What are the key parameters to be monitored to increase maximum feed in column to avoid damage in column
@SPEC7863 жыл бұрын
The operating parameters to be monitored when you are making an attempt to push the load to maximum, that is beyond the rated capacity are pressure drop across the column and column bottom level. Plot the pressure drop in rectification section and stripping section versus vapour rate separately. What is important is the rate of rise in pressure drop against the change in vapour rate. If the rate of change is as before when the column was operating within rated capacity, the column hydraulic is ok. If the rate of increase of pressure drop is steeper, then you have reason to worry. The column is beginning to flood. You have reached the maximum capacity of the column. Continued operation in flooded condition will lead to tray damage. Other parameters to be watched are column bottom level, distillate and bottom product composition during this exercise. A decreasing level in column bottom will indicate the liquid is accumulating on the trays. The column is flooding.
@doinggood35643 жыл бұрын
❤
@lenzfaraday20772 жыл бұрын
Is there a part 2?
@SPEC7862 жыл бұрын
Yes. It is available. Check out in the playlist"distillation"