DID YOu consider the weight of the walls on the when designing the slab in SAFE?
@MrEngineerOАй бұрын
Thank you for watching structural walls weight are considered in etabs
@vasubhadania9 ай бұрын
Can you please make a video on design of staircase.... Modeling is possible I want to know if design of staircase is possible......
@Johnny_Nelson5 ай бұрын
Can it be defined "joint patterns" in ETABS?, for instance dynamic water load
@MrEngineerO5 ай бұрын
joint patterns exist only in sap2000
@syedarsalanali850611 ай бұрын
Instead of music.. You can explain the working..
@mohab968 ай бұрын
Why did you not add rebar ?
@Amla094 ай бұрын
Can't you make the foundation in etabs also?
@MrEngineerO4 ай бұрын
Yes it can be done Please watch my other tutorials about structure with foundation design with this link kzbin.info/www/bejne/ZomXi56mp8-apNU
@M.Lozano3 ай бұрын
6:07 POR QUE MODIFICA CON ESOS FACTORES?
@carlosmolinatorres99672 ай бұрын
Eso dice la norma el ACI son factores de reducción de rigidez. Hay 0.70 para muros no agrietados y 0.35 para muros agrietados
@abd-allahessam759811 ай бұрын
3 x 4.7 x 2 = 28.2 not 12.40
@MrEngineerO11 ай бұрын
Thank you for your attention
@ahmedkamal77387 ай бұрын
Brother it is wrong to design water tank wall by etabs because pier force do not consider horizental moments
@engamirsamyfaragalla47267 ай бұрын
Fr=1.9 *lampa*sqrt Fc AS PER CODE NAME ?? ACI CODE Fr=0.62 LAMPA SQRT FC
@MrEngineerO7 ай бұрын
Dear engineer, thank you for your attention. fr in ACI is based on PSI and can be converted to kgf/cm2 as follows: fr=7.5√f'c in PSI=7.5(0.070307*(√(f'c/0.070307)))=1.9√f'c in kgf/cm2