Directional Overcurrent Protection of a Wind Farm Collector

  Рет қаралды 3,170

ETAP Software

ETAP Software

Күн бұрын

etap.com - Full range reactive power support is available in case of electronically-coupled generation sources such as wind turbine generation (WTG) types 3 and 4. If WTG active power generation is less than its auxiliary power while WTG absorbs inductive reactive power from the system, the current angle measured by the directional element resembles a current angle occurring during forward fault as observed by the collector protection relay. This may lead to a false trip and loss of wind power generation.
In this webinar, challenges of directional protection of wind farm collectors will be demonstrated. ETAP StarZ™ - Protection & Coordination module will be utilized to set and analyze directional overcurrent protection of wind power plant collectors. Finally, a few solutions offered by the industry will be presented and evaluated.
#ETAPsoftware
#electricalsoftware
#PowerSystemAnalysis
#PowerSystemAnalysisSoftware
#electricalindustry
#electricalengineering
#energynews
#electricalindustry
#electricalenergy
#ElectricalDesign
#electricalservices
#ElectricalDigitalTwin
#SmartGrids
#ResilientPowerSystems
#AllElectricWorld
#ProtectiveDeviceCoordination
#renewables
#CleanEnergy
#renewableelectricity
#RenewableEnergy
#windfarm
#windpower
#windgen

Пікірлер: 9
@gharbigarbi3285
@gharbigarbi3285 Жыл бұрын
What is better, installing a sheath voltage limiter (SVL) on cable ends or directly connecting them to the grounding system?
@wongsabarchannel1335
@wongsabarchannel1335 Жыл бұрын
In ETAP why there is no Differential Slope setting?
@ETAPsoftware
@ETAPsoftware Жыл бұрын
Thank you for your interest in ETAP Software. ETAP's StarZ Module for transmission and distribution system protection & coordination, offers vendor-specific differential protection with settings provided by vendors including differential slope. The ETAP analysis is based on ideal differential protection. For more information visit etap.com/product/starz-distance-relay-coordination or contact our 24/7 Help Center for assistance.
@wongsabarchannel1335
@wongsabarchannel1335 Жыл бұрын
@@ETAPsoftware Is the any video tutorials for differential star Z?
@ETAPsoftware
@ETAPsoftware Жыл бұрын
@@wongsabarchannel1335 You can try this video "ETAP StarZ™ - A Realistic Approach & New Insight to Protection & Coordination Analysis" kzbin.info/www/bejne/bZ3dkIOhesmspas
@wongsabarchannel1335
@wongsabarchannel1335 Жыл бұрын
Hello ETAP, can i find video tutorial for UPS parameter setting in ETAP? Since i could not find Bypassed Switch Status feature in ETAP.
@ETAPsoftware
@ETAPsoftware Жыл бұрын
Thank you for your interest in ETAP Software. For more information or assistance you can always contact our 24/7 Help Center at helpcenter.etap.com
@windspeedmetersandanemomet6444
@windspeedmetersandanemomet6444 3 жыл бұрын
☑☑ COOL SOFTWARE
@ETAPsoftware
@ETAPsoftware 3 жыл бұрын
Thank you for your interest in ETAP Products and you positive feedback
How 3 Phase Power works: why 3 phases?
14:41
The Engineering Mindset
Рет қаралды 2,2 МЛН
Don’t Choose The Wrong Box 😱
00:41
Topper Guild
Рет қаралды 62 МЛН
When you have a very capricious child 😂😘👍
00:16
Like Asiya
Рет қаралды 18 МЛН
Sigma Kid Mistake #funny #sigma
00:17
CRAZY GREAPA
Рет қаралды 30 МЛН
Lecture 1: Introduction to Power Electronics
43:22
MIT OpenCourseWare
Рет қаралды 1 МЛН
Inside the V3 Nazi Super Gun
19:52
Blue Paw Print
Рет қаралды 3,2 МЛН
The Mechanical Battery Explained - A Flywheel Comeback?
11:19
Undecided with Matt Ferrell
Рет қаралды 2,5 МЛН
How to perform DC Arc Flash Studies for BESS in ETAP 2024​
49:24
ETAP Software
Рет қаралды 1,9 М.