Design and Analysis of Underground Water Tank(RCC) using ETABS (Part 3)

  Рет қаралды 18,028

Engineering Edu

Engineering Edu

Күн бұрын

Пікірлер: 22
@reshudavane1741
@reshudavane1741 3 жыл бұрын
Sir it was helpful,but it wud be great if you show how to calculate reinforcement required for the walls
@mahiulhossainbappy7929
@mahiulhossainbappy7929 4 жыл бұрын
i have some queries . hope give me best solution , 1) Why dont you used dead load and live load on slab ?? if you used maybe result will be changed as you shown . 2) why dont you run design command ? 3) make a video for Base and slab of this tank design and detailing also .
@engineeringedu5437
@engineeringedu5437 3 жыл бұрын
Have I not? sorry if I missed that part, but the load from there is so minimal as compared to surcharge load. If I am not mistaken, you are referring to cover slab. In any case,, you should apply the correct loads depends on your case. I did run the design command, do you mean that I didn't show what load combinations I used?... Regarding the design of base slab,, I would normally export to SAFE CSI and run the design there using Strip or Finite ELEMENT TOOLS at least to incorporate the accurate behavior of soil, check the Soil Pressure and settlement as well.. Than you for your queries.
@starttobestar5535
@starttobestar5535 Жыл бұрын
thank you very much , how can we know the thickness of the wall and the reinforcment needed for wall and slab please?
@mohab96
@mohab96 10 ай бұрын
Great video, but what is meshing for?? what does it mean when you mesh?
@tayyabaanjum9552
@tayyabaanjum9552 4 жыл бұрын
Will scale factor is different for when tank is in empty condition ?
@sonjuiktahuidrom4771
@sonjuiktahuidrom4771 2 жыл бұрын
How to get the moment manually for the horizontal load that we applied non uniformly in etabs?
@myoaung525
@myoaung525 4 жыл бұрын
Just assigning fixed supports at wall corner points is not acceptable. But after meshing in analysis process, all mesh points at base level are automatically assigned as fixed by Etabs. So the model is accidentally acceptable. Base slab should be modeled in etabs model and define area spring and assigned at the base of base slab. All the joints at the base should be assigned as restrained in x and y direction and free in z direction. Movement in z direction will be controlled by effect of area spring assigned at the base of base slab. Base slab should be stiffer than walls. Regards
@engineeringedu5437
@engineeringedu5437 3 жыл бұрын
This is to show how to apply lateral loads using non uniform shell loads in Etabs. I would rather export it to safe and design accordingly given modulus of subgrade . Lastly, did you notice that I assumed the water level is just exactly at the base to neglect uplift pressure? By that alone, you should know that I really didn't incorporate the design of basement.
@engineeringedu5437
@engineeringedu5437 3 жыл бұрын
By the way, I knew that you are knowledgeable how FEA works. YOu should know that when you discretize shell elements or even a beam or rods, degrees of freedom at those nodes are automatically set as clamped support and that explains why Etabs assume fixed support at those mesh points at the base and it is not by accident. Otherwise, if you really want to input fixed support then I suggest you divide each elements and apply necessary support conditions which I think is useless since you are using FEM Software. I appreciate your insightful observations.
@nguyenvukhanh4579
@nguyenvukhanh4579 2 жыл бұрын
@@engineeringedu5437 Then you should clarify it in your video. This could lead to misunderstanding of many young engineers who follow your instructions.
@engineeringedu5437
@engineeringedu5437 2 жыл бұрын
@@nguyenvukhanh4579 read my comments up. This is Etabs and it's a 3d model not a frame or 2D like analysis. I won't spoon fed someone who needs informations.
@surinderghurdora8537
@surinderghurdora8537 2 жыл бұрын
great sir thnq🙏
@karam429
@karam429 4 жыл бұрын
Gr8 sir👌👌👌👌
@vinayrm9205
@vinayrm9205 3 ай бұрын
how to take reinforcement details
@alfredonmoratallajr6657
@alfredonmoratallajr6657 4 жыл бұрын
Nice sir
@vpconsultants3660
@vpconsultants3660 4 жыл бұрын
Gr8 video ,thanks for this Sir pls share spread sheet of crack width too
@engineeringedu5437
@engineeringedu5437 3 жыл бұрын
give me your email address..
@srinurao3327
@srinurao3327 10 ай бұрын
In case 2..C = -27.6/3.6 ...the C value negative 7.67 please confirm
@nasserabdouramane2534
@nasserabdouramane2534 5 ай бұрын
what about the design aspect
@donatosahon2096
@donatosahon2096 4 жыл бұрын
sir pls help with your contact I want to share something with you email will be fine
@engineeringedu5437
@engineeringedu5437 4 жыл бұрын
nacion18.angelito@gmail.com
structural analysis of underground water tank (Part 2)
12:30
Engineering Edu
Рет қаралды 15 М.
The actual reason for using stirrups explained
9:01
The Engineering Hub
Рет қаралды 805 М.
Правильный подход к детям
00:18
Beatrise
Рет қаралды 11 МЛН
Мен атып көрмегенмін ! | Qalam | 5 серия
25:41
Как устроен рельефно-шлифовальный станок Анкорд?
2:12
АНКОРД-Станки мебельного производства
Рет қаралды 12
Design of underground water tank (RCC) using ETABS (part 1)
9:52
Engineering Edu
Рет қаралды 24 М.
How To Analysis and Design Water Tank In ETABS & SAFE 2024
28:16
Universal channel 12
Рет қаралды 536
How To Analysis and Design Water Tank In ETABS & SAFE 2023
28:16
Mr EngineerO
Рет қаралды 13 М.
Inside German Best Factory Building the Mighty Porsche 918
17:20
Hexagons Are NotSoGreatAgons
14:36
Con Hathy
Рет қаралды 472 М.
The Logistics Behind a Trump Purchase of Greenland | WSJ
6:08
The Wall Street Journal
Рет қаралды 1,4 МЛН
Design of an underground water tank with sub-soil water in STTADPro
35:03