Electrical Conduit vs. Cable: Which is best for your project?

  Рет қаралды 50,535

Practical Home Projects

Practical Home Projects

Күн бұрын

Пікірлер: 27
@usmarinekenny
@usmarinekenny Жыл бұрын
Just a correction, if it is rigid metal galvanized conduit it has to be buried 6” below grade and that’s to the top of the conduit not the bottom as that confuses people. And pvc is generally 18” to the top of the conduit with the exception of if it’s 120 volts circuit and gfci protected before it comes outside and goes into the ground can be buried at 12”. Now with that said using the flexible conduit buried in the ground is kind of a gamble as the whole subject to physical damage thing comes into play which is why they require even rigid pvc to be schedule 80 thick wall pvc when exiting the ground up to 8’ and down into the ground 18” if I’m not mistaken. It all depends on the inspector and if he interprets it to be in a physically damaging area. To avoid hitting it and breaking through it with like weed eaters and lawn mowers specifically the weed eater with the metal blade instead of the string, but just a safety thing. Just throwing some info at you. But I like your videos. Keep up the good work.
@practicalhomeprojects
@practicalhomeprojects 11 ай бұрын
Thank you for the insight. The "Subject to Physical Damage" piece is a bit subjective, so it's a great idea to speak with your local inspector. Ours told us that for a residential property we'd be fine with schedule 40 as long as it wasn't next to the driveway.
@karenderuyter2568
@karenderuyter2568 2 жыл бұрын
Thank you for clearing that up for me.
@practicalhomeprojects
@practicalhomeprojects 2 жыл бұрын
Glad it helped!
@danhdo8233
@danhdo8233 Жыл бұрын
I've been watching ev charger or nema 14-50 for tesla charger video installing and couldn't find any video explaining in details like yours. Especially the Non Metallic Liquid Tight Flexible Conduit. I am planning running it from electric panel down to crawlspace (20ft) then outside for another 50 ft using this type of conduit. Then bury the gray PVC schedule 40 for burying 18" under the ground. Now I know NMLFC an be buried like a pvc. Learned something!
@MrRicker9
@MrRicker9 Жыл бұрын
Some good info here, but......per the NEC you CAN NOT use THHN wire in an outdoor/underground application. It is rated for dry use only. Underground in conduit is considered by the NEC as a damp/wet location. This requires THWN rated wire. Typically you can buy dual rated THHN/THWN-2 wire.
@practicalhomeprojects
@practicalhomeprojects Жыл бұрын
Hi there. You are correct that the wire needs to have the "W" to be used in outdoor settings. I labelled it as "THHN/THWN-2" at 1:12, but I tend to just refer to it as THHN since almost all of the THHN wires on the market today are dual rated. Thanks!
@johndavies2949
@johndavies2949 Жыл бұрын
It always comes that way. Thhn/Thwn
@Ricko1962
@Ricko1962 Жыл бұрын
Great video, thanks!
@practicalhomeprojects
@practicalhomeprojects Жыл бұрын
Glad you liked it!
@danmoore1088
@danmoore1088 Жыл бұрын
Really helpful, thanks!
@practicalhomeprojects
@practicalhomeprojects Жыл бұрын
Glad it was helpful!
@candlemedia
@candlemedia Жыл бұрын
Veryyyyy informative. Thank you. If one wanted too, can they use the flexible pipe from the outside of a house that runs 50ft straight & buried 18" in ground and out to a supposed outlet which has romex 12gague running thru it? You've mentioned not running romex in the flex pipe but running single THHN wire, but why can the romex yellow jacket (hot, neutral and ground) run?
@practicalhomeprojects
@practicalhomeprojects Жыл бұрын
Hey there. You could run the romex inside, then switch to THHN inside conduit at a junction box. It's not completely forbidden to use romex in a conduit, but there are two issues: With 3 or more conductors, the total fill inside the conduit cannot be more than 40%. The romex has a much higher cross sectional area than the individual cables inside, so you'd have to oversize the conduit significantly. The second issue is that the pvc jacket around romex is actually a bit tacky and will have a lot of friction when pulling through a conduit; it's not very durable either so it may tear. The THHN cables are a slick nylon material. Hope this helps!
@nCon808
@nCon808 5 ай бұрын
Great video, man! I wanna install a 30amp power inlet for a generator to power my house after a power outage. I’ll probably use 50-60 feet of wire that runs from the back of my house to the front (where main panel is located). Given the scenario I’ve mentioned, what type (brand?) and gauge wire and what type of conduit should I use? Or if you could give me a full list of what I’ll need that’d be great😅
@practicalhomeprojects
@practicalhomeprojects 5 ай бұрын
I think this article will answer most of your questions. practicalhomeprojects.com/?p=138 The brand of your wires/conduit isn't important as long as they are UL rated for the application. Since it is outside, everything needs to be rated for wet areas.
@OthmanAlikhan
@OthmanAlikhan Жыл бұрын
Thanks for the video =)
@practicalhomeprojects
@practicalhomeprojects Жыл бұрын
You are welcome!
@aaronho673
@aaronho673 Жыл бұрын
Very helpful!
@practicalhomeprojects
@practicalhomeprojects Жыл бұрын
Glad it was helpful!
@samijames9986
@samijames9986 2 ай бұрын
very informative video. However, at timestamp 1:52 the cable you're showing has 4 wires and that's not comparable apples-to-apples to the cable you're showing at timestamp 0:45, which has only 3 wires. Most outdoor use cases only nee 3 wires, unlike indoor use cases, like 3-way circuits, which require 4 wires.
@practicalhomeprojects
@practicalhomeprojects 2 ай бұрын
Hello, The number of wires would depend on what kind of circuit you are setting up. You should be able to find 3 or 4 wire cables meeting either indoor or outdoor conditions.
@b3arwithm3
@b3arwithm3 5 ай бұрын
Nice overview mate. I have a panel outside of my garage. I want to install an EV charger inside the garage. Would I insert the blue conduit inside the wall that is between the charger and the panel? What is the easiest option?
@practicalhomeprojects
@practicalhomeprojects 4 ай бұрын
I think your plan sounds reasonable. The blue conduit can only be used indoors and is a good way to protect individual conductors. Be sure to use proper fitments at the panel and junction boxes.
@vince6829
@vince6829 Жыл бұрын
Thanks for sharing
@karimiHSE
@karimiHSE Жыл бұрын
Very good 😮😮😮
@jimsummers487
@jimsummers487 Жыл бұрын
Electricians manage heat so that you have a cool running electrical system….fire code requirements are minimum standards…… A majority of you will need fire extinguishers
How to bend and install electrical conduit
20:14
Bob Clarizio
Рет қаралды 1,4 МЛН
Metal Vs Plastic Electrical Boxes | Avoid This Common DIY Mistake
13:21
Everyday Home Repairs
Рет қаралды 850 М.
黑天使被操控了#short #angel #clown
00:40
Super Beauty team
Рет қаралды 61 МЛН
Don’t Choose The Wrong Box 😱
00:41
Topper Guild
Рет қаралды 62 МЛН
#1 UNKNOWN Conduit and UF Cable Rule you Need to Know! Electricians In Action
8:46
Different Types of Romex Wire or NM Electrical Cable
12:06
Phillip Bridges
Рет қаралды 133 М.
Electrical Conduit: Types and Uses
4:57
RSP Supply
Рет қаралды 298 М.
Watch This Before Buying Conduit
4:02
Maker Pipe
Рет қаралды 9 М.
6 Electrical Code Myths people Should Stop Believing
10:14
Backyard Maine
Рет қаралды 105 М.
How to Wrap Cables Like a Pro: Over/Under (Roadie Wrap) Method Explained!
14:59
Rattlesnake Cable Company
Рет қаралды 96 М.
CUT cables under voltage! Proofwood
17:03
ProofWood
Рет қаралды 27 М.
#1 DIY Electric Mistake - Can you use Romex Wire in Conduit?
3:44
Silver Cymbal
Рет қаралды 1,2 МЛН
黑天使被操控了#short #angel #clown
00:40
Super Beauty team
Рет қаралды 61 МЛН