Every publication I've read reserves C1 for access to live parts, so is a shock risk, but that is not the issue re that cooker, given the cover didn't appear to be damaged, so can be no higher than a C2, by their standards. Whether you should be coding it at all is a grey area, given it's probably more to do with In-Service Inspection & Testing, rather than an EICR, given it's arguably not part of the fixed wiring - yes, you can code it if desired but whether you should be is debatable.
@GSHElectrical7 ай бұрын
Thanks for the detailed response 👍🏻
@electrician2477 ай бұрын
I knew I left dinner in the oven to long! So good at cooking I can even burn the appliances 😂
@jasonwatson90117 ай бұрын
Found that nearly exclusively on that manufactures cookers. It's a bad design. When we fitted them you would tighten the cables, wiggle them and they would fall out. Despite the cord grip pulling out the appliance to clean and push it back repeatedly the terminals would pull out. If you over tighten they bend, under tighten they fall out. To be honest you have less issues over tightening them, if under tightend they usually weld themselves in with a high impedance connecting and continue to melt the connector. The appliance is usually repairable with that part readily available. I would C2 but disconnect it and make safe regardless.
@LeighWinspear7 ай бұрын
Interesting. In petrochemicals, we used to be involved in root cause analysis. Marcus gave his expert opinion and it got me thinking - if this actually caused a fire , how does it get investigated to determine the fault, post fire? Who or what team of people, are actually telling the insurance/owner/equipment manufacturer/media and fire brigade, what exactly went wrong? There must be a learning video in there perhaps. Luckily Ive never experienced a home fire situation but I know folks who have and It cant be a very nice process..............
@blobstrom7 ай бұрын
I'm assuming the internal wiring behind is also compromised and therefore cannot be repaired easily. I would be asking should a domestic oven be in a commercial environment, admittedly it has lasted a long time, but the manufacturers warranty often will not cover domestic appliances being used in a commercial premises
@GSHElectrical7 ай бұрын
Thanks for your thoughts 👍🏻
@stephencunningham88507 ай бұрын
Is condition reporting not just for fixed wiring
@deBoss19698 ай бұрын
Nice. As someone who only installs gas/electric cooking I see this regularly and it's always on the line conductor. Never seen the neutral burn out. My employer has dropped the coding from our procedure but c2 all day.
@GSHElectrical7 ай бұрын
Thanks for watching and taking the time to add your experiences in the comments
@LeighWinspear7 ай бұрын
Why has the coding been dropped?
@David-td1tf7 ай бұрын
Its burnt out because the resistance at that connection is high probably bigger cable will rectify.. had this problem on storage heater which had plug connection, removed plug and direct wired via fused unit sorted the problem.
@robertburrows66127 ай бұрын
I test up to the outlet to were the cooker is connected. when I PAT test, then I would check the terminal block on the cooker, and also note on the PAT sheet there is thermal damage and the wrong cable is being used and fault needs to be fixed without delay.
@giubaca6 ай бұрын
Isn't this fixed equipment?...
@tresslerj19857 ай бұрын
C2 with written information to the client and end user about a potentially dangerous situation. Leave it turned off.
@GSHElectrical7 ай бұрын
Thanks for the great comment 👍🏻
@EdwardBretherton8 ай бұрын
W hen taking ovens out it is always the neutral , never come across line melting , well apart from the dual fuel range wired in 2.5 twin💥
@deBoss19698 ай бұрын
I've seen a DF 100 range on 2.5 flex and a plug top...fml!
@GSHElectrical7 ай бұрын
Likewise 👍🏻
@EdwardBretherton7 ай бұрын
1100 mm df range wired in 1.5 twin and earth and piped in 10mm copper, taken out last week,
@Richardincancale7 ай бұрын
A bit of heat shrink will contract around that without even getting out the heat gun!!
@lewishumphries28934 ай бұрын
C2 . Making it clear to the client of the risk and potentially asking for a signature of acceptance
@carvanplace7 ай бұрын
C2 is what i said in your shorts video. Shame it takes you a long time to reply back. Good video though..👍
@GSHElectrical7 ай бұрын
Sorry I have tons of messages across all social media channels GSH & eFIXX
@scotisland7 ай бұрын
C2 but oven not OK to be in service, new terminal block or new oven.
@drewbarton702413 күн бұрын
Should of used a heat resistant 6mm cable
@GSHElectrical13 күн бұрын
👍🏻
@Cardetailingburnley7 ай бұрын
I think looking at this c2
@bankraid21837 ай бұрын
Make a note on the report
@ChrisTheSparky7 ай бұрын
No earth sleeve that's a DIY job all day long
@GSHElectrical7 ай бұрын
We were hoping someone would spot that Chris 👏🏼
@SSSwilliams8 ай бұрын
Shared 👍 c2 then go down the pub😂
@GSHElectrical7 ай бұрын
🍻
@Davidhughes94677 ай бұрын
C1 all day that insulation on the line has broken which is exposing the live conductor
@GSHElectrical7 ай бұрын
Thanks for your thoughts 👍🏻
@CellAmen7 ай бұрын
C1
@themagpie_17 ай бұрын
all i can see is no cpc and a snipped haircut.. there is also a nic in the outer insulation approx 300mm down the line
@David-td1tf7 ай бұрын
I spotted that aswell
@martinnixon20797 ай бұрын
It’s a C1 clearly a danger to use. But good find as most electricians wouldn’t remove a free standing cooker just in case you damaged the flooring. We would either disconnect it or charge to replace the connection unit.
@caphaenaddiction7 ай бұрын
I ignore the exposed live parts as the only C1 description and C1 something if it’s an immediate or imminent danger to life. Sue me, I’ll stand in front of the 3 chairs and curly wigs and state my case without any fear.
@sergiofernandez37257 ай бұрын
C1 Themal damage to cable in connector block Possible damage on the terminal Discolouration around the outside of connector block possible thermal Looks like physical damage to cable about 200mm down from connector block Possibly the wrong cable type used (T&E) need to check MI as it may need H07 flex...Caveat Oven MI vs Cooker plate MI Possibly appliance faulty and may be dangerous to use Is that CPC sleaved? Other things to consider Carbon monoxide alarm present in room and In Date IF there is a Gas burning appliance Heat detector in room and In Date Is that rotary switch isolator directly underneath a deep fat fryer????
@stratvm7 ай бұрын
3:02 the neutral is connected to a phase slot (3) instead of the neutral slot (N).
@tonywatson14127 ай бұрын
It seems these days we are so lacking in knowledge and common sense, that numbers and letters must be used .... probably because of litigation etc...all the paperwork and quadruple BS...etc....its like everything must be explained to kids....Makes you wonder...