwise my head will explode
@n13nhb
@n13nhb 2 жыл бұрын
I tried to fix this problem a while back. Had the utilities company round several times, replaced the small bore pipework from the street stop cock to my house etc. The guy from the utilities (after I said I was going to have to fit a pump) said "shouldn't have to fit a pump, it's regulated up the street as the flow and pressure are too high" the never adjusted it for me but its just annoying that the are throttling in for a reason I haven't figured out yet. I still havent installed a pump and just struggled on...
@SalamanderPumps
@SalamanderPumps 2 жыл бұрын
Hi Nathan, the utility provider are required to provide you with around 9l/min to the boundary, however depending on the length of pipe run and the size of the property a pump could be the solution to poor flow you are experiencing. To find out which pump would best suit your system, please take a look at our product selector. www.salamanderpumps.co.uk/product-selector
@be462004
@be462004 Жыл бұрын
Get a powertank!!!
@samsen201
@samsen201 5 ай бұрын
My problem: in the upper floor of house, water comes well of the shower but barely a drop comes out of sink next to it in the same bathroom. Same for a second restroom in the same floor (Flow to toilet siphon is good but barely a drop coming off at the sink to wash hand!). Where could my problem be and I though may be air lock, thus several times cut the water from house main shut off valve in yard and re started with no avid.
@abidnessman
@abidnessman Жыл бұрын
I think this is great, especially if rural. However maybe add some videos with innovation re gray water recovery, rain water capture, and anything that gives a shower user how much water they have used.
@MrPhotoman1
@MrPhotoman1 Жыл бұрын
I heard salamander pumps are not reliable. Stuart Turner pumps are the rolls royce of pumps there not cheap but built to last.
@grahamshillingford8229
@grahamshillingford8229 9 ай бұрын
I have a new problem after fitting a new kitchen sink mixer tap. The hot flow is extremely slow. I followed the fitting instructions to the T & the exchange was successful with the addition of a couple of stop taps & filters positioned correctly but as for the hot flow, well its just shocking. In fact when both hot & cold are on together its probably worse. Like Roger said in the video, is it just how new mixer taps are?
@nattyco
@nattyco 8 ай бұрын
How do your easily measure pressure if you don't have an outside tap that readily fits the gauge? I would imagine it's difficult.
@vijieditzz4035
@vijieditzz4035 10 ай бұрын
.A new faucet (a dual spray switch tap that allows to switch between a strong shower setting, and normal stream setting) is installed downstairs. Whenever the downstair neighbor switches to strong flow setting I hear a high pitched water stream noise in my kitchen. The below neighbor uses the high flow setting quite often in the day, and it affects my ears as I have an ear condition called tinnitus. But it's loud enough that even someone without tinnitus would find it annoying (the nails against chalkboard type of sound)..why the noise is coming, Really appreciate any help, thank you!
@danieldurnin959
@danieldurnin959 2 жыл бұрын
Nice video as always Roger.
@mabdub
@mabdub 14 күн бұрын
Hi Roger, I had a dripping tap in my bathroom and a plumber fixed it but he didn't change the cartridges or seat and springs in the taps. But, the taps did stop dripping. After the plumber left I turned on the taps and discovered that the water pressure in both the cold and hot water taps had noticeably decreased. The pressure is okay but it's not what it was. The water pressure in the second bathroom taps is still strong, the same as it always is. The pressure has only decreased in the bathroom that the plumber worked on. I'm writing to you becasue I can't figure out what the plumber could have done to reduce the water pressure in both the hot and cold taps. Can you think of something he might have done to reduce the pressure? Like I said, he didn't replace the cartridges. Also, I made sure that the water valves under the sink were fully turned to the open position so I know that they are not reducing the amount of flow that I had before the plumber fixed the dripping tap.
@SkillBuilder
@SkillBuilder 14 күн бұрын
This is tricky because the water pressure is not the flow rate so he would have had to put a pressure reduction in there . If he didn't reduce the flow under the basin he may have put a another rubber washer in the bottom of the cartridge.
@mabdub
@mabdub 14 күн бұрын
@@SkillBuilder Thank you for responding.
@dron8776
@dron8776 5 ай бұрын
Where can I buy such a cup-type flow measurement device?
@multipl3
@multipl3 5 ай бұрын
How about turning the main water valve up a bit?
@jangb8806
@jangb8806 Жыл бұрын
My house water pressure is low as when using same time bathroom and kitchen sink . Please advise how to fix them problems.
@franceleeparis37
@franceleeparis37 9 ай бұрын
😂😂… this is why plumbers charge an arm and a leg when you call them…. Ask them to increase water pressure and they build you a new extension to your house
@gecko6355
@gecko6355 9 ай бұрын
I assume the tank is installed prior to the boiler?
@fxly
@fxly 2 жыл бұрын
Most homes have trunk and branch plumbing systems with undersized pipework, manifold plumbing is the way to go.
@roysammons2445
@roysammons2445 9 ай бұрын
Very interesting info Rodger abs well explained 🙂👍
@SkillBuilder
@SkillBuilder 9 ай бұрын
Thanks 👍
@AlexanderNecheff
@AlexanderNecheff Жыл бұрын
Presumably, if you size the tank correctly so water isn't sitting for days, microbial growth isn't an issue, right?
@gabaknegocios
@gabaknegocios Жыл бұрын
where do you buy that. product to measure the flow?
@TheRottiepups
@TheRottiepups 7 ай бұрын
Just wondering if you could help , our down stairs bathroom toilet has water to the sinks but the toilet has no water it just stopped, I’ve checked the on/off valve and there’s no water pressure there, this pipe goes in the floor, and after that I’ve no idea please if you could help it would be greatly appreciated
@SkillBuilder
@SkillBuilder 7 ай бұрын
How have you tested the on/off valve? It is unlikely that the pipe has suddenly blocked. Often we find a bit of debris has washed into the filter, some need cleaning out twice a year, especially if there are old iron pipes in the mix.
@Royosankar
@Royosankar Жыл бұрын
I accidentally bumped into your video and saw that your kitchen design is like mine.
@lksf9820
@lksf9820 Жыл бұрын
At 4.17 you say unfortunately they didn't renew the tapping on the mains, what and where is that?
@SkillBuilder
@SkillBuilder Жыл бұрын
in the road on the water main
@lksf9820
@lksf9820 Жыл бұрын
I can see why they avoided trying to get that changed by the Utilities 🤣
@daveofyorkshire301
@daveofyorkshire301 Жыл бұрын
What can you do with variable pressure. Sometimes its so high the next door neighbour turning on and off can rattle the pipes, other times it's much lower and full is just above a trickle...
@SkillBuilder
@SkillBuilder Жыл бұрын
It seems that you are on a shared main and if the neighbour is using it you don't get enough. Pressure is not the same as flow. You can increase the flow to 12 lts per minute with a pump which fits on the mains inside the house. Measure how much you are getting at best and worst. It is also worth asking your water supplier. I have sometimes discovered a stopcock that was just about open. I love thos jobs.
@daveofyorkshire301
@daveofyorkshire301 Жыл бұрын
@@SkillBuilder I missed a piece of specific information that invalidate this. I have the main water cut off reduced to prevent water ram in the house. I still get very high pressure, but as you say pressure and flow are different. There are obviously differences in the external feed that are translated through a partially closed valve. I always thought either a water ram protection device or a large tank to provide controlled pressure. Both have their disadvantages.
@rapidariff
@rapidariff 2 жыл бұрын
Thank you for you video's' my question is, can I have a unvented cylinder connected directly to my combi boiler to give me constant hot water just by opening the taps, without using a switch to wait for the cylinder to heat the water. If yes does it use a lot of electricity to work. Thank you
@Fr4nkSanchez
@Fr4nkSanchez Жыл бұрын
Can you add a boost tank after the water softener of a well pump? In otherwords, store clean water not directly from the well, did the pressure of the well tank affect it? My problem is when there is a power outage I loose power to the well pump and no water at the house. Do you recommend adding a check valve where the boost tank is connected?
@SkillBuilder
@SkillBuilder Жыл бұрын
There is a check valve required on the incoming main from the well. A large Boost tank will give you approxiamately half its capacity in water. I drain my Boost by turning off the incoming main and letting the tank deplete under its own compression power. Half the tank is water the other half is air and the air will push all the water out of the tank as it is used.
@toml8142
@toml8142 2 жыл бұрын
Is that strainer upside down? Won’t catch the bits on the outside of the strainer?
@SkillBuilder
@SkillBuilder 2 жыл бұрын
it is a Y filter or are you talking about the washer?
@toml8142
@toml8142 2 жыл бұрын
@@SkillBuilder I normally fit strainers the other way so the muck caught on the inside. Or it’s scraped off into the pipe when it’s removed. I may be looking at it wrong,
@pincombe
@pincombe 2 жыл бұрын
that moment when your giant water tank turns into a little tiny one.
@johnmelkonyan1036
@johnmelkonyan1036 Жыл бұрын
Hi there. I live in Los Angeles California. Can you recommend a plumber in my area who can install that unit for me. Currently I have Groundfos EZ boost in my house for very long time and that model was discontinued and I can’t find anyone to service the unit. I will love to replace the unit before it stops working completely. Thank you !
@kazekagegaara2075
@kazekagegaara2075 8 ай бұрын
Bro how about hot water faucet become cold after few minutes?it's called mixing issue? How can solved this issue? Can you help me? Appreciate it thank you
@davidw460
@davidw460 2 жыл бұрын
Hi - sorry but I can’t see how 4 bar pressure delivers only 10l per minute, unless the pipework is partially blocked. Has a flow test at the property meter been done? I get 15l per min with just 1.8 bar.
@SkillBuilder
@SkillBuilder 2 жыл бұрын
static pressure means nothing. You can get 8 bar on a 6mm pipe but it won't give you a decent flow rate. The taps are often restricted to something like that.
@haritpro
@haritpro 2 жыл бұрын
any tips for someone having just 750ml per minute from the mains in another country? how does once increase the flow, what is the best pump? Thanks
@SunnybraeCroft
@SunnybraeCroft Жыл бұрын
Always a pleasure to watch you work!
@SkillBuilder
@SkillBuilder Жыл бұрын
Thanks Hugh
@gandl2123
@gandl2123 Жыл бұрын
Will this work with well? I have to filter sediment out before it gets to that tank? I have 5-10 gpm at the garden hose. I want to pump it into my home and run my home.
@be462004
@be462004 Жыл бұрын
Get a Powertank
@shrenujjain2213
@shrenujjain2213 6 ай бұрын
Will the old pipes not leak because of extra pressure?
@SkillBuilder
@SkillBuilder 6 ай бұрын
They shouldn't leak
@rotaxrider
@rotaxrider 2 жыл бұрын
Can you use this if you got a drilled well with a submersible pump? If got a tank wet similar to this but much smaller
@redd605
@redd605 Жыл бұрын
What is the best book to get a city and guilds in the trade
@greaterbayareahero1401
@greaterbayareahero1401 11 ай бұрын
Was this taken 10 years ago? Now there is an electric pump 1/100 of that size and get a better result for only 50 gbp.
@philipjohn9018
@philipjohn9018 2 жыл бұрын
Hi how do you get rid of air pressure in yr water line
@1hairymelon
@1hairymelon 2 жыл бұрын
Excellent video with great explanation
@SkillBuilder
@SkillBuilder 2 жыл бұрын
Thank you!
@SalamanderPumps
@SalamanderPumps 2 жыл бұрын
Thanks for your comment!
@raycollington4310
@raycollington4310 2 жыл бұрын
That unpumped unit bladder will lose pressure over time. Does the unit have a Schrader valve and can it be repressured with a compressor and what is the pressure. Thanks Roger, I might pursue this.
@SkillBuilder
@SkillBuilder 2 жыл бұрын
Yes there is a schraeder valve on top and you can pump it up with a car footpump.
@simondevial8727
@simondevial8727 2 жыл бұрын
Really useful video - thanks
@SkillBuilder
@SkillBuilder 2 жыл бұрын
Glad you liked it
@rtel123
@rtel123 Жыл бұрын
Bought this house a decade ago. Plumbed by a plumber with no common sense. Good street mains pressure on a 3/4 inch supply. Most houses here reduce the 3/4 to a 1/2 for interior supply by putting in a 3/4 x 1/2 x1/2 tee at the entrance, to feed an outside hose bib at what is also a convenient location. That allows garden watering without reducing inside pressure, because the 3/4 carries about twice volume as a 1/2. This guy reduced to 1/2 at entrance, then ran about 20 ft of 1/2 to a 1/2 tee to feed an outside bib in a very inconvenient location. Also reduces inside flow when watering! Used much more pipe than needed just to make things worse. 50 year old job, so the plumber is too old to ask "what were you thinking?"
@huguespayens174
@huguespayens174 Жыл бұрын
Hi Roger, my water pressure has dropped dramatically…most notable is the garden hose ,it use to be able to stand 3 metre from where you wanted to water…now it is less than metre..any ideas🤔
@SkillBuilder
@SkillBuilder Жыл бұрын
Put your ear to your cold tap and listen. If you hear a noise it might indicate a leak.
@huguespayens174
@huguespayens174 Жыл бұрын
@@SkillBuilder I’ll try that👍
@Tyroneguy77
@Tyroneguy77 Жыл бұрын
Your a jack of all trades Roger. Lol. So how long where you a plasterer musnt been long if your forty years a plumber. Love your videos great help.
@SkillBuilder
@SkillBuilder Жыл бұрын
When did I say I was a plasterer? I have been plumbing for 40 years but in that time I have done a great many other things and take a few sabaticals because plumbing would drive me nuts. If I gave the impression that I have plumbed 5 days a week for 40 years I am sorry. If the sun is shining and I am in the mood I will even do a bit of exterior painting. I have also done a good many loft conversions with my pals.
@domalama8820
@domalama8820 2 жыл бұрын
Thank you for your video. Please tell me how much it cost me to fixed it. Recently plumber charged me £80 just to change two washer. Did i paid him too much? Fixing water pressure how much do i have to pay an arms and the legs?
@SkillBuilder
@SkillBuilder 2 жыл бұрын
The plumber charged you for travelling to and from your home and having the van, tools and knowledge to do the job.
@elliottdebell7783
@elliottdebell7783 2 жыл бұрын
Is there more information on how these fit onto a combo boiler system? I’m a bricklayer not a plumber so might be a stupid question.
@SalamanderPumps
@SalamanderPumps 2 жыл бұрын
Hi Elliott, there's definitely an application for using the AccuBoost to supply a combi boiler or an unvented system. Please take some time to look at page 4 of our installation information on the following link. www.salamanderpumps.co.uk/uploads/AccuBoost%20Installation%20Guide%20(Jul%2022).pdf
@be462004
@be462004 Жыл бұрын
Get a Powertank!!!
@gowanturnbull1208
@gowanturnbull1208 Жыл бұрын
Where in the UK do you see 4 bar in the street?! Thames Water guarantee only 1 bar and can legally drop it to 0.85 without notice. It's so bad that they even dropped the requirement for a break tank....yes you can directly pump a TWA main!
@allmostmedieval
@allmostmedieval Жыл бұрын
Would this boost hot water pressure from a combo boiler?
@SkillBuilder
@SkillBuilder Жыл бұрын
It will but the flow needs to be slowed in order to heat the water.
@kevinolesik1500
@kevinolesik1500 4 күн бұрын
impressive difference ! ...
@bills6946
@bills6946 11 ай бұрын
It would be cheaper to retap the street main tap for 3/4” or, if permitted, 1”.
@chrissanders55
@chrissanders55 Жыл бұрын
Do these units charge as they go? So I’ve seen on the 450l you get around 40ish minutes of pressurised water and they take 40 mins to recharge. If I’m thinking about showers, will it recharge as you go along assuming you only have a say 10 minute shower? If that makes sense?!
@SkillBuilder
@SkillBuilder Жыл бұрын
They do not fully deplete so you need to factor that in.
@yardlimit8695
@yardlimit8695 Жыл бұрын
very interesting, informative and to the point........great job.
@peterconnolly4608
@peterconnolly4608 2 жыл бұрын
However when you want to check the air pressure vessel you do need to empty out ,
@SalamanderPumps
@SalamanderPumps 2 жыл бұрын
Hi Peter, to check the pre-charged pressure in the vessel, isolate the electrics and mains supply, empty the vessel and use a pressure gauge attached to the Schrader valve on top of the vessel. To check the current PSI inside the vessel, there would be no requirement to drain it down. Thanks.
@stevendobson6485
@stevendobson6485 2 жыл бұрын
Hi Roger, thanks for all your videos. Why don’t you do any videos with Robin Clevett anymore ?
@SkillBuilder
@SkillBuilder 2 жыл бұрын
Robin left to start his own channel, based on him, which we helped him set up. He is doing O.K so there is no compelling reason for him to dilute that by doing stuff with us.
@davidbowley8756
@davidbowley8756 Жыл бұрын
Hi Roger can I fit a unit to my combi boiler system thanks dave bowley
@SkillBuilder
@SkillBuilder Жыл бұрын
yes, that is what I have
@davidbowley8756
@davidbowley8756 Жыл бұрын
@@SkillBuilder thank you Roger Dave Bowley
@andybrown169
@andybrown169 2 жыл бұрын
Surely more pressure will use more water , in times of water shortages is this a good idea ?
@SkillBuilder
@SkillBuilder 2 жыл бұрын
Have a shower of reduced duration
@andybrown169
@andybrown169 2 жыл бұрын
@@SkillBuilder Really, is that your reply 🤔
@akan626
@akan626 Жыл бұрын
Wouldn't it be cheaper to replace the 1/2 inch tapping on the main with a 3/4 inch?
@SkillBuilder
@SkillBuilder Жыл бұрын
They won't do it and I am not allowed to
@Lee.Willcox
@Lee.Willcox 2 жыл бұрын
Roger, I can tell by your fridge there that you have your grandkids round a lot ! Or your wife uses those magnetic letters to leave you little love poems. Most probably "Take the bins out", "Shopping at 5pm", "Hang the washing out". Or is that a reflection on why my wife has magnetic letters on our fridge 🤔😆🤗
@SkillBuilder
@SkillBuilder 2 жыл бұрын
Hi Lee Yes it is the grandchildren, my wife has given up leaving me messages especially of love and she takes the bins out and mows the lawn. Also for me the secret of a happy marriage is to never go shopping.
@Lee.Willcox
@Lee.Willcox 2 жыл бұрын
@@SkillBuilder 😂Brilliant ! I am not kidding, the number of times other women say to my wife while we are shopping "Why don't you make him stay at home?". I'm always bloody moaning 😩
@geo8rge
@geo8rge 2 жыл бұрын
Is weight an issue due to the floor failing? I could see a 120 liter unit weighing at 250 kilos 300 lb, might even be considered a live load as it fills and empties over and over. Is that the 450 liter?
@SalamanderPumps
@SalamanderPumps 2 жыл бұрын
Morning. Thanks for your comment. The AccuBoost 450L will weigh 281kg when filled, and the 120L weighs 132kg when filled. Depending where the unit is stored, some reinforcement work may need to be done.
@SootheSound
@SootheSound 2 жыл бұрын
Amazing, sounds like it would fix our flow issues. Wish I knew about these years ago.
@SalamanderPumps
@SalamanderPumps 2 жыл бұрын
Hi, you can browse our full accumulator range at www.salamanderpumps.co.uk/range/accuboost/28
@t.k.morris
@t.k.morris 2 жыл бұрын
Will the bolt adjuster in a pressure regulator valve come out if you turn it too many times to reduce water pressure? I need to turn my pressure down but I am not sure if the old regulator is working or just has been turned up too high previously.
@SkillBuilder
@SkillBuilder 2 жыл бұрын
It shoudn't come out.
@t.k.morris
@t.k.morris 2 жыл бұрын
@@SkillBuilder Thank you. Counter Clock Wise is correct for lowering the water pressure correct?
@Simon-qn5wm
@Simon-qn5wm Жыл бұрын
Interesting concept & a good idea, but after having a burst pipe last year, large Water tanks & flexible pipes would make me anxious every time I went out.
@PBSONE555
@PBSONE555 2 жыл бұрын
How would you improve pressure in a 4th floor one bed flat, electric shower won't run hot before 6.30am, then after 6.30 it kicks in, driving me mad any suggestions?? Thanks 👍
@SalamanderPumps
@SalamanderPumps 2 жыл бұрын
Hi Phillip, if it is only the one electric shower that requires boosting, you could look into one of our single outlet TapBoost pump.
@terrywilkins5266
@terrywilkins5266 2 жыл бұрын
Hi Roger, we live in a bungalow. Would we dispose of the tank in the loft if we fitted this system ?
@SkillBuilder
@SkillBuilder 2 жыл бұрын
yes but you will need an unvented cylinder unless you have a combination boiler. If your mains pressure is good you might not even need the Acuboost.
@MrEspadrilles
@MrEspadrilles 2 жыл бұрын
Don't know why these aren't more popular. Have just converted my system to unvented. Pressure is ....better but not great if two showers on at the same time. So will be installing one of these in the garage, along with some other pipework changes here and there... much easier than laying a new mains pipe!
@SalamanderPumps
@SalamanderPumps 2 жыл бұрын
Thanks for your comment! If you need any help or advice with your installation we'd be happy to help, www.salamanderpumps.co.uk
@leonarddetommaso1915
@leonarddetommaso1915 2 жыл бұрын
I live in florida is there any company that sell this in the united States ?
Increase Water Pressure to a Shower or the Whole House | Right Pump
24:12
HOW TO FIX LOW WATER PRESSURE in your HOME....(The SOLUTION..)
17:29
M J Tiff Plumbing
Рет қаралды 16 М.
БАБУШКА ШАРИТ #shorts
0:16
Паша Осадчий
Рет қаралды 4,1 МЛН
ВЛОГ ДИАНА В ТУРЦИИ
1:31:22
Lady Diana VLOG
Рет қаралды 1,2 МЛН
Andro, ELMAN, TONI, MONA - Зари (Official Music Video)
2:50
RAAVA MUSIC
Рет қаралды 2 МЛН
Their Boat Engine Fell Off
0:13
Newsflare
Рет қаралды 15 МЛН
Kitchen Faucet Leaks at the base. Easy Fix!
7:26
Rosco Reviews
Рет қаралды 2,6 МЛН
Why Your Boiler is Losing Pressure and How to Fix It
12:25
Proper DIY
Рет қаралды 284 М.
What's Causing Your LOW WATER PRESSURE?
21:51
Skill Builder
Рет қаралды 19 М.
Plumbers Hate Me For Showing You This!
23:28
Fix This Build That
Рет қаралды 637 М.
How To Drill A Shallow Well And Never Be Without Water
19:50
HAXMAN
Рет қаралды 6 МЛН
92% of Homeowners Use Teflon Pipe Tape Wrong - Here's Why it Leaks
5:33
Silver Cymbal
Рет қаралды 4,3 МЛН
Why Has Your Wall Cracked? and What Can You Do?
11:53
Skill Builder
Рет қаралды 1 МЛН
HOW TO FIX A LOW WATER PRESSURE & FLOW PROBLEM
18:13
M J Tiff Plumbing
Рет қаралды 216 М.
БАБУШКА ШАРИТ #shorts
0:16
Паша Осадчий
Рет қаралды 4,1 МЛН