Earth Fault Relay Setting|| Impact of wrong Coordination for Earth Fault in Distribution System

  Рет қаралды 1,034

RELAY PROTECTION ELECTRICAL

RELAY PROTECTION ELECTRICAL

8 ай бұрын

Please use following link code for free subscription of udemy Course for Protection for Power Transformer
Code-
EB667EA4A5ADBF9D33BC
Link:-
www.udemy.com/course/protecti...

Пікірлер: 8
@surendrakverma555
@surendrakverma555 6 ай бұрын
Very good lecture Sir. Thanks 🙏🙏🙏🙏
@Technicalcobra
@Technicalcobra 4 ай бұрын
07:10 t= 172 or 129 as per IEC Standard inverse curve
@relayprotectionelectrical
@relayprotectionelectrical 4 ай бұрын
Thank You for watching video so patiently...you are absolutely right.
@prabhatsingh5377
@prabhatsingh5377 8 ай бұрын
Kindly make a video on how to calculate stablizing resistance value of motor feeder if motor data sheet values known . What parameters we consider for calculating rstab . Explain through example
@relayprotectionelectrical
@relayprotectionelectrical 8 ай бұрын
Thank you for your comment. My next video will be on Calculation of Stabilizing Resistance for Motor Earth Fault protection
@prabhatsingh5377
@prabhatsingh5377 8 ай бұрын
In Motor control centre if one outgoing motor feeder tripped on earth fault protection and in this feeder there is no earth leackage relay only OLR there . Then in that case whether incomer of mcc tripped or not ?
@Technicalcobra
@Technicalcobra 4 ай бұрын
One feeder in MCC tripped on earth fault..... but in this feeder not used any Earth Fault relay.. How it's tripped.....(1.) Tripped possible on phase over current if mv>sv with time set. (2.) Your question is 'Main incomer will be tripped or not'. Main incomer using the E/F or not...... if yes than it will tripped on preset value. If not using or not enable the E/F in your incomer feeder, than it will sence throw phase overcurrent, if fault current magnitude is greater than your set limit it will be trip, other wise fault current be circulate. (3.) If you used phase current unbalance protection...... that will be activated. (4.)
@great_India3344
@great_India3344 8 ай бұрын
Sir, What is the tripping time of LV side breaker? So in second case, fault at F2, F2 breaker seems to trip first. Kindly explain
Learn the basics of differential protection of Transformers
10:47
electrical engineerr
Рет қаралды 119 М.
8086 Microprocessor Architecture - Bharat Acharya
49:13
Bharat Acharya Education
Рет қаралды 1,4 МЛН
No empty
00:35
Mamasoboliha
Рет қаралды 10 МЛН
لااا! هذه البرتقالة مزعجة جدًا #قصير
00:15
One More Arabic
Рет қаралды 24 МЛН
Fast and Furious: New Zealand 🚗
00:29
How Ridiculous
Рет қаралды 45 МЛН
Earth Protection Coordination using ETAP II Earth Fault Relay Setting
24:11
Trip Transfer Scheme for Sub Station|| How trip is Transferred to TBC Breaker
10:02
RELAY PROTECTION ELECTRICAL
Рет қаралды 695
Relay coordination & Breaker tripping time calculations
7:17
Electrical Designing Basics
Рет қаралды 13 М.
Restricted Earth Fault Protection|REF relay working principle
11:56
ELECTRICAL TECHNOLOGY and INDUSTRIAL PRACTICE
Рет қаралды 140 М.
Stop, Intel’s Already Dead!
13:47
Linus Tech Tips
Рет қаралды 475 М.
Current Transformer (CT) Wiring Diagram for 11KV Switch Gear Panel
11:32
RELAY PROTECTION ELECTRICAL
Рет қаралды 1 М.
ELECTRICAL DISTRIBUTION SYSTEM
13:24
ArchEdu
Рет қаралды 41 М.