THANKS FOR MAKING A LECTURE. ITS FULL OF KNOWLEDGE. ITS VERY HELPFUL.
@EngineeringLearningPlatform5 жыл бұрын
See description for next parts
@theprobattleknight41856 жыл бұрын
Very informative etabs tutorials for building design
@showmitrabarua25555 жыл бұрын
Thank you very much for your helpful tutorial . But commanding so quick.
@EngineeringLearningPlatform5 жыл бұрын
See description for next part of this video
@Engrwaleed5553 жыл бұрын
Hi, Did you applied wall load during this tutorial?
@williamsentemtz96524 жыл бұрын
Thank you very much sir...You helped a lot for my final year engineering project 😊 There is detailing option is missing on etabs 2017, Can we trust the CSI detailer as it is new?
@EngineeringLearningPlatform4 жыл бұрын
Go for 2016
@Engrwaleed5553 жыл бұрын
4:16, Shear wall properties modifier is 0.5? And why only in one direction?
@ramonsaclolo25143 жыл бұрын
Any reply to this?
@hariasssss5 жыл бұрын
please explain about the auto sequence loading concept in one video.how to do that auto sequence analysis?
@mohidirfan69142 жыл бұрын
Do we not change the strength reduction factors for UBC 97 while using ACI-08 ? Wont they be different ?
@EngineeringLearningPlatform2 жыл бұрын
UBC 97 is highly conservative
@gaganpatidar99074 жыл бұрын
Sir, if we change the number of longitudinal reinforcement in 2 and 3 directions will affects the reinforcement area. These options are below the clear cover option in column define properties.
@EngineeringLearningPlatform4 жыл бұрын
For slab design?
@gaganpatidar99074 жыл бұрын
@@EngineeringLearningPlatform no in the column design
@EngineeringLearningPlatform4 жыл бұрын
@@gaganpatidar9907 Let it remain default
@gaganpatidar99074 жыл бұрын
@@EngineeringLearningPlatform I did research in this area and I found something that. We have to change them because bars of the size there define the nominal cover . Like we assume in our manual calculation of axial loading and biaxial bending of column. If that remain to 20 mm bars then in small size column it give unnecessary large reinforcement area. Also it affect the criteria of selecting equal bars on two sides or four sides. But I can't understand that why it affect result when we increase the number of bars. You check this by yourself . Make 2 same structure but change only the number of longitudinal bars in 2 and 3 direction in column definition. You will notice diferrence in reinforcement area. I want to talk more in this topic . I hope u reply.
@EngineeringLearningPlatform4 жыл бұрын
@@gaganpatidar9907 I know . You should study the moment interaction curves of columns . And suggested is to keep uniform rebar distribution .
@firassmohamad16956 жыл бұрын
Nice, but it seems that you did not assign the wind coefficients Cp to get the wind load, did you?
@EngineeringLearningPlatform6 жыл бұрын
Once selected UBC 97 and specified top and bottom storey etabs will automatically take Cp values into consideration . But u can always overwrite them .
@Anujdt5 жыл бұрын
Sir, why stiffness modifier for Beam in torsion is 0.001? Could you explain?
@EngineeringLearningPlatform5 жыл бұрын
Because its upto us whether we want beam to be designed for torsion or not . Since i took 0.001 so it makes beam torsionally flexible i.e the slab will absorb all torsion and beam will not have additional steel for torsion. Its choice of designer
@Anujdt5 жыл бұрын
@@EngineeringLearningPlatform Sir, we usually see the beam fail in torsion while using modifier 1.0 or 0.35, is it right to say the slab will take all the torsional moment generated? I have been having problems on the torsion issue in beams which leads to increase in size and issuance of higher grade of concrete to it
@EngineeringLearningPlatform5 жыл бұрын
Yes the slab will be designed stiffer and you'll see it would stop failing the beam then .
@Anujdt5 жыл бұрын
@@EngineeringLearningPlatform does it mean we input 0.25 for slab modifier or 1.0? Since slab will be stiffer and ETABs will design the slab accordingly, and we can also provide torsional reinforcements in slabs
@EngineeringLearningPlatform5 жыл бұрын
Actually in slab there is no comcept of torsion, it is a moment which is transferred to the beam from slab and then it becomes torsion for beam, and yes we reduce slab's stiffness to 0.25 for sake of code to incorporate cracked moment of inertia
@Engrwaleed5553 жыл бұрын
Torsional constant should be 0.01 or 0.001? Please cross check.
@EngineeringLearningPlatform3 жыл бұрын
Doesn't matter, 0.01 is already making it 10% of it's capacity, 0.001 will be using only 1% . Both can be used . Even 0.1 can be used . While ACI recommendation for compatibility torsion is 0.001 conservatively . It's now your choice how much conservative you want to be . You can try using both and see no or minor difference
@Engrwaleed5553 жыл бұрын
@@EngineeringLearningPlatform Alright Cool. And why don't use reduce torsion value for column as well? We reduce it for beams only?
@EngineeringLearningPlatform3 жыл бұрын
Beam's compatibility torsion is shared by slab thats is why we reduce that in internal beams, but not in external beams . While columns can't ignore torsion as no other sharing element, and why would a Structural Engineer not want column to be designed for forces coming to it . It doesn't make sense . Further more see ACI chapter 10, it mentions torsion modifiers are only applicable to beams .
@mreng46614 жыл бұрын
Sir when i run analysis, analysis will complete but model didn't get locked. Also etabs not showing deformed shape. What is reason please help.
@EngineeringLearningPlatform4 жыл бұрын
Corrupt model or check modal analysis and see if it run
@mreng46614 жыл бұрын
@@EngineeringLearningPlatform i made a new model as you did.