Determination of HMF (HydroxyMethylFurfuraldehyde) in Honey Using UV Spectrophotometer_Complete Test

  Рет қаралды 11,094

MicroChem's Experiments

MicroChem's Experiments

Күн бұрын

Пікірлер: 52
@Wardi_lovers
@Wardi_lovers 3 жыл бұрын
One chanal Which I really like. That's it. Very useful your all videos are very useful and important. Thanks lot ❤️
@MicroChemsExperiments
@MicroChemsExperiments 3 жыл бұрын
Thank you so much. We are so glade
@VyNguyen-cv5fz
@VyNguyen-cv5fz Жыл бұрын
I have a question, why do we have to reject the first 10 mL of filtrate? Thank you!
@manobendramohanta1237
@manobendramohanta1237 Жыл бұрын
Thanks a lot. Would you please share the reference which you followed?
@bappyislam1452
@bappyislam1452 3 жыл бұрын
why carrez solution is necessary in this procedure?
@MicroChemsExperiments
@MicroChemsExperiments 3 жыл бұрын
To enhance the HMF content to be determined
@tyasayuwulandari7854
@tyasayuwulandari7854 3 жыл бұрын
I want to ask, why use two wavelengths on this test?
@MicroChemsExperiments
@MicroChemsExperiments 3 жыл бұрын
Because Kries method said so
@tyasayuwulandari7854
@tyasayuwulandari7854 3 жыл бұрын
@@MicroChemsExperiments the kries' method of testing oil delicacy?
@MicroChemsExperiments
@MicroChemsExperiments 3 жыл бұрын
@@tyasayuwulandari7854 Sorry. I made a mistake. This video is made by following AOAC 980.23. So, AOAC 980.23 said to use two wavelength
@tyasayuwulandari7854
@tyasayuwulandari7854 3 жыл бұрын
How does the principle of hydroxsymmetilfurfural analysis use spectrophotometri?
@MicroChemsExperiments
@MicroChemsExperiments 3 жыл бұрын
@@tyasayuwulandari7854 Please read the AOAC method for more.
@raveenank2402
@raveenank2402 Жыл бұрын
How the absorbance can be measured in two wavelength? Keeping reference in blank and test sample in next port?
@MicroChemsExperiments
@MicroChemsExperiments Жыл бұрын
No. Only one port is used. Keep sample in one holder setting 2 wavelengths in the operating software. It will measure 2 absorbance of sample one after another
@raveenank2402
@raveenank2402 Жыл бұрын
@@MicroChemsExperiments thank you
@bloomingbuds3031
@bloomingbuds3031 Жыл бұрын
Can you make a video on HMF of honey by winker method????
@Jestrick
@Jestrick 3 жыл бұрын
Great video! mind telling, in HMF formula what's 149.7 x 5 ?
@MicroChemsExperiments
@MicroChemsExperiments 3 жыл бұрын
Calculation factor
@Jestrick
@Jestrick 3 жыл бұрын
@@MicroChemsExperiments why are we even multiplying that? can you explain a bit, what quantity is that, mass, volume of numeric?
@rameshjoshi4101
@rameshjoshi4101 2 ай бұрын
Great💯
@qcecobeeshop7543
@qcecobeeshop7543 2 жыл бұрын
Hi. I want to ask, can we use single beam UV-VIS spectrophotometer for this ? Is the reference necessary? Thank you in advance!
@MicroChemsExperiments
@MicroChemsExperiments 2 жыл бұрын
You can
@paullloydsonalvarez1973
@paullloydsonalvarez1973 2 жыл бұрын
@@MicroChemsExperiments If single beam UV-VIS will be used, are we going to read the the absorbance of the blank first then sample solution at 284 nm, then repeat at 336 nm (blank then sample)?
@raoism
@raoism 3 жыл бұрын
Blank solution of filtered sample ( Honey sample 5ml + sodium disulphite ml ) Kept in Blank slot of spectrophotometer... Filterd sample ( Honey sample 5ml + distilled water ml ) kept in sample slot of spectrophotometer is it right ? ?
@MicroChemsExperiments
@MicroChemsExperiments 3 жыл бұрын
Do test according to this video.
@palas987654321
@palas987654321 3 жыл бұрын
Hi, Any Video available for Honey diastase activity testing?? Thanks
@MicroChemsExperiments
@MicroChemsExperiments 2 жыл бұрын
Yes, soon
@palas987654321
@palas987654321 2 жыл бұрын
@@MicroChemsExperiments Any honey diastase activity video available now??
@margotguedon552
@margotguedon552 2 жыл бұрын
Why absorbance is measured for these wavelenghts 284 and 336nm? (I can't find AOAC 980.23 on internet)
@MicroChemsExperiments
@MicroChemsExperiments 2 жыл бұрын
Plz check the latest version of AOAC properly
@manelbouraghda577
@manelbouraghda577 2 жыл бұрын
Can we replace deionized water with distilled water?
@MicroChemsExperiments
@MicroChemsExperiments 2 жыл бұрын
Using DI WATER is better. But you can also use DW
@kartickbera3691
@kartickbera3691 3 жыл бұрын
In AOAC 980.23 Official method (1983) there mentioned sodium bisulfite (sodium hydrogen sulfite). But in your video there mentioned sodium disulfite (sodium metabisulfite). What is the difference between two procedure? Kindly can you tell me where it is mentioned sodium disulfite?
@MicroChemsExperiments
@MicroChemsExperiments 3 жыл бұрын
Sodium Disulfite and bisulfite are same in chemical composition. So, do not panic with it.
@palas987654321
@palas987654321 3 жыл бұрын
Is it required to purchase carrez solutions? Or we can prepare by following your shared chemicals. Would you pls share carrez solutions preparation method or reference ?
@MicroChemsExperiments
@MicroChemsExperiments 3 жыл бұрын
You can prepare. Reference: AOAC 980.23
@palas987654321
@palas987654321 3 жыл бұрын
@@MicroChemsExperiments Thanks. Would you pls share the Reference: AOAC 980.23
@MicroChemsExperiments
@MicroChemsExperiments 3 жыл бұрын
@@palas987654321 Sorry. We don't provide any document.
@brigittegrimm7089
@brigittegrimm7089 2 жыл бұрын
Is this only for honey testing or can it be used for testing HMF levels in juice?
@MicroChemsExperiments
@MicroChemsExperiments 2 жыл бұрын
Only for honey sample but you can try for juice
@vatsalvasvelia9658
@vatsalvasvelia9658 Жыл бұрын
Kindly make video on Fiehe’s test for honey
@MicroChemsExperiments
@MicroChemsExperiments Жыл бұрын
Noted
@prathiumanan938
@prathiumanan938 3 жыл бұрын
This suitable for double beam spectrophotometer
@MicroChemsExperiments
@MicroChemsExperiments 3 жыл бұрын
Yes
@shriyanshdixit261
@shriyanshdixit261 2 жыл бұрын
Please explain how absorbance of sample soln is changed from 284 into .284 and 334 into .004
@MicroChemsExperiments
@MicroChemsExperiments 2 жыл бұрын
You have to set two wavelengths during method setup
@azharhemeed5045
@azharhemeed5045 2 жыл бұрын
Excellent
@MicroChemsExperiments
@MicroChemsExperiments 2 жыл бұрын
Thank you
@aswinkumar8016
@aswinkumar8016 3 жыл бұрын
Super
@MicroChemsExperiments
@MicroChemsExperiments 3 жыл бұрын
Thank you
@inekenabilah8486
@inekenabilah8486 3 жыл бұрын
11:48
@MicroChemsExperiments
@MicroChemsExperiments 3 жыл бұрын
Any problem here?
Vitamin-A & Vitamin-E Analysis Using HPLC_Part-2 (Instrumental Analysis)
21:15
MicroChem's Experiments
Рет қаралды 12 М.
1% vs 100% #beatbox #tiktok
01:10
BeatboxJCOP
Рет қаралды 67 МЛН
Каха и дочка
00:28
К-Media
Рет қаралды 3,4 МЛН
Правильный подход к детям
00:18
Beatrise
Рет қаралды 11 МЛН
Determination of Crude Fiber Content -A Complete Procedure (AOAC 978.10)
22:07
MicroChem's Experiments
Рет қаралды 124 М.
Determination of Peroxide Value_A Complete Procedure (AOAC 965.33)
8:45
MicroChem's Experiments
Рет қаралды 140 М.
Honey Testing
4:34
Rural Delivery
Рет қаралды 29 М.
How to check the honey is real or not? | GWAI
9:18
Aftab Iqbal
Рет қаралды 3,6 МЛН