Sir, how to select the span ratio in max deflection .please explain
@hitnailhalfway24855 жыл бұрын
d=h-2tf is done in books and everywhere Izz is used not Ixx. please clarify sir.
@civilconst5 жыл бұрын
elijah nehader Just follow these steps
@senthi.v29424 жыл бұрын
Its very useful. Can u do the same for AISC Code
@abidibadatali53673 жыл бұрын
Bro u should take load in mm, but u have taken in m at check for deflection
@AmritpalSingh-iv9kg6 жыл бұрын
Very nice sir...tension member by weld v kradijiyee
@civilconst6 жыл бұрын
Thank you. i will make it and upload soon
@shekharsharma54465 жыл бұрын
Sir Question Low Shear ka hai ya High Shear ka Pta Kaise chlega??
@rahulmalpekar14 жыл бұрын
In Deflection Check, putting the value of 'w' it was in kN/m but all other quantities were in N & mm. why so???
@civilconst4 жыл бұрын
Doesn’t matter. if you try to convert them, both will have same value
@roshanpalikhe63795 жыл бұрын
W in deflection must be unfactored total load ???including dead load and self wt???
@roshanpalikhe63795 жыл бұрын
In duggal book it include total load not only live load.Please clarify
@civilconst5 жыл бұрын
live load only , As other loads are constant during designing of steel
@civilconst5 жыл бұрын
It is specified in code
@civilconst5 жыл бұрын
is 800 pg 31 table 6, while selecting deflection limit s/300 , live load is considered
@civilconst5 жыл бұрын
I hope it helped
@urtifili353910 ай бұрын
Please upload more sir
@soundaryahiremani46844 жыл бұрын
Sir, how to find the value of Zp in code book tell me sir plzz
@roshanpalikhe63795 жыл бұрын
In web bucking d is the depth of web.why did you take whole depth???
@civilconst5 жыл бұрын
roshan palikhe See if i put d as web depth the value of d/tw will be small than 64£ for sure. If d is taken greater then condition for web buckling might occur and check for web buckling may arise.
@roshanpalikhe63795 жыл бұрын
@@civilconst but ID code tells us to take depth of web.Also Duggal follows the is code .
@civilconst5 жыл бұрын
Thats correct. But its upto you. in designing we will always take critical values. Web depth is obviously smaller than the total depth, so it will be less critical provided to that the condition due to total depth . I took d as total depth Just for more safety factor. I guess you got my words bro. However buckling occurs within the web depth
@universeisherestudytime8701 Жыл бұрын
mic toh dhng ka lelete sir
@civilconst Жыл бұрын
Yahaa Parle-G khana pad raha hai kali chai mai dubokar acchi mic kahaa se laaye sir