Пікірлер: 25
@dreednlb
@dreednlb Жыл бұрын
4:00 No mention of SCPT? What does that do?
@theresatrickforthat
@theresatrickforthat Жыл бұрын
SCPT Short Cycle Prevention Timer. Thanks for watching!
@shawnstangeland3011
@shawnstangeland3011 3 ай бұрын
Thanks. Was messing around with the app trying to enter information while not being connected. Thought it might need the serial number etc before connecting on Bluetooth
@theresatrickforthat
@theresatrickforthat 3 ай бұрын
No problem! Thanks for watching!
@rcinfla9017
@rcinfla9017 Жыл бұрын
Current readout is only the run winding current of motor. Does not read start (auxiliary) winding current. This makes it look like Easystart reduces run current, which it does not. Easystart internal relay bypasses Easystart during normal run period. It does reduce startup surge current which is the intended purpose. Start(auxiliary) winding current is about 90 degs out of phase with run winding current, due to run capacitor, so on my 4 ton system with run winding of 10A @240vac and start(auxiliary) winding of 7A@ 300vac, the common current to compressor is sqrt (10^2 + 7^2) = 12.2A from 240vac. Easystart shows the 10A run winding current only, which is about 20% lower than actual total compressor current. This also applies to what is shown of startup surge current. Startup surge is higher than shown. There is more error in the optimum 90 deg phase shift for startup surge due to value of Easystart internal start capacitor that has a wide tolerance and often too large mfd value for given compressor motor capacity. Selecting start capacitor based on BTU's of unit is not accurate due to other factors like size of condenser. Larger condenser unit has smaller rated compressor for the system BTU rating.
@mikec555555
@mikec555555 7 ай бұрын
In other words....what exactly are you saying??? Do you think these soft starts add value or not?
@aholmes6612
@aholmes6612 6 ай бұрын
So in layman's term, you just said what?
@unclelarry623
@unclelarry623 5 ай бұрын
@@aholmes6612 I'm a layman. lol I just installed Easy Start so that I can run my 20 year old 4 Ton AC on a 13,000 watt generator if necessary. Easy start did reduce my inrush (start up) Amps from a whopping 127 to 27, according to my Klein Amp Clamp! Run amps for "compressor only", stayed the same at 14 Amps, again, according to my Klein Amp Clamp. However, The Easy start App "Status" shows "Live Current" as 11 to 11.5 amps. Unclear if this "Live Current" is suppose to be compressor only or total Amps of compressor and Fan. For, I'm assuming the reasons the original poster stated above, I believe the Easy Start is showing lower running AMPs than actual running AMPs as read by my AMP Clamp. It's odd though, that the App is showing 30.4 as Inrush and my Amp Clamp has always showed around 27 (after Easy Start.) Anyway, my actual total Running Amp draw from Compressor and Fan should actually be around 16 AMPs. That would be 14 from the Comp plus 2 from the Fan. Which is right? IDK, but I like the product, for the intended purpose of lowering Inrush AMPs significantly. If your compressor kicks out but the condenser fan is still running, you can easily confirm this by checking the APP. Otherwise sometimes it can sound like the condenser is running normally when the compressor could be in thermal shut down. Plus, I like the delay in starting the Fan, then starting the compressor. This is the way all condensers should be designed. Lights don't flicker near as much when the AC kicks on!
@roadeomagic
@roadeomagic 2 ай бұрын
What do they mean by turn the thermostat to a lowest setting, do you mean you do not want to have the compressor running or kick in, in other words keep the heat very low and the AC very high so the compressor does not kick in, am I correct?
@theresatrickforthat
@theresatrickforthat 2 ай бұрын
The soft start gets power only while the A/C unit is on, and you really don’t want it to turn off in the middle of a firmware update. So with your thermostat in cooling mode, turn it down to temperature to force the A/C unit to stay running and not run the risk of it shutting off on its own due to satisfying the thermostat set point while you’re updating the firmware. Thanks for watching!
@roadeomagic
@roadeomagic 2 ай бұрын
@@theresatrickforthat can I have the unit running in heat mode since it's getting chilly or must it be cooling? Thanks for the info!!!
@theresatrickforthat
@theresatrickforthat Жыл бұрын
Watch the installation video of this Micro-Air Soft starter: kzbin.info/www/bejne/gIWchKprbKiNjqc Watch my start-up sequence video: kzbin.info/www/bejne/b4jcmpekpqpko5I Watch my 4-month follow-up review: kzbin.info/www/bejne/e5OUZIGAbZeYo68 Watch my amp draw comparison video: kzbin.info/www/bejne/l5SlgYOPqKyJiLM Watch all HVAC videos on my channel: kzbin.info/aero/PL-2uuHDasQcr286-RxHOT7s1wc1AOqEL6 Buy the Micro-Air Easy Start: amzn.to/3yrArSL I don’t drink coffee, all donations get 100% re-invested in the channel to bring more un-sponsored content for you. Please consider donating through this link as opposed to using KZbin Super Thanks since I get to keep more of your hard-earned money and less goes into the pockets of large companies like Google. You can also schedule one-on-one consulting/meeting with me here: buymeacoffee.com/theresatrickforthat For more options for RV A/C's and help visit Micro-Air's website: www.microair.net/ Affiliate Disclosure As an Amazon associate, I earn from qualifying purchases at no cost to you! Thanks for your support!
@LocLe-uo6vm
@LocLe-uo6vm 8 ай бұрын
What is the name of the app if you don't mind me asking? Thanks
@theresatrickforthat
@theresatrickforthat 8 ай бұрын
Just called EasyStart. Thanks for watching!
@jbhobbyist9372
@jbhobbyist9372 7 ай бұрын
What ton is your AC unit??
@theresatrickforthat
@theresatrickforthat 7 ай бұрын
It’s a 3 ton two stage unit. Thanks for watching!
@jbhobbyist9372
@jbhobbyist9372 7 ай бұрын
@@theresatrickforthat I installed Micro-Air on a 2 ton Trane yesterday. Your information has been very useful. Live current is 3 amps and start peak has been around 24 amps.
@theresatrickforthat
@theresatrickforthat 7 ай бұрын
@@jbhobbyist9372Awesome News! Glad I could help! You’re going to love you EasyStart!
@jbhobbyist9372
@jbhobbyist9372 7 ай бұрын
@@theresatrickforthat Thanks! Was wondering could you tell me what amps are listed for your LRA on the spec sticker that is on your ac. Would be helpful.
@theresatrickforthat
@theresatrickforthat 7 ай бұрын
@@jbhobbyist9372mine says 83
@richardy.
@richardy. 2 ай бұрын
Have one of these on my house and it blew up after 3 months. Would suggest people look at a different brand.
@theresatrickforthat
@theresatrickforthat 2 ай бұрын
And then there’s me who has had zero issues for multiples of years now. Just like everything, sometimes there are the lemons. Thanks for watching!
@maxwellcrazycat9204
@maxwellcrazycat9204 3 ай бұрын
Thanks. Just installed my Easy Start Flex on 9/16/2024. The app connected right away. This was very good information. I'm up to 7 starts without any faults. I will be try this with my generator power soon. GEN9500DF. Westinghouse using the 50AMP to power my whole house.
@theresatrickforthat
@theresatrickforthat 3 ай бұрын
Sounds like a good plan! Thanks for watching!
Save Lots of $$$! Micro-Air Easy Start on full-size A/C Review
7:45
There's A Trick For That
Рет қаралды 104 М.
It works #beatbox #tiktok
00:34
BeatboxJCOP
Рет қаралды 41 МЛН
Don’t Choose The Wrong Box 😱
00:41
Topper Guild
Рет қаралды 62 МЛН
We Attempted The Impossible 😱
00:54
Topper Guild
Рет қаралды 56 МЛН
Micro-Air EasyStart Home A/C Installation (368 Series)
23:01
MicroAir
Рет қаралды 282 М.
Microair EasyStart Bluetooth Android iPhone App Install
11:06
Hutch Mountain
Рет қаралды 17 М.
1 Hack To Eliminate Your A/C Power Bill This Summer!
11:52
There's A Trick For That
Рет қаралды 566 М.
Micro-Air EasyStart 368 Install on Trane XL16i 5-ton A/C
14:52
The ONE AC Upgrade Every Homeowner Needs to Consider!
18:32
How To Home
Рет қаралды 552 М.
Installing a Micro-Air EasyStart for Solar-Powered A/C!
26:40
Adam De Lay
Рет қаралды 3,7 М.
Micro-Air EasyStart ASY-368 5 Ton A/C Installation
9:27
Generator Superstore
Рет қаралды 74 М.
It works #beatbox #tiktok
00:34
BeatboxJCOP
Рет қаралды 41 МЛН