Digikeijs DR4088 Mimic panel analog switch to digital address.

  Рет қаралды 3,238

DCCtrainautomation

DCCtrainautomation

Күн бұрын

Пікірлер: 35
@EssexThameside
@EssexThameside 3 жыл бұрын
As I have just clarified with James, the thing I like about this simple solution (as opposed to the other ways I was looking at) is that it can be added retrospectively. First get your head around getting things working on (in my case) DR5000 and if you choose iTrain. When it is all running you can decide were you would like to add your switch control and then build the mimic and connect the S88 to the DR5000. Brilliant Brian Essex Thameside in N
@lgrfbs
@lgrfbs 3 жыл бұрын
Thanks for an informative video. The sound knows a little sharply in some places, but heard you clearly. Can we get a video about DRscripting?
@DCCtrainautomation
@DCCtrainautomation 3 жыл бұрын
I don’t use the DR script sorry.
@davidjohnashby
@davidjohnashby 2 жыл бұрын
Hi slightly off topic I have a dr5000 control with the dr4088 my question is does the live from the 5000 go to the com on the 4088 and the 16 sensor wires that go to the blocks (the rail that is isolated ) is it a red Cable Live?? and the rail that is not broken into sections having a Black wire which goes back via the negative bus to the dr 5000
@DCCtrainautomation
@DCCtrainautomation 2 жыл бұрын
Yes you do.
@davidjohnashby
@davidjohnashby 2 жыл бұрын
Thankyou
@rmack255
@rmack255 3 жыл бұрын
Awesome! Why has no one else explained about that S88 assignment ability? After you told me I found it in section 7.1 of the DR5000 manual, but since they left it in German or Dutch, it wasn’t real obvious what it did :/ Question: with the 4088Opto, can I utilise a voltage input as the switched input? Ie, 12v dc on one input for green, other input for red? I think this is possible, but only with opto, not GND.
@DCCtrainautomation
@DCCtrainautomation 3 жыл бұрын
If you use the OPTO you don’t need to add power that’s way I did it this way uses the track current.
@whetstonebridge4801
@whetstonebridge4801 3 жыл бұрын
Very interesting. One of the downsides of iTrain has been the lack of a 'real' mimic panel. How many turnouts for each DR4088?
@DCCtrainautomation
@DCCtrainautomation 3 жыл бұрын
This is only one solution to have this in iTrain or Train Control there are many others for other systems and they have been around for a very long time.
@whetstonebridge4801
@whetstonebridge4801 3 жыл бұрын
@@DCCtrainautomation Thanks highlighting this function. Seems obvious now that a feedback could tell iTrain to carry out a command. Should have thought it through before.
@HumancityJunction
@HumancityJunction Жыл бұрын
One of these days I need to figure out the difference between the GND and the OPTO versions.
@DCCtrainautomation
@DCCtrainautomation Жыл бұрын
The GND is volt free detector and the OPTO is Low voltage.
@HumancityJunction
@HumancityJunction Жыл бұрын
@@DCCtrainautomation If I want to detect the SPDT output of a Cobalt Digital iP, which one should I use? I own several of the GND version, but don’t know if that’s correct.
@DCCtrainautomation
@DCCtrainautomation Жыл бұрын
@@HumancityJunction www.dcctrainautomation.co.uk/blog/point-detection-position-for-computer-control.html
@HumancityJunction
@HumancityJunction Жыл бұрын
@@DCCtrainautomation I saw that article and drawing which is why I got the GND units. Looks like my plan should work :)
@ravenscrossmodelrailway3281
@ravenscrossmodelrailway3281 3 жыл бұрын
Hi James, great video, I have one 4088 on LN and one linked via S88 from the one on LN. Can I still do this or do they have to be direct to the S88 on dr5000 ?
@DCCtrainautomation
@DCCtrainautomation 3 жыл бұрын
Hello thanks for the question. You can not do it through the LN version no. You would need to disconnect it and put it to the S88 port on the DR5000
@ravenscrossmodelrailway3281
@ravenscrossmodelrailway3281 3 жыл бұрын
@@DCCtrainautomation thanks James. As my s88 are free on the dr5000 I may invest in one of the opto versions just for this job of control mimics. I take it you still have to give it the 1st address and the others are sequential? Nice if they could be independently given the address. My layout is a learning layout so a rejig of the address wouldn't be to difficult. Keep up the good work😁
@DCCtrainautomation
@DCCtrainautomation 3 жыл бұрын
@@ravenscrossmodelrailway3281 hello you can set what address the S88 starts at it does not have to be on 1-16 you can start any were you like.
@ravenscrossmodelrailway3281
@ravenscrossmodelrailway3281 3 жыл бұрын
Also dose it have to be xx versions and how can I tell if mine are. Very interested in doing this.
@DCCtrainautomation
@DCCtrainautomation 3 жыл бұрын
Hello It has to be the S88 version of the 4088 and then either the GND version or the OPTO one. It is in the instructions.
@MrMatthewstrike
@MrMatthewstrike 3 жыл бұрын
@@DCCtrainautomation This video seems to suggest it can be done on the LN version. kzbin.info/www/bejne/qZCsd2WmgJieors Although I can’t see how as the manual only shows the GND and opto, and as far as I can tell the LN doesn’t have the modules option to tell it what kind of switch / button is connected. Any ideas?
@DCCtrainautomation
@DCCtrainautomation 3 жыл бұрын
@@MrMatthewstrike no it can not be done on loconet I said it can not be done on anything but S88 units
@chrislockerby1411
@chrislockerby1411 3 жыл бұрын
Very Interesting as you know i'm just in the process of converting my Layout to run with Digikeijs and iTrains how do i solve the problem of a train running into a turnout set against it and creating a short as at the moment i have to use the hand of God to move the loco back off the point and reset the DR5000.I then move the point or can i still use my old mimic panel to set the point or how do i set Itrains to stop the loco or move point automatically to favour the loco Keep up the good work
@DCCtrainautomation
@DCCtrainautomation 3 жыл бұрын
Hello Chris please send me the iTrain File you have and i can see were you are going wrong.
@chrislockerby1411
@chrislockerby1411 3 жыл бұрын
@@DCCtrainautomation Thanks for the prompt reply I have only got the 2 month trial licence at the moment but hope to buy standard or pro
@DCCtrainautomation
@DCCtrainautomation 3 жыл бұрын
@@chrislockerby1411 you can send be the Tcdz file though can see were the problem is. And get you moving forward.
@chrislockerby1411
@chrislockerby1411 3 жыл бұрын
@@DCCtrainautomation will get it when I’m up in my loft tomorrow Many Thanks
@yarisman2
@yarisman2 3 жыл бұрын
Hi, can you use a DR4018 to operate solenoid points?
@DCCtrainautomation
@DCCtrainautomation 3 жыл бұрын
Hello Clive the answer is no. The dr4018 spec it not designed for peco or seep solenoids.
@yarisman2
@yarisman2 3 жыл бұрын
@@DCCtrainautomation thanks for your reply, appreciated.
@whetstonebridge4801
@whetstonebridge4801 3 жыл бұрын
@@yarisman2 Been there. Recommend that you don't even try it! I damaged one of my DR4018s by persisting with solenoids. MTB MP1s + DR4018s have been great for me.
@yarisman2
@yarisman2 3 жыл бұрын
@@whetstonebridge4801 Thanks for the info.
@chrislockerby1411
@chrislockerby1411 3 жыл бұрын
@@whetstonebridge4801 I've gone over to MTB 1 motors wouldn't go back to solnoids
DR4018 switching UK 3 aspect signal
6:45
DCCtrainautomation
Рет қаралды 2,2 М.
Когда отец одевает ребёнка @JaySharon
00:16
История одного вокалиста
Рет қаралды 16 МЛН
버블티로 부자 구별하는법4
00:11
진영민yeongmin
Рет қаралды 25 МЛН
啊?就这么水灵灵的穿上了?
00:18
一航1
Рет қаралды 86 МЛН
Flint Hills 23 - Fixing a Digikeijs DR 4018
11:28
Geoff Hammond - Flint Hills Model Railway
Рет қаралды 1,1 М.
Creating accessory's
8:55
DCCtrainautomation
Рет қаралды 1,3 М.
YaMoRC YD6016LN-CS Track Detection No4
8:01
DCCtrainautomation
Рет қаралды 9 М.
Block Detection with LoDi. No 8.
20:05
DCCtrainautomation
Рет қаралды 2,2 М.
NAS vs. Home Server - What's the difference?
7:31
Wolfgang's Channel
Рет қаралды 389 М.
#1099 How I learned electronics
19:55
IMSAI Guy
Рет қаралды 1,3 МЛН
Let's build a voltage multiplier!
16:32
Ben Eater
Рет қаралды 2,1 МЛН
Model Railroad - How To - Switch machine with LED's
9:19
Boulder Creek Railroad
Рет қаралды 144 М.
Когда отец одевает ребёнка @JaySharon
00:16
История одного вокалиста
Рет қаралды 16 МЛН