So helpful as always. Specifically the 3D model made it extremely understandable. Thanks indeed
@GauravJ9 ай бұрын
Glad it was helpful!!
@surendrakverma5558 ай бұрын
Very good. Thanks 🙏
@Navi_Habakkuk9 ай бұрын
Great insights. Helpful
@GauravJ9 ай бұрын
Glad it was helpful!!
@mulengakalyafye60009 ай бұрын
please do performance of transmission lines.... current, resistance, capacitance, sending end and receiving end voltages
@AdarshLobo9 ай бұрын
If we are planning to phase out SF6, then what can we replace it with in these DCBs?
@EdEOS9 ай бұрын
This is cool, what about the visual proof of the specific circuit isolation from the rest of the circuit? ( maintenance folks always want to see that) and clearance ground to the disconnect switch?
@GauravJ9 ай бұрын
Unfortunately, With DCB there is no visual proof!
@itsmohsinali9 ай бұрын
Since when were they introduced?
@azmalajuba52349 ай бұрын
I want to buy course but on app demanding refer code which is not available without it how can i signup
@GauravJ9 ай бұрын
@azmalajuba5234 referral code is not required. Sign in on courses.theelectricalguy.in
@chrisnachos227 ай бұрын
Is the lack of visual proof a big negative? How can you be sure it is isolated before earthing? Current transformer to measure the current downstream or something else?
@Ahmedelatawy-p5g4 ай бұрын
Thanks you
@Veerubhaai9 ай бұрын
Disconnector Circuit Breaker, highlighting its durability, easy installation, and reliable safety features.
@jimmygeorge119 ай бұрын
Helpful 😍
@adnantanjir9 ай бұрын
How did you make this 3D video. Thats awesome brother. Make it easy to understand the topic.
@swapnilmajee39629 ай бұрын
Helpful
@GauravJ9 ай бұрын
Thanks for the feedback
@himmlerassing18469 ай бұрын
Awesome
@GauravJ9 ай бұрын
Glad it helped !
@aiasolarsolution36467 ай бұрын
more helpful
@hildemarsandovalguevara33973 ай бұрын
Una desventaja que puedo encontrar, por ejemplo: en una subestación de 220 KV de una central de generación; para poder darle el mantenimiento a su transformador de potencia de salida, necesitaría también poner fuera de servicio la línea de transmisión. Con la configuración antigua puedo abrir el interruptor, abrir el seccionador de barra (lado del transformador) y cerrar el seccionado a tierra del lado del transformador y mantener la línea de transmisión energizada. Con la configuración actual al tener un solo seccionador e tierra no podría aterrar mientras no ponga fuera de servicio a la línea. TRADUCCIÓN: "One disadvantage I can find, for example, in a 220 kV substation of a generation plant, is that in order to perform maintenance on its output power transformer, I would also need to take the transmission line out of service. With the old configuration, I can open the circuit breaker, open the bus disconnect switch (on the transformer side), and close the ground disconnect switch on the transformer side, keeping the transmission line energized. With the current configuration, having only one ground disconnect switch, I wouldn't be able to ground while the line remains in service."
@mukundchabukswar26409 ай бұрын
How these C.B. CAN BE USED FOR EHV LINES IN GREED ? Supply is present from both side. These can be suitable for Transformer breaker, but not for ICT.
@imeprezime12859 ай бұрын
Have you heard of a HV disconnecting "switch" (breaker)? That crazy thing Americans have