Best technical video tutorials 1. Dse 7320 full course video tutorial lnkd.in/dCPHvrk 2. How to read Electrical Drawings Video tutorial lnkd.in/g8v6BEG 3.how to bypass generator AVR lnkd.in/dP6Xn-Kd 4. Three phase genrator excitation system video tutorial lnkd.in/dE8ZDz3 #generator #dieselgenerator #generators #Electricgenerator #electricalengineering #electricalengineers #Engineering #Electrical #techjobs #technicalsupport
@gorobishe-fn1tn Жыл бұрын
Hw can I get Yu what apps number pla
@deeprajshanker23254 ай бұрын
Thank for clear explanation
@alimorad5474Ай бұрын
شكرا لك على الشرح القيم وأسلوبك الراقي
@JoaozitoMorais-q5kАй бұрын
11:01
@fantech728 ай бұрын
Very good explanation! Thanks 😅
@DieselGeneratortraining8 ай бұрын
Glad it was helpful!
@veluvelmurugan58894 ай бұрын
Thank you sir
@KimoSash-b3y4 ай бұрын
Ⓥⓔⓡⓨ ⓖⓞⓞⓓ ⓔⓧⓟⓔⓝⓔⓣⓘⓞⓝ 👍
@mdmodassirkhan22963 ай бұрын
Make in hindi is th best
@DieselGeneratortraining2 ай бұрын
Hindi mai video agai hai channel per
@mansureee9449 Жыл бұрын
Super
@gagaiowbagal49902 жыл бұрын
HOW CAN I KNOW THE OPEN RELAY IS UVR OR MX. WITHOUT OPENING THE BREAKER.
@fantech728 ай бұрын
Can you explain me the function of the shunt Trip in a motorized breaker? With the elec diagram ? please
@angelitocortez4738 Жыл бұрын
Thanks a lot. Please can you send me the wiring diagram for using ats this type of ACB.with 3 timer and relays with selector switch auto off manual
@nickagravante69172 жыл бұрын
Thanks sir
@jaimetemplo37262 жыл бұрын
brod can you give me a diagram for this circuit breaker,
@aadedeelectric2 жыл бұрын
Nice info..great job bro thank you
@DieselGeneratortraining2 жыл бұрын
Always welcome
@jabbarali8312 жыл бұрын
Really a great effort I have a question auxiliary SDE contact when change its position.suppose breaker is off point 81 and 82 are closed .but when breaker turn on then SDe also change its contacts my means 81 and 84 becomes close or only it change contacts position when it get trip. Please clear this point
@MrTHOTTADA10 ай бұрын
It closes only when there is trip alarm
@kvikas88kvikasdd Жыл бұрын
Sir,I have schneider air circuit breaker EDO type. I have one question air circuit breaker its close position ,once power coming its should not be operate automatically .. In this situation what have to do ? Because ,our side local supply not well running 10 minutes coming after shut down after again 2 minutes coming ... So I want automatically on controll manually..
@songanojoshua165111 ай бұрын
Same question but my acb is lagrand. Breaker is not connected to supply to the mains because when power off the generator runs and few seconds it stop because the acb is not connected to bus line how to fix it sir and how to know the problem. I have 3 coils UVT, CC, SHUNT.
@surendrakverma555 Жыл бұрын
Good 👍
@DieselGeneratortraining Жыл бұрын
Thank you! Cheers!
@amolaegade542810 ай бұрын
remote operation k through breaker trip aur reset kaise hota hai iska working explanation video banayie sir
@songanojoshua165111 ай бұрын
Same question but my acb is lagrand. Breaker is not connected to supply to the mains because when power off the generator runs and few seconds it stop because the acb is not connected to bus line how to fix it sir and how to know the problem. I have 3 coils UVT, CC, SHUNT.
@DieselGeneratortraining11 ай бұрын
Ur doing Generator synch with Grid supply
@songanojoshua165111 ай бұрын
@@DieselGeneratortraining yes brother but there has no connection if there power interruptions the breaker is not function to close
@AminulIslam-hq7ot2 жыл бұрын
Thank you so much
@DieselGeneratortraining2 жыл бұрын
You're most welcome
@mohameedgamal5421 Жыл бұрын
In NW breaker have 3 positions. A1, A2 , A3
@DieselGeneratortraining Жыл бұрын
I will see
@mohameedgamal5421 Жыл бұрын
Al samalo aleekm Please I need to contact you
@johnSakala-ke9lz Жыл бұрын
what would cause the breaker to closed then immediately open again