Electrical Designing of High Rise Building G+10 | Electrical Design Course

  Рет қаралды 66,626

Electrical Infinity

Electrical Infinity

3 жыл бұрын

Hey guys! Welcome back to the new video of electrical infinity.
In this video, I attempt to explain the electrical design of high rise building G plus 10
It consists of 5 steps
1. Calculation of total connected load
2. Transformer sizing
3. Circuit breaker selection for transformer
4. Circuit breaker selection for main meter panel and flat load
5. Drawing of Single Line Diagram
Thanks For Watching
Electrical Infinity
Like and Subscribe!

Пікірлер: 143
@prasenjit_hazra
@prasenjit_hazra 2 жыл бұрын
A Big Thanks for your magnificent job of teaching us from scrach. It often helpful to make some quality negotiation with consultant & infra individual as a "Sales Specialist".
@ElectricalInfinity
@ElectricalInfinity Жыл бұрын
Thank you too!
@user-yz5bw4dm2d
@user-yz5bw4dm2d 9 ай бұрын
A very rare video on electrical design. Thank you so much for the clarity in explaining.
@ElectricalInfinity
@ElectricalInfinity 9 ай бұрын
You are welcome. Make sure you subscribe and share it with your friend's and colleagues. Thanks ❤️
@incredibleindia3572
@incredibleindia3572 10 ай бұрын
Wonderful Explanation ❤
@rajeevneela2861
@rajeevneela2861 8 ай бұрын
Thank you... good knowledge given
@saalimbaig4896
@saalimbaig4896 Жыл бұрын
Very useful information
@imrankhan-uf7ww
@imrankhan-uf7ww 2 жыл бұрын
great work sir ❤️❤️❤️❤️
@smnmj3320
@smnmj3320 Ай бұрын
Thanks brother..it's a very helpful video.❤
@ElectricalInfinity
@ElectricalInfinity Ай бұрын
Most welcome
@salunkhesandeep
@salunkhesandeep Жыл бұрын
Very well explained... Thanks so much for sharing knowledge....
@ElectricalInfinity
@ElectricalInfinity Жыл бұрын
Always welcome 🙂
@sultanurrahman799
@sultanurrahman799 Жыл бұрын
It's helpful for technical support
@sefatullah441
@sefatullah441 2 жыл бұрын
manny many thanks sir g....outstanding video.......please continue thils topic electrical designing. upload more videos related to electrical building design..l...cable selection farmula etc.etc please
@abdiit5129
@abdiit5129 3 жыл бұрын
Great, thank you! Can we consider socket outlet power consumtion as a common connected load? And also please share us electrical design for residential house G+3 with all connected load like kitchen, lighting, washing machine, Iron, sockets, water pumps, oven , etc. Thanks bro.
@saleembasha7924
@saleembasha7924 5 ай бұрын
Thank you for the detailed video bro.,👌👌👌👍👍👍
@ElectricalInfinity
@ElectricalInfinity 5 ай бұрын
Thanks Saleem 😊
@yatinthakuryt3362
@yatinthakuryt3362 3 ай бұрын
Thank you very much for giving such great information.
@ElectricalInfinity
@ElectricalInfinity 3 ай бұрын
You're welcome
@salahuddinbangash4785
@salahuddinbangash4785 Жыл бұрын
Damn Nice bro, I thought it will be difficult but this is just basic electrical engineering 🔥🔥
@ElectricalInfinity
@ElectricalInfinity Жыл бұрын
Yeah much easier than engineering theories. But on Job it is a challenge to deal with complexity of projects. This was just a basic sample to make it easier for audience to understand.
@etelanarendra9873
@etelanarendra9873 8 ай бұрын
Excellent
@gkd5421
@gkd5421 2 жыл бұрын
Sir, all your vedios are very informative..I seen all your channel... waiting for next latest vedios... thank you very much...
@ElectricalInfinity
@ElectricalInfinity Жыл бұрын
Keep watching
@Bandarofficial
@Bandarofficial Жыл бұрын
Thanks you so much.
@Saichanti77
@Saichanti77 10 ай бұрын
Thanks ❤
@spritor6463
@spritor6463 2 жыл бұрын
Good to see you upload regularly again :)
@ElectricalInfinity
@ElectricalInfinity 2 жыл бұрын
Thanks 😎📽
@therealitypresenters8616
@therealitypresenters8616 2 ай бұрын
Great, haven't found any video on any platform like this. Glad if add cable sizing calculation grounding and lightning protection system.
@ElectricalInfinity
@ElectricalInfinity Ай бұрын
Glad it was helpful!
@rahulgaikwad8430
@rahulgaikwad8430 Жыл бұрын
very good Explanation
@ElectricalInfinity
@ElectricalInfinity Жыл бұрын
Thanks for liking. Keep watching!
@yograjsingh3604
@yograjsingh3604 4 ай бұрын
wow very helpfull
@mdshadaabalam2612
@mdshadaabalam2612 2 жыл бұрын
Awesome explained.....sir kindly make video on cable sizing, voltage drop, ssc, bus bar sizing, earthing and lighting arrester calculation for the same project.
@mdshadaabalam2612
@mdshadaabalam2612 2 жыл бұрын
Request you to make video as soon as possible.
@mobilesandcomputers5931
@mobilesandcomputers5931 2 жыл бұрын
I am working as a deputy messenger in a good housing society in Pakistan. I have seen your video on youtube. It is important to learn building. Tell me some main points
@sagarvv4699
@sagarvv4699 2 жыл бұрын
Thank you so much for this. Could you please if you have time just explain the above 40-floors building details as per Indian standard.
@PraveenKumar-rh9bv
@PraveenKumar-rh9bv 3 ай бұрын
Awesome very useful
@ElectricalInfinity
@ElectricalInfinity Ай бұрын
Thanks a lot
@rashidchibvuri2036
@rashidchibvuri2036 6 ай бұрын
Thank you so much sir
@ElectricalInfinity
@ElectricalInfinity 6 ай бұрын
Welcome 🙂
@koala4599
@koala4599 Жыл бұрын
first of all thank you for the great video, But please can you explain how you decide to use 7.5 kw for 3BHK ?
@md.gufranansari9672
@md.gufranansari9672 3 жыл бұрын
Please make a video overall design parts such as cable calculation, voltage drop, short circuit, power factor.
@shahbaazalam1003
@shahbaazalam1003 3 жыл бұрын
Can you please make a video on calculation of lightning arrestor and calculation of earthing rod, pits and wire?
@engmohamedmuraase5119
@engmohamedmuraase5119 2 жыл бұрын
thanks sir for your kind to explain us more I would like to ask you PART-4 for the C.B sizing for main meter panel and flats.at PANEL-1 How you got common load result in 60kw? thanks sir.
@davendertaneja3489
@davendertaneja3489 3 жыл бұрын
Nice 👍
@ElectricalInfinity
@ElectricalInfinity 3 жыл бұрын
Thanks 😊
@shahbaazalam1003
@shahbaazalam1003 2 жыл бұрын
Can you make a video on the cable size selection from transformer to transformer's CB and from tx's CB to load' CB?
@sandeshdhungana2749
@sandeshdhungana2749 2 жыл бұрын
Great video, thank you!! Would you make video on cable sizing considering voltage drop for high rise building.
@ElectricalInfinity
@ElectricalInfinity 2 жыл бұрын
Thanks. Will make it soon.
@jahanzaibilyas2649
@jahanzaibilyas2649 2 жыл бұрын
I think common load should be seperated and it should have Seperate SMDB
@emr207
@emr207 6 ай бұрын
🎉super
@ElectricalInfinity
@ElectricalInfinity 6 ай бұрын
Thanks 😊
@dineshmehta3688
@dineshmehta3688 Жыл бұрын
V good
@franchettecariaga
@franchettecariaga Жыл бұрын
Hello! I just saw your channel and I am so thrilled. J would just like to ask.. Is this as per australian standard?
@ElectricalInfinity
@ElectricalInfinity Жыл бұрын
Hi Franchette 👋, Thanks for watching. Yes, the design is as per Australian standards.
@mithunmathew7965
@mithunmathew7965 2 жыл бұрын
Sir, We need to consider hvac load for public area and corridor's, Firepump
@_InzimamImtiazuddin
@_InzimamImtiazuddin 3 ай бұрын
Thank you very much for this informative video. I had one question. 2BHK flats are provided with single phase supply. So when determining C.B size, for converting Watts to Amps, we should be multiplying with 8 and not 1.9 right? (Based on your G+5 electrical design video)
@sefatullah441
@sefatullah441 2 жыл бұрын
waiting for your next video.. please upload soon
@ElectricalInfinity
@ElectricalInfinity 2 жыл бұрын
Soon
@AkashSingh-jz4zo
@AkashSingh-jz4zo 2 жыл бұрын
In the video, df for residential is mentioned as 0.6, but you considered 0.75, why the difference? And what are the actual standards?
@sabinaktar5135
@sabinaktar5135 Жыл бұрын
fab❤
@ElectricalInfinity
@ElectricalInfinity Жыл бұрын
Thanks
@Belive_trust_wait
@Belive_trust_wait 7 күн бұрын
Sir give a link for , workout screen calculation...give a new video also sir
@roofi881
@roofi881 2 жыл бұрын
HI Dear, I wanted to know that why did you assume DF as 70% while for the commercial buildings you mentioned earlier standar DF is 80-90% in India. please explain this point, Thanks
@sangularnamibe8572
@sangularnamibe8572 2 жыл бұрын
was it 80-90% or 60-90%? I may be wrong.
@kv848
@kv848 3 жыл бұрын
Great brother..Suppose you have 2 transfer pumps,1 is standby and other is on duty, means they will work interchangeable and both will not ON at Sam time and they are in same panel MCC,..So how will you calculate main cable to this panel, will you consider kW of both motor or only 1 ?
@ElectricalInfinity
@ElectricalInfinity 3 жыл бұрын
Total of both.
@kv848
@kv848 3 жыл бұрын
@@ElectricalInfinity but at any instant, both will not work together, then why we consider both load ? Is it general rule to consider both ?
@ElectricalInfinity
@ElectricalInfinity 3 жыл бұрын
That's why we take 0.7 demand factor after calculating total load.
@ZubairAhmed-uc7tb
@ZubairAhmed-uc7tb 10 ай бұрын
Thanks for the Video, Can your please explain how the Multipier Value (KW - A =x1.9 ) Comes. Where as I =P/(VxPF) for Single phase and I = P/(1.732xVXPF). Kindly Correct me if I am Doing any mistake understanding Data manipulation. Warm Regards
@Premkumark90
@Premkumark90 2 жыл бұрын
Hello, Can I convert kw to amps by . First kw to kva Then kva to amps. If do like this different values coming ,what should I do?
@arunkumarthakur9679
@arunkumarthakur9679 2 жыл бұрын
B+P+33 including club, stp, water supply, fire system. Provide electrical load calculation.
@altamashsayed5264
@altamashsayed5264 11 ай бұрын
I have a doubt related cb sizizing For 1500kva transformer Secondary side. Once we convert kva to amp 1500kva*1.4 =2100A Should be consider 1.5 safety factor or directly select breaker from 2100A
@demonkiller2358
@demonkiller2358 3 жыл бұрын
Can u make video on Important is and nec standards
@ElectricalInfinity
@ElectricalInfinity 3 жыл бұрын
Will try to make one
@copycatonlyoriginal6585
@copycatonlyoriginal6585 Жыл бұрын
Could you please provide links to reference guidelines?
@seng7333
@seng7333 Жыл бұрын
Nice explanation But The breaker size of 40A for 5kw load seems to be high Also 50A breaker is not standard size
@habibullah7853
@habibullah7853 5 ай бұрын
This is very informative. I am here in UAE as a fresh electrical engineer and looking for job. Can anybody help me getting a job. Thank You
@eaknadhwilson5931
@eaknadhwilson5931 Жыл бұрын
Bro it's better to share the image of those calculations thanks 👍🏻 very useful
@ElectricalInfinity
@ElectricalInfinity Жыл бұрын
Noted
@kobe8502
@kobe8502 Ай бұрын
At 11:00 how did you get those MCCB values? Why is it almost doubled when you already multiplied them by 2?
@anandsatsangi1071
@anandsatsangi1071 Ай бұрын
Safety factor
@Concepttalks98
@Concepttalks98 2 жыл бұрын
Brother you didn't count future expansion of 20-30% why? Also you considered only demand factor but not diversity factor .. And i designed further and calculated and i got secondary current more than 1200A ...so should I take 3 runs of 1core 300sq mm cable or 3 run of 3 core 300sqmm cable.?
@mujeebrehman7097
@mujeebrehman7097 Жыл бұрын
How you find the value of 1.4 when you convert kva to amp ?
@sachinlandge6401
@sachinlandge6401 Жыл бұрын
How to calculate electrical meter room and duct size
@everythingforyouonly5694
@everythingforyouonly5694 2 жыл бұрын
Why you take 2 time demand factor 1) for TCL and 2) for metering panel c.b selection
@everythingforyouonly5694
@everythingforyouonly5694 2 жыл бұрын
Please give the answer ?
@kalingahistory
@kalingahistory 11 ай бұрын
But the loads you clubbed together are single-phase loads. Where as the main power supply will in three phases.
@sefatullah441
@sefatullah441 2 жыл бұрын
please make your next video at low speed
@digantpatankar3758
@digantpatankar3758 2 жыл бұрын
Sir please mention cable size.....in SLD...
@ElectricalInfinity
@ElectricalInfinity 2 жыл бұрын
Will do separate video for that
@AK_Entertainment26
@AK_Entertainment26 Жыл бұрын
please upload video we are waiting for new video
@muhammadwaqas4699
@muhammadwaqas4699 Жыл бұрын
Circuit breaker calculations?
@altamashsayed5264
@altamashsayed5264 2 жыл бұрын
I need urgent help. Actually I got bit confused. I have to select cable, which load I should consider while selecting cable size from transformer to MDB Should it be tcl amp or peak load amp or transformer amp or circuit breaker amp. Pls do reply as early as possible
@ElectricalInfinity
@ElectricalInfinity 2 жыл бұрын
Usually a cable between transformer and supply connection facility is provided by supply authority and is sized depending on transformer secondary side ampere setting. Supply connection facility is used by supply authority to set the current to certain required amperes depending on supply application done by electrical consultant by calculating max demand. The cable from supply connection facility is sized depending on circuit breaker setting in supply connection facility. I hope this answers your question.
@altamashsayed5264
@altamashsayed5264 2 жыл бұрын
@@ElectricalInfinity appreciate your reply..
@anwarullakhayoom7863
@anwarullakhayoom7863 Жыл бұрын
Always cable +breaker is sized as per continous current of the Transformer + consider the derating factors for grouping depth of laying and Thermal withstand capacity. and also the voltage drop . all calculated precisely.
@tharserohit
@tharserohit 2 жыл бұрын
Bhai single phase meter kitna load leta he
@swapnilshiyaniya5306
@swapnilshiyaniya5306 Жыл бұрын
Time 11:04 When you are calculating MCB for 2BHK load, you multiplied 5kw by 1.9 ... but wo to 3 phase ke liye aayega na ... for 1 Phase 5.43 Amp aayega na as 5 kw load is Single Phase load. Please correct me if i am wrong.
@Aliajikar89
@Aliajikar89 2 жыл бұрын
Raw power is done ...Sir plz added ups power....
@tamaghnadutta1644
@tamaghnadutta1644 2 жыл бұрын
From where I can get the Standerd chart of Transformer , Cb e.t.c
@ElectricalInfinity
@ElectricalInfinity 2 жыл бұрын
You can get Transformer standard sizes from supply authority and cb sizes from manufacturer manuals or datasheets.
@anwarullakhayoom7863
@anwarullakhayoom7863 Жыл бұрын
Buy TNEB Hand book.
@itz_tipzy5949
@itz_tipzy5949 2 жыл бұрын
Where is the standard to be exact for 2bhk 5kw energy meter and 3bhk 7.5kw? I need to furnish it for a project of mine...
@ElectricalInfinity
@ElectricalInfinity 2 жыл бұрын
IS 13010
@itz_tipzy5949
@itz_tipzy5949 2 жыл бұрын
@@ElectricalInfinity thank you so much
@itz_tipzy5949
@itz_tipzy5949 2 жыл бұрын
@@ElectricalInfinity can't find it in there... Is it mentioned explicitly that for a 2bhk this much capacity energy meter and so on... I have calculated loads of all flats individually but even after taking into diversity factor the load is quite large...
@itz_tipzy5949
@itz_tipzy5949 2 жыл бұрын
@@ElectricalInfinity also if I could discuss it with you somwhere else..
@ElectricalInfinity
@ElectricalInfinity 2 жыл бұрын
It's a general thumb rule contractor follows for considering total load. Usually it's 0-10 amps, 10-20amps and 20-30 amps energy meter rating.
@shaneefh926
@shaneefh926 2 жыл бұрын
For 19 amp y we use 40 amp breaker+
@mangeshdalvi842
@mangeshdalvi842 3 жыл бұрын
Whay about shop, if considerd?
@ElectricalInfinity
@ElectricalInfinity 3 жыл бұрын
Well we need add total load of the shop and consider demand factor as 0.8 to 0.9 for commercial places.
@AbidKhan-tj6en
@AbidKhan-tj6en Жыл бұрын
Ipad kaun sa hai bhai btana lena hai mujhe
@sherifgamal730
@sherifgamal730 2 жыл бұрын
Can i have this Sheet you write in the video please?!
@VijayKumar-qx1kr
@VijayKumar-qx1kr 2 жыл бұрын
IN FOUR POINT HOW WILL YOU DESIGN THE PANEL?
@electricalconcept32
@electricalconcept32 2 жыл бұрын
Sir can you tell me if load is 868KW, power factor is.0.8 and voltage is 415v and the cable length is 138meter. Which size cable we should chose to have maximum voltage drop of 3 percent
@anwarullakhayoom7863
@anwarullakhayoom7863 Жыл бұрын
Calculate VD on actual current , Not on Derated Current. Derated Current is only for cable+Equipment selection.
@mudassariqbal8532
@mudassariqbal8532 Жыл бұрын
You should explain it according to any international standard,
@sumanbepari609
@sumanbepari609 2 жыл бұрын
How a flat will use 3 phase???
@ElectricalInfinity
@ElectricalInfinity 2 жыл бұрын
All loads are distributed equally among each phase of 3 phase supply. Usually the loads are single phase for example lighting circuits and power loads. If it's 3 phase load then a 3 Phase supply is provided.
@sumanbepari609
@sumanbepari609 2 жыл бұрын
@@ElectricalInfinity sir, then there are SPN inside the room which are not showing here???
@anwarullakhayoom7863
@anwarullakhayoom7863 Жыл бұрын
upto 3KW - 1PH /240V IS enough , >3kw opt for 3ph 415v.
@kobe8502
@kobe8502 Ай бұрын
It would be great to explain this slowly. Kind of confusing and some details were not explained properly. Why did you use 400A in 9:52?
@khan__123
@khan__123 2 жыл бұрын
Bhai ye pen kaha se magbaye
@ElectricalInfinity
@ElectricalInfinity 2 жыл бұрын
Logitech
@mustafaidris6476
@mustafaidris6476 3 ай бұрын
Thank u , but its very fast way so As you r trading from papers
@outofthebox6027
@outofthebox6027 2 ай бұрын
Sir can you share the notes??
@prithivi5440
@prithivi5440 Жыл бұрын
Hloo bro can you share your linked in profile?
@mohammedezaj1018
@mohammedezaj1018 3 жыл бұрын
Where is cable sizing, voltage drop, sc calculation?
@ElectricalInfinity
@ElectricalInfinity 3 жыл бұрын
Will make another video for that. The video would have become lengthier if added everything you asked for.
@mohammedezaj1018
@mohammedezaj1018 3 жыл бұрын
@@ElectricalInfinity Thank you
@everything7790
@everything7790 2 ай бұрын
1 KVA = 1.9 anybody explain please in my calculation its is 1.39 something
@mobilesandcomputers5931
@mobilesandcomputers5931 2 жыл бұрын
ONLY I NEED YOUR ONLY FEW TIME IF POSSIBLE I WIST YOU GIVE ME POSITIVE RESPONSE
@md.gufranansari9672
@md.gufranansari9672 3 жыл бұрын
This video already you had made
@ElectricalInfinity
@ElectricalInfinity 3 жыл бұрын
Steps 4 and 5 are different. This one is for high rise building not g plus 5. Watch it full you will know the difference. 😊
@farazuddin7160
@farazuddin7160 8 ай бұрын
they said three lift but write only two lifts
@notfalcongaming7839
@notfalcongaming7839 2 жыл бұрын
Hlo
@peopleofkpk5558
@peopleofkpk5558 Жыл бұрын
Very interesting but your vedios is too much fast 🙈
@ElectricalInfinity
@ElectricalInfinity Жыл бұрын
Thanks and sorry for that. You can use reduce the speed to 0.8x while watching
@9852626796
@9852626796 Жыл бұрын
Just now I seen your video it's outstanding. Can I get this elaborated topic in pdf format please.
@ElectricalInfinity
@ElectricalInfinity Жыл бұрын
Thanks 😊
Identify equipment in a substation (35 - Electricity Distribution)
10:59
Я обещал подарить ему самокат!
01:00
Vlad Samokatchik
Рет қаралды 8 МЛН
Discover the Secrets of Electrical Designing & Drafting: WhatsApp +91-9848699535
35:49
SM Techno MEP Training Services
Рет қаралды 186 М.
MCB Types and their Applications || Types of MCB
8:30
Electrical lectures
Рет қаралды 65 М.
The Electrical Distribution System
12:35
TEGG Service
Рет қаралды 374 М.
Cable Tray Size Calculations | Cable Tray Selection | Electrical Designing
6:26
6 Electrical Engineering Project Ideas for This Summer
12:51
Ali the Dazzling
Рет қаралды 21 М.
Busbar sizing
9:27
stephen brooks
Рет қаралды 129 М.
Power & Distribution Transformer | What are the differences | TheElectricalGuy
10:30
Gaurav J - TheElectricalGuy
Рет қаралды 9 М.