How to bend and install electrical conduit

  Рет қаралды 1,345,106

Bob Clarizio

Bob Clarizio

Күн бұрын

Before I was a builder I spent many years as an electrician and roughing in and bending electrical conduit or EMT for new construction. A few weeks ago I decided to film a how to video about the basics that I use when bending conduit for a new construction house.
How to install an outlet at home
• How to install an outl...
How to wire a three way light switch
• How to wire a three wa...
How To Replace A Light Switch
• How To Replace A Light...
websites
theinshed.com
bantambuilthom...

Пікірлер: 1 400
@davenag957
@davenag957 3 жыл бұрын
A few tips from a guy bending in Chicagoland since 1977. Loose the loaded toolpouch when running pipe. You don't need all that weight slowing you down. All you need are uninsulated 420 channelocks, a screwdriver with a Klein reamer attached, tape measure, pencil and 4 pocket nail apron. You want to be able to work light and fast and have everything you need right in that nail apron. Using a marker is bad for exposed work as it bleeds through paint and you're always having to take the cap off and on the marker which slows you down. Upgrade to a small battery impact for mounting boxes and tightening fittings. Wear sturdy shoes or your right foot will kill you at the end of the day from the bender. Get a short radius bender as you may need it for close quarter work. I used a hand hacksaw thirty-plus years. It killed my shoulder. If you're going to do a lot of this get yourself a small metal cutting circular saw such as a Bosch or Makita. It really speeds up the job and saves your body. After a while the math gets easy so strive to do the numbers in your head. Avoid coming into the side of any switch boxes. The fittings extend into the box and will obstruct any large size dimmers or timers that you may want to install later, especially if you're going to have a 2 Gang installation. I try to just use top and bottom knockouts everywhere. Switch boxes should be 2 1/8 in deep instead of the standard inch and a half deep 1900 bracket box. They cost a little more but you have more room in the box for dimmer's, timers and more wires that are required with multi-location switches. Believe it or not you can put in 400 or 500 ft 1/2 inch thin wall a day once you're proficient at it. Try to make it look good even though it's going to get covered with drywall. Inspectors love to see good pipe work as it's a key indicator that you know what you're doing.
@davenag957
@davenag957 3 жыл бұрын
I forgot the hammer!
@aaron74
@aaron74 3 жыл бұрын
You Chicago guys are great, I love to see EMT and wish the rest of the country followed your high standards
@jimpie231
@jimpie231 3 жыл бұрын
@@aaron74 My brother lives in Charlotte, NC and they do not use conduit. However all commercial industrial sites do. When building a home there, you can pay extra and have it done. If you do this also ask for home run electrical from the panel to the first outlet or light. Good luck….Jim PS….I live in a Chicago suburb.
@christiancassini768
@christiancassini768 3 жыл бұрын
What do u mean about the home run to 1st outlet or light. Like one circuit per pipe? That would be VERY expensive and take up a LOT of room in the walls.
@steveloux4709
@steveloux4709 3 жыл бұрын
@@christiancassini768 he means that it is quite common to take a conduit from the panel and route it to a given area and star out from there with another wiring method. Normally this approach would involve installation of multiple home runs in the same conduit (using dedicated neutrals and THHN/THWN you could install up to four 20 amp circuits in one conduit before de-rating the circuit).
@dreadheaddj5921
@dreadheaddj5921 Жыл бұрын
im an electrician and ive been watching youtube videos just to re learn what i forgot & you are amazing a guy that actually knows what he's doing and talking about
@Teampierrellc
@Teampierrellc Жыл бұрын
Awesome to see an electrician not being extra critical for a change.
@provethioaltum3276
@provethioaltum3276 Жыл бұрын
Same bro
@HelloDapp
@HelloDapp Жыл бұрын
Great video! Electrician here as well. Just a little 2 cents for anyone interested; since he was using 1/2 inch pipe, the take up (or deduction, the part you subtract when bending a 90 on the arrow) was 5". However, keep in mind, that these change from size to size. So if you're using 3/4" , the deduction is 6". If you're using 1", the deduction is 8". As he said in the video, it will be listed on the bender. Also, if you don't want to do the deduction, you can do something called "bending on center". Usually this is denoted on the bender by a star, and this allows you to just mark your exact measurement, and line the mark up with the star, as opposed to the arrow. Just a little less math involved is all. I work mainly commercial, but most of this information was very useful for anyone just starting off/doing a home project. This is stuff i only learned after being at many sites. I've never seen those bracket 1900s though, those are pretty nice!
@robm3063
@robm3063 Жыл бұрын
I hated using the arrow. I used a scrap pipe and measured the 90 from the end of the shoe. My bendfield is exactly 6 inches.
@foxgood
@foxgood Жыл бұрын
Too much information for beginners, I'm an electrician myself, a lesson in how to bend conduit can go a long way. an offset of 15 degrees, you multiply the height of your offset by 3.8 an offset of 30 degrees, you multiply the height of your offset by 2 an offset of 45 degrees, you multiply the height of your offset by 1.4 example for an offset of 3 inches at 30 degrees you multiply 3'' X 2 so it will be 6 inches in both marks where the conduit will be bent at 30 degrees.
@HaroutBlack
@HaroutBlack 10 ай бұрын
Jesus is the only way to healing, restoration and salvation to all souls. Please turn to him and he will change your life, depression into delight, soul heading from hell to heaven all because of what he did on the cross “Whoever calls upon the name of the Lord shall be saved” Romans 10:13
@Jumaforever
@Jumaforever 2 жыл бұрын
Thank you for showing your mistakes and fixing them.
@orbitring
@orbitring 2 жыл бұрын
Even, the most skilled in the Trade make mistakes. I know; I have seen it.
@RodricKing
@RodricKing 5 ай бұрын
❤🎉I agree. Great teacher.🎉❤
@vobinh5456
@vobinh5456 9 ай бұрын
Hello, I am a civil electrical and water construction repairman in Vietnam, I really admire your work. I have learned many things about electrical system construction techniques that you have instructed on this KZbin channel. Wishing you good health and success
@ncameron7
@ncameron7 2 жыл бұрын
The name 1900 Electrical Box comes from the part number given by the Bossert Company almost a hundred years ago.
@scottsmith4430
@scottsmith4430 3 жыл бұрын
Great job. I retired from the trade after 50 years. Worked on everything from 115k on down to 24vdc. Had a great time too. Take care and best of everything.
@Joe-qw6il
@Joe-qw6il 2 жыл бұрын
No one ever tells good honest tradesmen thank you, where would we be without your service, thank you.
@rayjackson4547
@rayjackson4547 2 ай бұрын
Bob- I am a carpenter, contractor and home inspector. I learned a lot of little trick from you Nice job explaining.
@BobClarizio
@BobClarizio 2 ай бұрын
Thanks! How long have you been an inspector?
@rayjackson4547
@rayjackson4547 2 ай бұрын
@@BobClarizio Bob- I have been inspecting homes for 35 years. It was a great business up until the housing shortage. Buyers are foolishly buying homes with out pre inspections. In Massachusetts home inspectors are off by about 60%!
@BobClarizio
@BobClarizio 2 ай бұрын
@rayjackson4547 60%?!? Wow that’s crazy
@thatroll1
@thatroll1 3 жыл бұрын
Nice and concise. I, as an apprentice struggle with efficiency and its nice to see someone finally describe a good workflow.
@sngclue2246
@sngclue2246 2 жыл бұрын
Because you don’t have a plan
@Wingsabr
@Wingsabr 2 жыл бұрын
I wouldn't take to much from this guy tbh. He's got the ethics correct, but the execution is a bit lacking.
@trackdork444
@trackdork444 2 жыл бұрын
This is one of the best tutorials. So many show everyone going right and make it simple looking. He shows what can go wrong and how to fix that. Because I know I'm going to run into so many problems.
@mrobviousj
@mrobviousj Жыл бұрын
I'm an attorney and do minimal home repair/maintenance/construction. This video is so easy to understand and your method of showing/explaining the process each step of the way is top notch. Honestly, after 20 minutes of watching, I feel like I have some semblance of how to run some short conduit without giving up before the project was even attempted (obviously I'd likely get an electrician to handle much bigger projects). Great job and keep up the good work!
@Logan-zi4vx
@Logan-zi4vx Жыл бұрын
Your comment wouldn’t have made any sense if you left out that you’re an attorney, so I’m glad you let us know right away
@mrobviousj
@mrobviousj Жыл бұрын
@@Logan-zi4vx I could have just as easily said "I work on computers all day as a computer programmer" and the end result would be the same- I don't normally do a lot of manual labor so that detail gave context but, as seems to be your prerogative, let us all see your fragile ego by focusing on one word rather than an entire paragraph of text!
@Logan-zi4vx
@Logan-zi4vx Жыл бұрын
@@mrobviousj what part of what I said made me seem like I have a fragile ego?
@Logan-zi4vx
@Logan-zi4vx Жыл бұрын
@@djderekrock why
@inthedarkwoods2022
@inthedarkwoods2022 10 ай бұрын
What does being an attorney have to do with your comment?
@mr.g5963
@mr.g5963 6 ай бұрын
That's pretty boss you called yourself out on that small mishap with the conduit... RESPECT!! Showing how to measure the bend properly is going to be very helpful...ty. I've just been eyeballing it, and believe me, alot of wasted time having to recut
@BobClarizio
@BobClarizio 5 ай бұрын
Thanks 👍
@boing675
@boing675 3 ай бұрын
I want to get into this. Im tired of doing nothing in my life. I wanna feel accomplished and do work that makes me feel good that I or we did this. On monday im going to a school for electrical work. Im gonna make a difference in my life. I want change..
@BobClarizio
@BobClarizio 3 ай бұрын
That’s so awesome to hear! I’m glad you’re going to finally make it happen! How long have you been thinking about it?
@mookfaru835
@mookfaru835 21 күн бұрын
Good job buddy. Off the net and onto your feet.
@jstone1211
@jstone1211 Жыл бұрын
so nice to see a pro admit he missed it...then showed how to fix it. that is my life, fixing my little mistakes. I have a job that I need to use EMT....looks easy enough..(LOL)
@Dynamice1337
@Dynamice1337 3 жыл бұрын
Those shallow boxes really cramp my style. I always use deep 4s boxes, 2-1/8" deep. They cost a bit more but the extra room is golden for installing dimmers and GFCI's
@curtstrenk9257
@curtstrenk9257 2 жыл бұрын
The deeper the better in my opinion
@customsolutions7167
@customsolutions7167 10 ай бұрын
Always go as deep as possible ....😂
@funnyharleyman
@funnyharleyman Жыл бұрын
I’m retired now but for years (and still do) I have a 12volt Milwaukee powered hacksaw, it’s small and light. Hand hacksaws are disappearing. I’ve seen some of the new guys coming up using small battery bandsaws! And I always use 1900SPD (deep boxes) for switches and a given for GFI’s, for the small price difference they give you extra room and less of a headache. Also, when your done, step back and look at everything, better to change it now than when the walls are rocked.
@bmwIdrive1
@bmwIdrive1 2 жыл бұрын
Than you much. You provided the exact information I needed to run conduit between the studs. The time you took to make this video and share it will open doors to other successes in your life’s journey. Thanks again.
@HaroutBlack
@HaroutBlack 10 ай бұрын
Jesus is the only way to healing, restoration and salvation to all souls. Please turn to him and he will change your life, depression into delight, soul heading from hell to heaven all because of what he did on the cross “Whoever calls upon the name of the Lord shall be saved” Romans 10:13
@nealheardjr9463
@nealheardjr9463 Жыл бұрын
Thank you man, i knew conduit bending but you explained the whole process from bracket box to installing conduit. Youre a good guy.
@Ramanylifts
@Ramanylifts Жыл бұрын
Great stuff! Just started my apprenticeship, and it helps to see all of this to study off of! Thanks man
@JH-em8qq
@JH-em8qq 2 жыл бұрын
Thank you all of you...I learn something. Gratefully yours
@raphaelsanchez4797
@raphaelsanchez4797 Жыл бұрын
You are not just a masterful technician, you are a masterful teacher. Thank you!
@ybeykoz
@ybeykoz 2 жыл бұрын
whoever built that shed, they did an excellent job looks like. they built that like a house, more than a shed which is awesome.
@bocaveli7
@bocaveli7 3 жыл бұрын
Great video. I like that you showed the hiccups also and what to learn from for someone that has never done it. I wouldn't worry about talking slower. It's a video so we can always pause, rewind, but slow deliveries take forever to get through. Wouldn't change a thing.
@BobClarizio
@BobClarizio 3 жыл бұрын
Thanks 🙏
@hansolavrkkennordland9534
@hansolavrkkennordland9534 2 жыл бұрын
TV2
@philliprgarcia
@philliprgarcia Ай бұрын
I am learning how to add an extra power outlet in my garage as I only have two on two walls but need one on the third. This video was helpful. thank you.
@davidthorne5715
@davidthorne5715 2 жыл бұрын
Full respect, I don’t do it much with the company I work for now, but I love running conduit, so satisfying to look at when you’re done.
@claytonmiller63
@claytonmiller63 8 ай бұрын
That was an excellent job in illustration of working with emt!!!!! I have been electrician for the past 51 years and electrical contractor for past 48 years. You impressed the hell out of me!!!! Why didnt you just simply run mc cable??? I prefer 420s, (they are tad smaller), the klein conduit reamer/screwdriver, tape measure, pencil, hacksaw (battery sawzall, or hacksaw), 1/2" bender and little kicker to do that job in emt if the inspector refuses to allow me to use mc cable which is alot faster than emt is!!!! Again a great job!!!!!!
@grumpy_ken
@grumpy_ken 2 жыл бұрын
great video! I was on a construction site for the first time as a welder, but I really enjoy doing electrical now also. really good explanation of what you're doing
@HaroutBlack
@HaroutBlack 10 ай бұрын
Jesus is the only way to healing, restoration and salvation to all souls. Please turn to him and he will change your life, depression into delight, soul heading from hell to heaven all because of what he did on the cross “Whoever calls upon the name of the Lord shall be saved” Romans 10:13
@I-K
@I-K Жыл бұрын
Interesting to see how a simple shed electrical is complicated af in some states. Im glad in our state (virginia) (Fairfax county) code allows for SIMpull romex, requires 1/4 of the time as this work and cheaper too. I will argue that it's almost as safe. Still a very good tutorial.
@customsolutions7167
@customsolutions7167 10 ай бұрын
Yeah that's the way to go ..moved from Chicago hard pipe to Missouri romex .. will never go back ...😂😂😂
@INRIKingOfKings
@INRIKingOfKings 3 жыл бұрын
Good tutorial. I know a lot of people use the conduit for the ground. But I always pull a green wire in as well. But then, I have a lot of industrial background. I retired 7 years ago after many years of working with 480 and below.
@Eric-hk5hz
@Eric-hk5hz 3 жыл бұрын
I agree. Its legal, but never rely on the conduit to carry the ground. Pull a ground.
@bmay8818
@bmay8818 2 жыл бұрын
I don't know why anyone would use the conduit for the ground, even though it's code. Sure, wire isn't cheap, but it's the better way to do it.
@r777v
@r777v 2 жыл бұрын
Just FYI code says EMT SHALL BE allowed to be used as ground. I have worked exclusively commercial and industrial. With today’s costs you are screwing yourself. I’d sooner put money into ground pigtails.
@INRIKingOfKings
@INRIKingOfKings 2 жыл бұрын
@@r777v Yes, I know the code allows it but have had far too many seriously bad ground situations because of EMT couplings loosening or corroding. I had a very deep maintenance budget too.
@anthonyshelley6083
@anthonyshelley6083 2 жыл бұрын
When I'm taking my measurements I usually deduct 1/8" or 1/4" for where the pipe goes in the connector. Most connectors don't let the pipe go in exactly to the edge of the box.
@nicolesavage4775
@nicolesavage4775 2 жыл бұрын
he helped me through high school ! Thanks mark! Me and the fam love ya!
@jcoors8790
@jcoors8790 2 жыл бұрын
Great video, Thanks. It's too bad all contractors and laborers don't have the professional attitude and dedication that this guy has.
@chris_aguy2141
@chris_aguy2141 6 ай бұрын
Just some useful info from an apprentice from Chicago. If you're gonna be doing a lot of pipe work you should get a 12v bandsaw to cut your pipes much faster, a 12v impact driver to drive your screws in your couplings/connectors faster, and put a Reaming Bit Holder on your impact, extremely useful bit it will save you time on reaming. If found that sometimes bending on the star is faster in certain situations like for a long piece of pipe (also you don't need to subtract if you're using the star) Nice video though!
@PSNDeezNutzDrill
@PSNDeezNutzDrill 3 жыл бұрын
To give you the answer. The term 1900 box comes from the original listing given by the Bossert Company for the 4” x 4” x1 1/2” gas and electrical box and the name never changed. The listing goes back over 100 years ago.
@davenag957
@davenag957 3 жыл бұрын
Very true. I was hanging a new ceiling light in a Chicago building from 1902 when I was young and when I removed the black pipe cap that the box was hanging on the gas was still live!! A lesson learned that I will never forgot!
@davidsafranek4747
@davidsafranek4747 Жыл бұрын
Really good video! Not that many out there on conduit. I live near Chicago and everything here needs to be in metal piping and boxes....no romex. I have been doing it for years but your video still helped me learn some new tricks. Thanks!
@southwestoff-grid285
@southwestoff-grid285 3 жыл бұрын
Failed inspection for hole size where I live. Best practice is to Stay under 1/3 the thickness
@chrisstovall7329
@chrisstovall7329 Жыл бұрын
Yeah that was my only heartburn with an otherwise great video. The electrical code does spell out that there has to be at least 1 1/4" from the edge of the hole to the outside edge of the stud. (300-4 (a)(1) I believe) So per the Code in a standard 3 1/2" stud you can't go larger than a 1" hole without using a nail guard over the hole. BUT, nail guards are cheap and having the bigger holes makes it a lot easier to get the conduit in and out of the wall. I would do exactly what he did and just slap a nail guard over those 5 studs for like $3. Lol
@nevinkuser9892
@nevinkuser9892 Жыл бұрын
I would make precision holes with a laser level.
@freema22
@freema22 8 ай бұрын
Learn something every day. I never thought about the galvanic corrosion that would occur with screws
@garbo8962
@garbo8962 2 жыл бұрын
I would have used a deeper box ( 2 1/8" deep ) just to give a little more room. Somebody told me years ago the 11/2" deep boxes that you used are called 1900 boxes because they are 19 cubic inches. I always pull a ground wire in every metal conduit. Saw way too many conduits that pulled apart that would cause most of ground if no ground wire was pulled. Great ideal not using sheet rock screws to secure box.Klein makes a great screwdriver with a teamed on it. Have several that are over 40 years old and never had to replace the steel blade. Installed miles of conduit in industrial sites but only a few times thru just 1 or 2 holes in stud or joist. In industrial sites the only time we used 1/2" EMT conduit was for alarms. 3/4" conduit is a lot stronger and provides some room for future circuits. Great ideal putting the notches in home made step stool to hold conduit.Would try to keep edge of hole 11/8" from front of stud like is required for Romex cable. Must seal all wires coming from a cold location to a warmer location to prevent condensation building uo.
@danlux4954
@danlux4954 2 жыл бұрын
I read that 1900 was the part number given by the Bossert Company almost 100 years ago.
@edwardsmith4353
@edwardsmith4353 2 жыл бұрын
It's only 2x3 studs you know....
@mikeryan6277
@mikeryan6277 2 жыл бұрын
@@edwardsmith4353 thought they were 1 1/2 X 3 1/2
@edwardsmith4353
@edwardsmith4353 2 жыл бұрын
@@mikeryan6277 my point was that his figures apply to ordinary studs which are listed as "2 X 4's". These studs are clearly 2X3's (which are slightly less than 2X3).
@vince9051
@vince9051 2 жыл бұрын
@@danlux4954 it was also the UL listing number from back then and still is UL part# 1900
@UAND154
@UAND154 Ай бұрын
Great jobs and sharing valuable information of how to set up electrical metallic tubing and how to measure and bending ! Thank you so much..
@OriginalMerk1904
@OriginalMerk1904 2 жыл бұрын
Its always interesting to see a non electrician teach electrical or electric as he calls it.
@TooKool70
@TooKool70 2 жыл бұрын
I know, right? I like how he didn’t even check his 90° by adding a level on it 😂
@OriginalMerk1904
@OriginalMerk1904 2 жыл бұрын
@@TooKool70 factz. He said when it looks straight its straight.
@stephen1193
@stephen1193 5 ай бұрын
@@OriginalMerk1904 that 90 definitely wasn't straight
@alexmasso6759
@alexmasso6759 Жыл бұрын
Thanks Brother! I feel empowered to go get it done!
@RonSch123
@RonSch123 3 жыл бұрын
In EMT land here near Chicago as well. Try the angled side of a cats paw to knock out, then use the straight end to remove it on the inside of the box. I accidentally found this trick and will never go back. Hope this helps another electrician.
@jimpie231
@jimpie231 3 жыл бұрын
What’s a cats paw? Thanks…Jim
@RonSch123
@RonSch123 3 жыл бұрын
@@jimpie231 Carpentry tool. Google will pull one up pretty quickly for you.
@gerdberg4188
@gerdberg4188 3 жыл бұрын
So …. You carry a cats paw just to pop knockouts ? Seems to be a lot of weight for minimum function .
@austincoz364
@austincoz364 2 жыл бұрын
Just use lineman pliers. Use them as a hammer. Use the to knock out knock outs. Use them to remove the knockout. Use them to make up the box. Why do you all make this so hard lol
@scottlandb6579
@scottlandb6579 Жыл бұрын
Dang dude this was awesome. Took me back to my early years in electrical. Wish you would’ve pulled wire hooked up some outlets/switches etc. but it was cool to watch so well done 👍🏼
@customsolutions7167
@customsolutions7167 10 ай бұрын
I would have liked to see him go up into the rafters for the lights and around the corners to the boxes on the other walls.. 😂😂
@austincoz364
@austincoz364 2 жыл бұрын
Thank you Chicago, for turning a 1 hour job into a 4 hour job. 👍
@customsolutions7167
@customsolutions7167 10 ай бұрын
Hey that's the least amount of trouble chi town has caused..😂
@markwoten6679
@markwoten6679 2 жыл бұрын
Never had to run conduit but getting ready to do my garage.
@mathiastwp
@mathiastwp 2 жыл бұрын
Seems like a lot of work compared to how we do it here in Norway. We use hammer-on boxes and pre-fed flexible conduit; much easier.
@davidboman7395
@davidboman7395 2 жыл бұрын
Same in Sweden. This shit looks so dumb😂. I saw another American electrician having real cable inside the wall which also seemed very dumb...
@davidboman7395
@davidboman7395 2 жыл бұрын
A hella lot easier lol
@JG-ej8it
@JG-ej8it 2 жыл бұрын
Me in Norway use hammer on box. Use conduit instead of ridged pipe for routing wire. Every country/state/city has its own codes. Im in tellacom field. Power plant building. Battery cabiets/converter shelves/reverse polarity -48vdc/rectifiers/tower work:antennas and radios for your mobile network. 5g updates. It is alot of work dealing with codes but codes are laid out and changed for safety. Id rather have him wiring my house than "viking with hammer!!!"
@dougking8630
@dougking8630 2 жыл бұрын
??m
@davefoc
@davefoc 2 жыл бұрын
Hi to Norway the birthplace of my paternal great grandparents. FWIW, almost all wiring within a modern American home is done with NMC (Non Metallic Cable) usually known by the trade name Romex. There are various places where NMC isn't allowed or isn't the preferred approach. Wiring in most of those places is usually done with some kind of flex cable that has a flexible metal cover. It sounds like what is done in Norway is at least similar to what is done in the US with regard to this. The conduit used in this video is usually called EMT (Electrical Metal Tube). There are at least two reasons why EMT might be used in the US instead of flex cable. 1. It looks better. Where the conduit is going to be visible and somebody cares about how it looks EMT might be used instead of flexible cable. 2. It provides better protection for the wire. In California where I am from I don't believe EMT is required for use in garages. I also don't think it would have been required in the garage in this video, but it might be in some US jurisdictions. There are some places where rigid conduit is required. This is iron pipe with some kind of bright plating. I think that is required in hospitals.
@Dominick_84
@Dominick_84 2 жыл бұрын
I love the comments of people saying oh you cant do this oh why you do that. If you guys understand anything its that literally every state every country even counties in the same state allow and don’t allow certain ways of doing stuff. So get off his back. He made a good video for those not familiar with the trade. Btw im a licensed electrician so i can speak on the subject. I worked in 4 different states and i can tell you it was all different.
@josephkayrouz3173
@josephkayrouz3173 3 жыл бұрын
In Australia we have not any sort of this😂we just run the wires through the studs and bob is your uncle
@kittsdiy
@kittsdiy 3 жыл бұрын
Same here in Belgium .. wire or flexi conduit :-) This is crazy because no one will ever see it .. sheetrock over it .
@Username-ng8jy
@Username-ng8jy 3 жыл бұрын
We do majority of that in the states. Honestly this is pretty extra. But it’s nice. He won’t have to worry about electrical fore
@kittsdiy
@kittsdiy 3 жыл бұрын
@@Username-ng8jy it's kinda funny how oldschool USA electrical is .. Metal boxes / metal conduit / bending conduit / big bulky switches .. 25 years ago or so we seen this in class bending pvc and metal conduit ..and wirenuts .. last 25 years i NEVER ever used wirenuts / pipe benders :-)
@Deizel23
@Deizel23 3 жыл бұрын
@@kittsdiy Just curious. What do you use? What exposed raceways in commercial buildings?
@soldatheero
@soldatheero 2 жыл бұрын
@@kittsdiy EMT is not the norm anywhere in NA for wood framed houses we just use NMD90 (loomex). Metallic tubing is required on surface level/exposed walls only and usually BX armored cable is used
@toddavis8603
@toddavis8603 2 жыл бұрын
Running pipe inside walls---good job for a crazy restrictive electric code!!
@markchidester6239
@markchidester6239 3 жыл бұрын
I'm building a step stool just like that. Absolutely awesome! Like the saw hook, maybe add a couple other things like holes for screwdrivers and such
@BobClarizio
@BobClarizio 3 жыл бұрын
Yeah! Those are great ideas!
@THEMIDNIGHTCHOPPER
@THEMIDNIGHTCHOPPER Жыл бұрын
I just built a 20x10 shed earlier this year and I want to put in some pipe rather then just run the romex. Never done it, but im gonna use this video for all the basics.
@user-Kdaddy
@user-Kdaddy 3 жыл бұрын
Right to the point. Exactly what I wanted to see.
@Kevinmakesit
@Kevinmakesit 5 ай бұрын
great video, Bob! Lots of tips and no fluff.
@BobClarizio
@BobClarizio 5 ай бұрын
Thanks!
@10p6
@10p6 3 жыл бұрын
Looks very neat. I was going to use metal conduit on my project, but since I needed to run nearly 60 feet of 8/4 plus ground, I cheated and used MC cable. :-)
@w04mach1
@w04mach1 3 жыл бұрын
Awesome Video. 28 years old looking to become an electrician. After working for my father at our families anodizing business, and helping the electrician with odds an ends all the time, this seems like something I would thoroughly enjoy doing. Although I feel weird thinking of switching gears at 28 I also feel it might not be too late, and would significantly improve my mental health. Please share more videos like this. Best tutorial video I have seen so far. Thank You Sir.
@qomco
@qomco 3 жыл бұрын
Honestly, its not too late at all. A lot of young apprentices cant keep it together. If you show up on time and work hard, youre gold to any employer. Add to that places are hiring and paying competitively right now. Its one of the best times to get into a new trade
@cward1954
@cward1954 2 жыл бұрын
At 28, you're more mature than an 18 year old, and at 28, you still have many years ahead of you. Better to switch gears now than to wait until you're 48 or 58.
@Penguin545
@Penguin545 2 жыл бұрын
Left the automotive trade at age 31 after 12 years experience- got a pay raise to do it as a traveling commercial electrician apprentice.
@Dereck1804
@Dereck1804 2 жыл бұрын
I was taught to always pipe in 1 direction meaning, mount a box, run a pipe to wherever the next box is, then mount the next box. It avoids having to fight connectors all the time. It's odd to me seeing it done in the direction you're explaining
@HelloDapp
@HelloDapp Жыл бұрын
it just depends on the person. I do commercial electric, and i'll do it both ways, but i prefer to mount the boxes first, because then i can just take measurements from connector to connector. Sure, you could just measure to the center of the hole on the box, and land it there from the stud, but its more satisfying seeing if i can bend it perfectly to land in the next connector lol
@customsolutions7167
@customsolutions7167 10 ай бұрын
Correct 😂
@danlevesque5437
@danlevesque5437 10 ай бұрын
Then the box instalation might be harder if the pipe is blocking you lining it up or off by a small margin in the hight of the box if the pipe is off a bit 😂
@Deoglas687
@Deoglas687 6 ай бұрын
Hi I am new comer licenced Electrician i try to practice via your video thanks you very much
@BobClarizio
@BobClarizio 3 ай бұрын
That's wonderful to hear! I'm glad my videos are helping you in your practice. Keep up the great work!
@peterohmart5954
@peterohmart5954 3 жыл бұрын
Very nicely done! You stay on topic and show how to do it without giving many examples of how it could be done in so many other places. You gave the "How To" for this application. Thank you! If I had to cut a large hole as you did, I would use a nail plate instead of mounting the conduit to the back of the hole as it could be damaged by a nail from outside. What are your thoughts?
@MrSeth166
@MrSeth166 3 жыл бұрын
The safety plates are required by code in any type of conduit or plumbing, he is just showing how to install EMT in a wood frame since the conduit is required to be at the center of the stud that is why is doing it like that, is just common sense...
@fwbcarl
@fwbcarl Жыл бұрын
Thanks for the refresher. Its been 30 years since I bent pipe. I needed that. Need to make more on conduit bending
@ciranimal
@ciranimal 3 жыл бұрын
Top notch video, Bob! Awesome editing, awesome information and awesome delivery! Keep em comin! 👍🏻
@BobClarizio
@BobClarizio 3 жыл бұрын
Thanks!
@fishypictures
@fishypictures Жыл бұрын
I’m more in line with Dave Nag…..I’ve been an electrician for 40+ years….. in the old days speed was expected…. Now that I’m old I keep it light.. I’m slower than I used to be…. I bid more time for that … I have the best tools …. I now strive to do clean conduit work. The fellas will tear you apart if you don’t, ha ha! Electrical work is fun and I’ve been doing it so long it’s really been good to me. Good money, always in demand , hand arthritis slows me down but I have huge and powerful forearms which is a bonus , that’s from bending pipe, pulling wire and cutting copper. Keep it light guys, take care of yourself…. Your body will break down eventually and that’s a shame.
@randyaivaz3356
@randyaivaz3356 2 жыл бұрын
Good Info, after watching and reading comments, want to add, 7/8" hole in Center of Stud works well as it insures you are more than 1 1/4" from face of stud, then you won't have to use a nail plate. You're strapping accomplished that. Wouldn't remove Insulation from Channellocks. Just put a Pipe Reamer on your Large Screwdriver, or use your Kleins. If running a Lot of Conduit, use a Set Screw Screwdriver, won't slip off, faster. I live in The Keys, Corrosion and Rust is a problem, Smurf(ENT) Is common. For a Shed not planning on any Expansion or Additions, would use MC or Romex. Can't pull additional circuits, switch legs or whatever. We have to Pull a Ground Wire in EVERY Conduit, even Metal. You could also show temporarily removing box to allow conduit to enter connector without fighting it. If you can get to this shed before siding and door frame installed, you may be able to use straight pipes, eleminate the 2 90's, less pipe less wire? In Comments, I see People mention a Band Saw for cutting Conduit, seems like putting in a Thumbtack with a Sledge Hammer. Found for me a Milwaukee Hackzall to work well. M12 is good enough, M18 is heavier, but more Capacity. If Accurate height is Important(Kitchen Counter and Bath)where tile will show the're off, I will use a Pencil. A Razor knife will leave a more precise mark. I would also subtract 5" and put 1 mark on pipe. The second mark may be used accidently.
@mgiaco52
@mgiaco52 3 жыл бұрын
Old RACO number 1900 box (4" sq metal box) I have been an electrician since the late 60's and i was taught that all 4'' box were 1900. As for the EMT many states and towns require it in wood construction.
@tysonjohnson514
@tysonjohnson514 2 жыл бұрын
Dude that’s pretty awesome. I recently just got into bending conduit and am having a fun time with the creativity it gives me
@godmadesam
@godmadesam 2 жыл бұрын
When I went through the union apprenticeship they always taught us to use pencils ✏️ to mark our pipe. This is a good habit to keep just in case your pipe is exposed. We use reamers (proper tool) and levels.
@sonofnumenor6683
@sonofnumenor6683 2 жыл бұрын
Agreed.sharpie on exposed pipe looks ugly and unprofessional.
@duanchamp1988
@duanchamp1988 2 жыл бұрын
IT DEPENDS ON THE JOB....THATS ALL...I USE A SHARPIE FOR PIPE, WATER OFF MARKERS FOR PAINT(DELICATES).
@customsolutions7167
@customsolutions7167 10 ай бұрын
Sharpie is fine .. Exposed pipe already looks ugly ...😂😂
@JohnThomas-lq5qp
@JohnThomas-lq5qp Жыл бұрын
Retired sparky here . Think it's called a 1900 box is because it has 19 cubic inches. Called 4 & 11/16" boxes 2100 boxes. Only used 2 & 2/8" boxes to give you more room for wires or deep devices. Great example is a duplex receptacle with two charging ports. Almost need a shoe horn & a rubber mallet to get it into box.
@MrWaalkman
@MrWaalkman 2 жыл бұрын
Nice work on showing the basics. Kind of left that interior corner as the elephant in the room though. Would be nice to see the Chicago approved method to getting from one wall to another. We used short radius benders for interior 90's in Colorado Springs. The AHJ would allow it as long as you didn't exceed one shorty per run.
@jamesfox8930
@jamesfox8930 2 жыл бұрын
I can only imagine the monstrosity of 1/2" emt through a 2 stud corner. ouch.
@chrisstovall7329
@chrisstovall7329 Жыл бұрын
In my experience, you typically go up into the ceiling and then back down to get from wall to wall most efficiently, but everyone has their preferred way of course.
@MrWaalkman
@MrWaalkman Жыл бұрын
@@jamesfox8930 sorry that I didn't see this earlier, but yeah, it wasn't pretty.
@abdushukursadinov4765
@abdushukursadinov4765 Жыл бұрын
Салом из Узбекистана Удачи вам мне очень понравилось ваше подход к работе 👍👍👍
@WoodsmokeSelf-Reliance
@WoodsmokeSelf-Reliance 2 жыл бұрын
Some cities and counties in the U.S. require rigid EMT (Electrical Metal Conduit) in situations where the wall cavities are exposed. Wiring needs to be protected from abrasions, or as some people do, hanging objects on the wire. In basements especially, I have seen everything from clothes hangers, to tools hanging from the Romex/Non-Metallic Cable (NMC) in the joist bays. This is very dangerous! So rigid conduit is used to protect against the wire being damaged and causing a short. Some jurisdictions allow flex conduit, but only in cases where the flex will be hidden behind a finished wall. Flex is more durable than Romex, but much easier to run than rigid conduit and then having to pull wire.
@jacobhess3n327
@jacobhess3n327 2 жыл бұрын
Rigid and emt are both different types of conduit
@offgridsystems1166
@offgridsystems1166 2 жыл бұрын
Regular emt not rigid you handyman you. And flex is limited at 6 feet you silly silly man
@jacobhess3n327
@jacobhess3n327 2 жыл бұрын
@@offgridsystems1166 😂😂
@carlosjortiz4677
@carlosjortiz4677 2 жыл бұрын
Good video. I have to get ready. My garage is next.
@williameisenberg1999
@williameisenberg1999 3 жыл бұрын
Tough town to require emt compared to a Mc cable … or a uf cable ….
@krakenwoodfloorservicemcma5975
@krakenwoodfloorservicemcma5975 3 жыл бұрын
I agree. It’s absolutely retarded.
@jburnes41
@jburnes41 3 жыл бұрын
@@krakenwoodfloorservicemcma5975 when you think about an electrician coming behind you to trouble shoot you will thank god for the pipe. i live in the northshore of chicago would not have it any other way. it might take a little more time, but so much easier to work with. and the fact that if to do have a problem much easier to trace and repair.
@krakenwoodfloorservicemcma5975
@krakenwoodfloorservicemcma5975 3 жыл бұрын
Whatever. Troubleshoot? Seriously? Chicago sucks, EMT sucks, residential work sucks as well. Your little league team that got caught cheating sucks the most.
@HenriBeaudoin
@HenriBeaudoin 3 жыл бұрын
@@krakenwoodfloorservicemcma5975 Thank god for NM :) Literally fuck running Metallic and EMT in Resi.
@krakenwoodfloorservicemcma5975
@krakenwoodfloorservicemcma5975 3 жыл бұрын
I love bending pipe, but if you are going to do it, at least make it all surface mount.
@ImperialPainting-ht8ql
@ImperialPainting-ht8ql 10 ай бұрын
Bruh 💯 About to do a project where I may need to run conduit. This came in clutch Thanks fro the great tutorial
@sh115067
@sh115067 2 жыл бұрын
So crazy some places require pipe inside houses. That would take forever to rough in a house. In Canada we run Loomex
@57energon
@57energon 2 жыл бұрын
Never mind missing the part about bonding in the code. My question is why use all the 4 squares. Now you have to use a pile of plaster rings to finish the rough in. You will have wall full of steel. It is so hard to watch him use channel locks like that. Use a reamer because he's not checking the inner surface. That is an apprentice move. Hope you don't mind chasing short circuits.
@JohnThomas-lq5qp
@JohnThomas-lq5qp Жыл бұрын
Stopped using Channelocks to deburr EMT 40 years ago when Klien came out with a deburrer ( for 1/2 to 2" EMT ) that locked into a screwdriver then maybe 30 years ago Klien finally came out with their own deburrer mounted to a screwdriver.
@monteglover4133
@monteglover4133 3 жыл бұрын
Conduit far and above the best way to wire a house!
@Dezeberbro
@Dezeberbro 3 жыл бұрын
Definitely the safest
@todshawcross2972
@todshawcross2972 3 жыл бұрын
Only if you run a ground wire
@jburnes41
@jburnes41 3 жыл бұрын
@@todshawcross2972 you do not need a ground in metal conduit lol. only on some circuits.
@todshawcross2972
@todshawcross2972 3 жыл бұрын
He said the safest it's only safe if there's a ground wire loose lock nuts loose set screws no ground screw at junction boxes. Like I said only safe if there's a ground wire
@jburnes41
@jburnes41 3 жыл бұрын
@@todshawcross2972 there should never and i mean never be a loose lock nut. this is one of the first thing an inspector looks for. thats the fastest way of starting a house fire. thats what they make channel locks for. it is our job as electricians to makes sure every locknut is tight. every pipe is strapped. you would get fired where i worked if you did sloppy workmanship. every pipe must be level. it must look like someone who knew what they were doing did the job. i remember doing a 40 meter service. and the inspector came in to inspect. he took one look at the job we had done. and said you passed. he saw the workmanship. and that is the most important thing. to make it look like you know what you are doing period.
@nathanmciver6496
@nathanmciver6496 Жыл бұрын
"How to" is not yellow! Real safety is being being able to help one another! Way safer for somone to watch your video than get scared of fear sales with safety! KZbin saves alot of grief! :) Happy building
@anthonyhitchings1051
@anthonyhitchings1051 3 жыл бұрын
putting conduit inside wood framing is nuts, it belongs in commercial and industrial applications.
@jarrydee2799
@jarrydee2799 3 жыл бұрын
In chicago you have to use conduit in residential. I think new york to. It's because of the rodents eating the wires. Would be such a pain in the ass
@rogerdodger3209
@rogerdodger3209 3 жыл бұрын
@@jarrydee2799 not nyc , armored bx cable , in nassau / suffulk / westchester romex is allowed , olrder homes will have bx. conduit is commercial or surface on interior block or brick , exterior is in rigid pipe
@user-jh1mq2ih2u
@user-jh1mq2ih2u 3 жыл бұрын
When you think you know it all and you don’t .. stay in your lane
@user-jh1mq2ih2u
@user-jh1mq2ih2u 3 жыл бұрын
@@rogerdodger3209 armored box cable is still the same concept as using conduit except no pipe benders needed…
@rogerdodger3209
@rogerdodger3209 3 жыл бұрын
@@user-jh1mq2ih2u wtf are you even talking about ? stfu noone is saying its a different concept , learn to read , someone said they think you need to use conduit in residential , and you dont. holy shit with the keyboard tough guy act.
@cybernatwa
@cybernatwa 11 ай бұрын
Wow, that is so different. I see your plain-screw adaptor and coupling has a pinch screw on it unlike here is PVC without the pinch screw. Working with steel - ends are threaded for lockrings/locknuts, couplings, etc. while flexible conduit (Anaconda) has a gland to secure it.
@jarrydee2799
@jarrydee2799 3 жыл бұрын
It's a 4 square box in michigan, not 1900
@robertoparra9969
@robertoparra9969 3 жыл бұрын
4 square bracket box here i SoCal. i dont think ive seen the number 1900 on them either.
@mwolf5469
@mwolf5469 3 жыл бұрын
@@robertoparra9969 I think it's an old 1970 RACO number yes I'm old.
@Victoria-kx3jh
@Victoria-kx3jh 8 ай бұрын
Wow thank you very much! Just starting out lvl 1 construction electrician so exciting
@trevorritchie2575
@trevorritchie2575 2 жыл бұрын
Slotted screws...ugh...so glad I live in Canada. Americans should try Robertson square drive screws. They're much better because they hold onto the screwdriver and don't slip off!
@mattsabeast5
@mattsabeast5 2 жыл бұрын
Lol you suck square drives take Philips head and no decent modern products only have a flat head drive if they require any amount of force be applied. You think your smart but just don't understand manufacturing or construction.
@mattsabeast5
@mattsabeast5 2 жыл бұрын
Also KZbin won't let me call you bad words for a Canadian but I very much dislike your arrogance. Anything you have in Canada is the same as USA, your like our little sister we look out for.
@VashtheReapr
@VashtheReapr 2 жыл бұрын
Slotted should have been fazed out they are 🗑
@ArkamasRoss
@ArkamasRoss 11 ай бұрын
We use Robertson quite a bit in electrical actually. Not sure why he’s choosing to use a slotted driver on the couplings when they have Robertson inserts but to each his own. Milwaukee even makes a nice reaming bit with a bit holder for impact drivers. Could be saving himself some time.
@TeslaBoy123
@TeslaBoy123 2 жыл бұрын
That is a real electrical work using metal conduit only real trademans know how bend conduit 👍
@seanoneill1010
@seanoneill1010 3 жыл бұрын
First year Electrical apprentice here. i was told that they are called 1900 and 411 boxes because that was their original part number. Dont know if thats exactly true but would love some knowledge if anyone has it!
@hiramsoriano40
@hiramsoriano40 2 жыл бұрын
The box size that he is using is called 4-square bracket boxes, the ones he is using are shallow and there are also deep boxes. 411 refers to a box that is bigger in size and it also comes in a deeper version.
@Homeinspectorsny
@Homeinspectorsny 2 жыл бұрын
19900 box 19 cubic inches, non deep version 411 box because of its dimensions 4 and 11 16th
@jasonjarden1237
@jasonjarden1237 2 жыл бұрын
Anthony is correct. I work for a supplier. I was told by an electrician when i first started that a 1900 is a 4sq 1-1/2 deep box. Because they are 19cu Inches. Now most people call all 4 square boxes 1900’s but the most popular is the 4sq 2-1/8 deep. 411 boxes are 4-11/16 x 4-11/16
@adamsharp201
@adamsharp201 Жыл бұрын
Concentrate on getting your qualifications before commenting on electrical work pal. Good luck with your apprenticeship
@lotuselise4432
@lotuselise4432 2 жыл бұрын
I was a scrawny 20 something back in the day installing conduit on building sites, 20, 25 and 32mm which is 1.25 inch using a Hillmore bender, on some sites which where hazardous sites ie fuel dumps in the aviation industry the threads had to be double length none of these joints that you are using, the pipe had to be threaded. I am pleased to say that I was a master on conduit, tray and trucking work as well as building risers and installing switchgear (I was Industrial not Domestic) but I took Pyro to another level, 6ft tails on 7 core was a challenge and still have the tools.
@gerdberg4188
@gerdberg4188 3 жыл бұрын
How about a reaming tool
@Faggledickbob
@Faggledickbob 3 жыл бұрын
Channels work fine if you don't have a reamer. So do linesman, dikes, etc
@gerdberg4188
@gerdberg4188 3 жыл бұрын
If you only have a few to do yeah…. I’m not going to waste the time if i am doing a pipe job . And for small pipe I carry 6 inch channelocks . Fewer tools you have to pouch for certain jobs improves efficiency . Never carry what you don't need too ….
@alelaranpl485
@alelaranpl485 2 жыл бұрын
Thanks, Bob. It was good quick introduction, how to install metal conduits.
@ericlesperance9362
@ericlesperance9362 2 жыл бұрын
That was a sweet 85 degree bend with his wrestling work boots. Haha
@paulflores7292
@paulflores7292 3 жыл бұрын
Good work bro simple and straightforward I live in L.A. so im going to do this around the outside of the house for so lightingon my driveway
@jakesully5402
@jakesully5402 3 жыл бұрын
Not sure about LA, but where I am from you can not use EMT when exposed to moisture. You may need to consider using PVC or rigid conduit. Both of those conduits can be exposed to moisture.
@christiancassini768
@christiancassini768 3 жыл бұрын
Use compression couplings.
@Mike45-47Q
@Mike45-47Q 3 жыл бұрын
For the love of God....do not do that.
@strangerofthe2067
@strangerofthe2067 3 жыл бұрын
If you bury it don’t forget to drill drain holes into the pipe so it doesn’t fill with water… 😂
@davids7209
@davids7209 3 жыл бұрын
As an electrician, I think he should have spent more time on the fundamentals of using an EMT bender. There's so many things you can do with it. Learning to use the bender correctly can save not only time but money. Using the star vs the arrow when creating offsets, saddles. and other bends in addition to 90's are an electricians bread and butter. Additionally, the NEC (national Electrical Code) requires that vertical runs need to be strapped down every 3' and while the vertical run you showed was under 3' (barely) I would have still ran the pipe against the stud and put a strap half way up the run which would have required a box offset at the higher box.
@josharmstrong6529
@josharmstrong6529 3 жыл бұрын
Also "stovepiping" the horizontal. I mean If I saw this I would eye roll an laugh. If he was an employee of mine, he's doing it again the right way. This is first year apprentice work IMO. Reducing fittings is always the way to go, less spots for hang ups, looks nicer, you look like you know what you are doing, and costs less. On a video labeled "How to bend and install electrical conduit" this would be a "how not to" for my apprentices.
@Dynamice1337
@Dynamice1337 3 жыл бұрын
Vertical runs need to be strapped every 3'? Vertical runs are the same as any other run, 3 feet from every termination (box) and every 10 feet after that. A caddy CS812D would work perfectly there.
@davids7209
@davids7209 3 жыл бұрын
@@Dynamice1337 Well it's clear I was referring to "from box to box" but assholes gotta be assholes I guess!
@robm3063
@robm3063 2 жыл бұрын
Got to tell you I piped hundreds of houses in the west, north west, south west suburbs of Chicago from 98 to the bubble burst 2008. All union work in DuPage, Kane, Will, McHenrey ,Kendell, counties. Never once did we have to brace the pipe coming out of a outlet or switch except at the top. Horizontal runs were nail strapped so pipe did not move and make noise. Len the inspector for Lombard was as tuff as they come and never once did he fail vert pipes. Now a horizontal pipe moving yes or forgotten set screw. He even taught code class for people wanting to be inspectors. I guess everything is local, are way is different then other places. Remember people the code is there but it's all what the town or jurisdiction wants.
@robm3063
@robm3063 2 жыл бұрын
sorry not 98 but 1988
@themoneygame5121
@themoneygame5121 Жыл бұрын
Wow it's so easy!! I'm going to buy everything you have wire install all the pipe!!!
@jeffhobart7484
@jeffhobart7484 2 жыл бұрын
You got it done and everything looked fairly level, but I was having anxiety the whole time. Man you really need to get yourself a reamer. Dump all the tools that you don’t need too. I’ve seen apprentices work faster and more efficiently that that. I mean I guess what you showed didn’t look that bad, but man you gotta think things through before you start. I know I’m being a bit critical, but watching someone else run conduit (not “pipe” like you kept saying) is difficult to do. I hope everything looked good when you were finished.
@jeffhobart7484
@jeffhobart7484 2 жыл бұрын
I’d recommend using a portaband too. Quick and easy. You should have boots on as well. I’d ditch the marker too because it looks terrible. Especially when you were making two marks for your 90’s since you couldn’t subtract 5 in your head. Im glad you didn’t try to bend an offset, or even a saddle, because I may have lost my mind.
@tjo1984
@tjo1984 Жыл бұрын
Great video, man. Thanks very much. You're a natural teacher. All best.
@theprofessorfate6184
@theprofessorfate6184 2 жыл бұрын
Christ, talk about overkill. In the old days, they used GRC 40 , as EMT hadn't been invented yet. Complete waste of resources(metal) and time. Chicago must have some really ridiculous building codes.
@brandonhoffman8780
@brandonhoffman8780 2 жыл бұрын
I’m an electrician in Florida and I had no idea you can’t use romex in Illinois I just found this out from this video
@SeanLeonDrumz
@SeanLeonDrumz 3 жыл бұрын
358.30(A) EMT shall be securely fastened within (3 ft) of each outlet box, junction box, device box, cabinet, conduit body, or other tubing termination. Since you didnt make any box offsets this is not to code correct?
@dsingh4512
@dsingh4512 3 жыл бұрын
I don’t see how box offsets are required to securely fasten the tubing. He did secure the EMT using nail straps at 19:07 and that was within 3 ft of the box.
@ThreePhase470
@ThreePhase470 3 жыл бұрын
@@dsingh4512 yep i agree. using those pipe straps would be an approved method of strapping as long as he's within 3 ft
@thomasmarable6818
@thomasmarable6818 3 жыл бұрын
There are straps you can use without box offsets. I only use box offsets for exposed work, never in walls
@SeanLeonDrumz
@SeanLeonDrumz 3 жыл бұрын
@@thomasmarable6818 interesting! Thanks for that tip.
@jonxiong5439
@jonxiong5439 3 жыл бұрын
@@dsingh4512 should the short conduit be strapped? it is more than 3ft long? he did say vertical distance is 33 1/4'' plus 9 1/2'' equal 42 3/4''.
@bobstaurovsky3506
@bobstaurovsky3506 Жыл бұрын
Did a recording studio years ago, drilled from the outside on all walls long EMT was sent through, end of job, wood dolls were put in outside holes !!!
@partyhardmonks
@partyhardmonks 2 жыл бұрын
Don't know about you guys but this wouldn't fly where I'm from. The pipe going up has no straps.
@OriginalMerk1904
@OriginalMerk1904 2 жыл бұрын
It wouldn't go any place. The jnstall isn't up to code. The NEC is "national" electrical code. Unless this isn't in America.
@nevinkuser9892
@nevinkuser9892 Жыл бұрын
​@@OriginalMerk1904it's Ontario Canada.
@OriginalMerk1904
@OriginalMerk1904 Жыл бұрын
@@nevinkuser9892 i stand corrected.
@brendanhull3687
@brendanhull3687 2 жыл бұрын
as a plumber just a little FYI, the bit this guy is using to drill his holes is REALLY good for wood, but if you hit just ONE nail with it that bit is GONE. lol. USe hole saws guys
@--JohnDoe
@--JohnDoe 3 жыл бұрын
Use a level or two if on unlevel surfaces, to make sure your 90 is a 90. Emt needs to be supported 36" from terminaton points/the box
@vlad1889
@vlad1889 3 жыл бұрын
At least every 10ft there after and no more than 360degree of bands between junction boxes.
@jarrydee2799
@jarrydee2799 3 жыл бұрын
@@vlad1889 That's because it would be a bitch pulling wire through 360 bends without a pull box.
@notnecessary7730
@notnecessary7730 3 жыл бұрын
Vertical studs count as support, ya don't need those stupid anchors, well, unless it's a local code, besides that who the heck runs conduit horizontally Through studs??? If that is local code, the ahj is a frigin moron
@Dynamice1337
@Dynamice1337 3 жыл бұрын
If you used a level on work that was behind drywall on my job you wouldn't last long. Ain't no one got time for that.
@jburnes41
@jburnes41 3 жыл бұрын
@@notnecessary7730 i do. its call saving on material. less wire less pipe less time. plus you can get away with a stub bend or as i would do it run straight from box to box. and with the cost of wire. why would you run everything up and down. whats the fastest way from point a to point b, a straight line. i was taught by a master. the short cuts. the object is to make it code but keep it simple. and that time is money.
@cylentship1532
@cylentship1532 10 ай бұрын
This was super informative and helpful! thanks for sharing all the detail on your tool tricks and workflow! I just moved into an industrial loft and we have exposed conduit on exposed brick and there are mostly enough outlets on the main floor but NONE up the steps into our platform bedroom area. Would love to see you do a video on how to pick up from the ending outlet box and add a few more all the way to the wiring and connection phase=) Thanks!
@HaroutBlack
@HaroutBlack 10 ай бұрын
Jesus is the only way to healing, restoration and salvation to all souls. Please turn to him and he will change your life, depression into delight, soul heading from hell to heaven all because of what he did on the cross “Whoever calls upon the name of the Lord shall be saved” Romans 10:13
How to bend Electrical Conduit Pipe
22:06
Bob Clarizio
Рет қаралды 85 М.
拉了好大一坨#斗罗大陆#唐三小舞#小丑
00:11
超凡蜘蛛
Рет қаралды 14 МЛН
Oh No! My Doll Fell In The Dirt🤧💩
00:17
ToolTastic
Рет қаралды 11 МЛН
Sub Panels Explained - Why are neutral and ground separated?
16:22
The Engineering Mindset
Рет қаралды 1,3 МЛН
Bending Conduit Part 1 of 5 (Polly Friendshuh)
12:55
Dunwoody College
Рет қаралды 990 М.
Wire Pulling - The Basics
6:44
Southwest Industrial Electric
Рет қаралды 209 М.
How to Bend an Offset in Conduit
10:01
Electrician U
Рет қаралды 235 М.
Electrical Wiring Basics
23:40
BrettleyBuilt
Рет қаралды 2,8 МЛН
IDEAL National Championship Pro 2nd Round Parallel EMT Bends
33:57
Sparky Channel
Рет қаралды 540 М.
COMMERCIAL ELECTRICAL MATERIALS Apprentice Electricians Should Know
14:37
Why Romex Doesn't Belong in Conduit: Quality and Longevity
6:20
abrelectric
Рет қаралды 62 М.