I have now 2pcs. of the V4 JK. Some suggestions in generel: - Add both, the breaker to easily switch off the pack (or add a nice switch) and the fuse as last line of security (may be 300A fuse medium fast blow) - move the communication board to the middle, so the main power cables are not interupting with communication cables, status LED and setting switches - speak with JK that they have to add a better shunt which recognice also small amout of current flowing (my SoC is running away over time if the pack is nearly in idle) - I also miss the energy counter in communication protocol on JK as kWh I also have a V2 with Seplos (now spare/other use). This is a great one but was very harsh on current limit and need an active balancer addon. I saw from Jens (Meine Energiewende) that you now have the Neey Balancer option to add. Good choice! Looking forward for a round table with seplos and JK to find a JKplos :) Accuracy and communication protocol (Victron) from Seplos with overcurrent option, balancer, software, settings and app from JK packed in a case with main switch and fuse where I can see the communication board. I'm happy to get an upgrade kit to V6 :) Keep going, you do a good job in development!
@dermozart8023 күн бұрын
Also may
@danielmunnemann298722 күн бұрын
@@dermozart80 I have the older ones with 304A (1C) which is ok with pulsing, but with 2 Modules all is nice. I don't want stress the cells if it is not needed.
@OffGridGarageAustralia2 ай бұрын
With the change from a breaker to the fuse, you are now really reliant on external devices to disconnect your battery. Folks, get a descend battery disconnect for your system! Also, music is copyright?
@eelbatteryofficial2 ай бұрын
Hello, Andy, thanks for your feedback, we do not think this is a downgrade option. The JK BMS is a more advanced and intelligent circuit breaker. The fuse or circuit breaker is intended to remedy the BMS faulty situation, this happening is very small, and we found that the temperature rise of the circuit breaker when the current is too large is a hidden danger. Therefore, we think the ANL fuse is more practical. music is copyrighted.👍
@eelbatteryofficial2 ай бұрын
Hello, Andy, thanks for your feedback, we do not think this is a downgrade option. The JK BMS is a more advanced and intelligent circuit breaker. The fuse or circuit breaker is intended to remedy the BMS faulty situation, this happening is very small, and we found that the temperature rise of the circuit breaker when the current is too large is a hidden danger. Therefore, we think the ANL fuse is more practical. music is copyrighted.👍
@dlya_svoih2 ай бұрын
@@eelbatteryofficialwhat is the interrupt current rating of used anl fuse? Is it larger than 10 kA???
@eelbatteryofficial2 ай бұрын
@@dlya_svoih Our fuse specification says 125V DC 25KA
@CantFindInYoutubeАй бұрын
@@eelbatteryofficial Have the same opinion of Andy, and it’s not practical to have to disassemble most of the battery to replace a fuse, they also produce heat each of my T class 135A uses 25W, if is safer than the breaker put it outside the box. Will be nice if you have the fire extinguisher in the website has an option to upgrade previous box’s.
@Florian-w8i23 күн бұрын
Hi EEL, it's nice to see how you assemble the boxes. I'm still waiting for my delivery which I payed three month ago! But nothing happens .. why are you so slow? Will I still get what I've payed for or how can I get back my money to buy at a vendor who is more serious?
@Florian-w8i13 күн бұрын
Week 13 of waiting passed already but still no delivery. Folks be careful don`t pay these EELguys in advance! They promise 6 weeks delivery but give a shit on the customer waiting. That is so frustrating..
@jarodetparkerАй бұрын
I would like to buy the same red wire as in your video which goes from bat+ of the jk bms to cell 16. Thank you
@alpinerep2 ай бұрын
ANL fuses are typically only rated for 32V, not 58V. Shortcuts and cost savings should not be used on OCPD devices. This is disappointing to see.
@eelbatteryofficial2 ай бұрын
No, Our fuse specification is 125V DC 25KA
@alpinerep2 ай бұрын
@@eelbatteryofficial if true, that's impressive, kindly provide a manufacturer data sheet.
@eelbatteryofficial2 ай бұрын
@@alpinerep Please provide your email address or contact: Johnny@eelbattery.com.
@superpierrot2 ай бұрын
Hello, is it possible to order white V5 boxes please ? Thank you and keep up the good work. 👍
@eelbatteryofficial2 ай бұрын
@@superpierrot White is optional,thank you .
@stabby8882 ай бұрын
could a class T fuse be used instead of an ANL fuse?
@bess-trailers25 күн бұрын
The pricing landed to Countries in South East Asia still doesn't make sense given out economies compared to Western markets. We're still better off using slightly used ex-telco server rack batteries. The material quality is great but on a cost basis it isn't a fit.
@myyoutube66192 ай бұрын
3.2v x 16s = 51.2v ?
@eelbatteryofficial2 ай бұрын
The nominal voltage is like this, but it's usually called 48V
@myyoutube66192 ай бұрын
@eelbatteryofficial inverter 51.2 or 48v ?
@eelbatteryofficial2 ай бұрын
@@myyoutube6619 Yes, the inverter has a voltage range to choose from, and the battery type can also be selected as LiFeP04
@honumoorea873Ай бұрын
This fuse is not good enough for this application,, pretty sure the company that built those breaker isnnot serious. I've built my own boxes and use what we call in Europe a knife fuse, then a breaker for easy isolation if needed. In my opinion, that's how you should do it. The rest is pretty good inwould say, we can't see connectors between multiple packs and to the inverter busbar. The fuse should be near the positive pole, like 2 cm from it. Check the size of a knife 200A fuse, check how it is built, l1 for a knife fuse is over 100kA and that's what is needed here, a pack like that can generate thousands of amps if shorted. The fuse you use is ... not good enough.