Earthing conductor calculation | Earthing Cable size | Earthing busbar calculation formula

  Рет қаралды 52,610

Electrical in Industry

Electrical in Industry

Күн бұрын

Пікірлер: 39
@transparentinfraandenergys5568
@transparentinfraandenergys5568 5 ай бұрын
YOU ARE DOING A GOOD JOB , MOST OF THE PERSON DOES NOT TOUCH IT
@electricalinindustry
@electricalinindustry 5 ай бұрын
Thanks keep watching ❤️
@adilakbar3053
@adilakbar3053 Жыл бұрын
Thanks for sharing informative material Sir
@electricalinindustry
@electricalinindustry Жыл бұрын
Thanks and welcome
@anonymus7387
@anonymus7387 11 сағат бұрын
This is the formula for cable sizing...not for sizing of earthing conductor. Please review.
@mdafsar5058
@mdafsar5058 Жыл бұрын
The above formula you have mentioned It is IS standard or British Standard
@electricalinindustry
@electricalinindustry Жыл бұрын
IS
@mdafsar5058
@mdafsar5058 Жыл бұрын
Thank you for reply, could you please provide earthing conductor formula according IEC or British Standard
@kakongkea7784
@kakongkea7784 3 ай бұрын
Dear Sir Please kindly check about the method value calculation conductor sizing I'm following the method calculation below: - (Isc=25kA, K=205 for Cooper Conductor, t=0.5Sec) * We can use formula ((S=Isc*√t)/K) Therefore, S= ((25*10^3*√0.5)/205) =86.23mm² (We can use select follow in the table we have conductor sizing 95 mm²) Many thanks so much!
@electricalinindustry
@electricalinindustry 2 ай бұрын
Thanks for watching dear, for calculation kindly check the example again in video for small correction.
@osst12
@osst12 6 ай бұрын
For home lightning arrestor, what should be the copper wire of down conductor?
@electricalinindustry
@electricalinindustry 5 ай бұрын
Dear it depends upon many factors.
@SURAJPATIL-vg7mc
@SURAJPATIL-vg7mc 4 ай бұрын
Bhai I value load current lete hai
@electricalinindustry
@electricalinindustry 4 ай бұрын
No, short circuit current
@mohitmeena1233
@mohitmeena1233 4 ай бұрын
Bhai aap pakistan Sai ho kya
@electricalinindustry
@electricalinindustry 4 ай бұрын
How may I help you
@Akshaypawar-un9wl
@Akshaypawar-un9wl 4 ай бұрын
Is there any standard you are using?
@electricalinindustry
@electricalinindustry 4 ай бұрын
This formula is based on IEC 60364 Standard
@panchalprashant8786
@panchalprashant8786 Жыл бұрын
Sort circuit cureent kese disid kre?
@electricalinindustry
@electricalinindustry 11 ай бұрын
Short circuit given hota h
@md.anisurrahman8708
@md.anisurrahman8708 5 ай бұрын
What is the reference of this formula?
@electricalinindustry
@electricalinindustry 5 ай бұрын
This formula is based on the IEC 60364 standard.
@transparentinfraandenergys5568
@transparentinfraandenergys5568 5 ай бұрын
LET US KNOW CABLE CONDUCTOR FOR LED LIGHTS INSTALLATIONS
@electricalinindustry
@electricalinindustry 5 ай бұрын
For LED lights installations, the earthing conductor size depends on the total current and fault current requirements. Here are some general guidelines: 1. For LED installations up to 10A: - 1.5mm² (14 AWG) earthing conductor is usually sufficient 2. For LED installations between 10A-20A: - 2.5mm² (12 AWG) earthing conductor is recommended 3. For LED installations above 20A: - 4mm² (10 AWG) or larger earthing conductor may be required However, it's essential to consider the following factors: - Total LED current - Fault current (if applicable) - Distance between LED drivers and earthing point - Soil resistivity (if earthing electrodes are used) - Local electrical codes and regulations
@transparentinfraandenergys5568
@transparentinfraandenergys5568 5 ай бұрын
DO COMPLETE CALCULATION WITH PICTURE
@electricalinindustry
@electricalinindustry 5 ай бұрын
Sure
@TasleemKhan-sp5xb
@TasleemKhan-sp5xb 5 ай бұрын
😢😮😮😮
@electricalinindustry
@electricalinindustry 4 ай бұрын
?
@transparentinfraandenergys5568
@transparentinfraandenergys5568 5 ай бұрын
COMPLETE THE VIDEO
@mdsadikhusain7007
@mdsadikhusain7007 10 ай бұрын
Sir If Someone ask me why time short Circuit 0.5 sec why not 0.10 sec what should be response?
@charylucky9981
@charylucky9981 9 ай бұрын
All the materials designed for more than 0.5sec solar ,as a thumb rule to avoid the damage we have to maintain 0.5sec
@electricalinindustry
@electricalinindustry 5 ай бұрын
The time value "t" represents the duration of the fault current in seconds. This is the time it takes for the protective device (e.g., fuse, circuit breaker) to clear the fault and interrupt the current. Typical values for "t" are: - 0.5 seconds (500 ms) for fast-acting protective devices - 1 second (1000 ms) for standard protective devices
@AjayKumar-ct6ok
@AjayKumar-ct6ok 6 ай бұрын
@electricalinindustry
@electricalinindustry 5 ай бұрын
❤️
@transparentinfraandenergys5568
@transparentinfraandenergys5568 7 ай бұрын
Unable to understand as nothing is clear about cable ie copper or ALLUMINIUM armoured
@electricalinindustry
@electricalinindustry 5 ай бұрын
Both can be use but the size calculation will be different as described in video kindly watch again ❤️
@manishkumargautam1654
@manishkumargautam1654 4 ай бұрын
Very boring topic
@electricalinindustry
@electricalinindustry 4 ай бұрын
That's why I explained this in very simple mannar.
@balindudhami2297
@balindudhami2297 4 ай бұрын
You must have basic knowledge
Busbar sizing
9:27
stephen brooks
Рет қаралды 138 М.
Cable Selection Method | Cable size calculation
13:08
Rashid iqubal
Рет қаралды 13 М.
Жездуха 42-серия
29:26
Million Show
Рет қаралды 2,6 МЛН
GIANT Gummy Worm #shorts
0:42
Mr DegrEE
Рет қаралды 152 МЛН
How to Calculate Earthing Conductor Size| Electrical Earthing | Hindi
5:42
Electrical With Abhishek Joshi
Рет қаралды 31 М.
Step to calculate earthing resistance value and Number of Electrodes Needed
13:14
Electrical Design Engineering
Рет қаралды 996
Три ошибки монтажа заземления
27:36
Стройплощадка
Рет қаралды 127 М.
Short Circuit Fault Level Calculation
7:06
Ratss AESQUARE ALL ABOUT ELECTRICAL ENGINEERING
Рет қаралды 177 М.
Cable sizing calculation|How to select cable size|Electrical Technology and Industrial Practice
22:27
ELECTRICAL TECHNOLOGY and INDUSTRIAL PRACTICE
Рет қаралды 167 М.
Жездуха 42-серия
29:26
Million Show
Рет қаралды 2,6 МЛН