Electrical Service Conduit Installation - Underground Power From Transformer

  Рет қаралды 140,533

The Excellent Laborer

The Excellent Laborer

Күн бұрын

This video will show you how to do an electrical conduit conduit installation for underground power. Electrical conduit in this video is schedule 40. Electrical conduit is for underground power from the transformer to the meter on a house.
🟡 Show your thanks and help support the channel with a donation! 👉 www.paypal.com/donate?hosted_...
🔴Subscribe for more home building tips to save a TON of money here: kzbin.info...
🔵Product affiliate links: (DISCLAIMER- I am an affiliate with the companies of the products listed below. I get a small commission that help support the channel at no extra cost to you)
⏱TIMESTAMPS⏱
0:00 Intro
Disclaimer: This video is all based on my personal opinion and is for entertainment purposes ONLY. I am not a financial advisor, CPA, attorney, tax advisor, electrician, plumber, housing contractor, designer, or any type of profession to give advice. I am just a consumer sharing my experiences and research. If you do need knowledge for those types of things, I will advise you to seek help for those professionals. .
🟡 Check out my Amazon store! 👉 www.amazon.com/shop/theexcell... . Here you will find tools and supplies used in my videos. (DISCLAIMER- I am an Amazon affiliate. I get a small commission that help support the channel at no extra cost to you)
🔴 Subscribe for more home building tips to save a TON of money here:
kzbin.info...
Disclaimer: This video is all based on my personal opinion and is for entertainment purposes ONLY. I am not a financial advisor, CPA, attorney, tax advisor, electrician, plumber, housing contractor, designer, or any type of profession to give advice. I am just a consumer sharing my experiences and research. If you do need knowledge for those types of things, I will advise you to seek help for those professionals.

Пікірлер: 128
@techtipsforsolopreneurs6468
@techtipsforsolopreneurs6468 2 күн бұрын
You are amazing! I'm going to be able to do so much more than I thought possible using your videos!
@TheExcellentLaborer
@TheExcellentLaborer Күн бұрын
Thanks I appreciate that! I got a lot of videos in the making. Stay tuned for more!
@Johnthedagger
@Johnthedagger Жыл бұрын
You're the best at showing how things are actually done instead of telling or explaining. Great job everytime
@stevencross6461
@stevencross6461 2 ай бұрын
It’s cool to see someone who is truly passionate about their work. Your videos helped me do my own subpanel in my detached garage. Probably saved me $1,000s.
@joshemajavich799
@joshemajavich799 Жыл бұрын
Thanks Mr electrician I know sometimes it's hard to work doing pipeing at the field thanks again for share your experience and greeting from Miami Florida.
@baitsinthewater95
@baitsinthewater95 2 жыл бұрын
Stumbled across your channel. You're a beast! Thanks for sharing your knowledge for us DIY folks out here!
@TheExcellentLaborer
@TheExcellentLaborer 2 жыл бұрын
Thanks! I hope your projects are going well. I appreciate you watching!
@jackcampbell7010
@jackcampbell7010 2 жыл бұрын
Great video! You are by far the most informative person on residential construction. Keep up the good work!
@TheExcellentLaborer
@TheExcellentLaborer 2 жыл бұрын
Thanks a lot Jack! That is the goal of my channel is to inform the world about residential construction. Thanks for watching!
@gavinnewscum
@gavinnewscum 2 жыл бұрын
Excellent video and pride of quality workmanship
@myfund1
@myfund1 Жыл бұрын
great stuff This is one of the best channels Ive seen. Thanks!
@cyrusparsaei1441
@cyrusparsaei1441 2 жыл бұрын
You got my attention man with your nice clips. Subscribed.
@CyYates1
@CyYates1 2 жыл бұрын
Great Job!!! Thanks for the info.
@JonDawson
@JonDawson 2 жыл бұрын
you are a rockstar! keep it up man!
@andrewbirkett715
@andrewbirkett715 Жыл бұрын
Great videos! Thanks for sharing
@bluefalcon3ID
@bluefalcon3ID 2 жыл бұрын
I would have loved this trench today. It was a heat blanket kind of Monday for me.
@derricksaunders5280
@derricksaunders5280 Жыл бұрын
Thanks a million.
@organogold8
@organogold8 Жыл бұрын
Thank you so much!!! 😊
@balloney2175
@balloney2175 Жыл бұрын
Awesome!
@fixitman8028
@fixitman8028 3 жыл бұрын
Nice video. Thanks
@TheExcellentLaborer
@TheExcellentLaborer 3 жыл бұрын
You are welcome. Thanks for watching!
@waynebeck7801
@waynebeck7801 Жыл бұрын
Thanks for the video..I have a similar situation. 3 conduits hydro, tel and cable. They will run up through the footings and stem wall B before we pour the concrete. Electrician wants 3000.00 labour 😅most of that seems to be gluing the conduit. Also installing the distribution panel.
@scothuggins3148
@scothuggins3148 Жыл бұрын
great video.
@rxh1013
@rxh1013 3 жыл бұрын
Thanks for this
@TheExcellentLaborer
@TheExcellentLaborer 3 жыл бұрын
No problem! Good luck with your project and stay tuned!
@engrizqureshi9532
@engrizqureshi9532 7 ай бұрын
Well done
@mattroyster1
@mattroyster1 2 жыл бұрын
Thanks Josh!
@TheExcellentLaborer
@TheExcellentLaborer 2 жыл бұрын
You are welcome Matt!
@jfromtn7410
@jfromtn7410 Жыл бұрын
have you ever used a ditch witch to dig a trench for the schedule 40 conduit?I have a new detatched garage about 60 ft from the transformer that I will need to
@davidburkholder7360
@davidburkholder7360 28 күн бұрын
Nice.
@john8855
@john8855 3 ай бұрын
Great video, I want to see how you pull those wires through from the transformer
@TheExcellentLaborer
@TheExcellentLaborer 3 жыл бұрын
The conduit is like a PVC pipe with a bell on one end more less. How about that?
@seanmithelman6316
@seanmithelman6316 Жыл бұрын
if you have the equipment to dig ad backfill yourself, how do you figure out how deep to go and how to get it at a decent rise/ angle to make it to the house? also once that it connected to the house, does that have to be inspected before you can go ahead a fill it back in and does the electrical company have to turn on the power or who do you call for that?
@framnerdan
@framnerdan 3 жыл бұрын
Great video Josh. Jack of all trades eh! Did you pull the electrical permit? Is your home parched already then sealed with tar?
@TheExcellentLaborer
@TheExcellentLaborer 3 жыл бұрын
Thanks Amazing! I try to do all trades. When you build a new house you pay for all the electrical, plumbing, and framing permits at once. Yes the black foundation coating you see is the sealer.
@bnbcraft6666
@bnbcraft6666 2 жыл бұрын
I do this kind of work, it's alright it pays the bills
@michaelaubrey1020
@michaelaubrey1020 2 жыл бұрын
How did you know where your stub was coming out I'm fixing to try to do this for my garage appreciate you thanks for sharing
@daltonbowie437
@daltonbowie437 2 жыл бұрын
Blueprints
@gtabraham3454
@gtabraham3454 Жыл бұрын
Something called a redhead. It's a marker that sticks out of the ground. Dig up the dirt around it and it should be at the very bottom of it.
@johnross3752
@johnross3752 3 ай бұрын
Can you use 3 inch pipe with long sweep inside the concrete form ?
@TheExcellentLaborer
@TheExcellentLaborer 3 ай бұрын
I don’t see the problem with that. Should be fine. as long as the power company can pull the cable through. You can always check with the power company and/or local building codes for clarification. I hope that helps!
@antoniohernandez7171
@antoniohernandez7171 2 жыл бұрын
I’m new to the commercial electrical trade, I doubt you’ll see this.. but if the prints specify rigid 90’s for the stub ups, do you have to do it? Or can you get away with a pvc 90 for the inspection?
@johndavies2949
@johndavies2949 5 ай бұрын
Sounds stupid but the reason is they are scared the pulling rope will burn through the radius of the 90 so they want steel or imc. It's a real bitch wrestling a 2" or 3" steel sweep. Consider yourself lucky that they accept pvv sweeps. I worry about the connection between the sweep and the straight pipe feeding into it when it comes to pulling in the wires as I have had the plastic coupling break right there on a tough pull.
@mos8541
@mos8541 Жыл бұрын
BRO! you gotta extend that shoe on the recip out! Keeps the blade tip beyond your piece. WHO/HOW dug that trench?! thats the hard part, esp. in AZ with no ACTUAL dirt, just rox LOL
@chaddavies2319
@chaddavies2319 2 жыл бұрын
I have a question about hooking up a meter socket and panel using 350 kcmil cable. The lugs won't accept that size cable. What can I do here? Use a pin adaptor? cut several strands out until the cable fits? Thank you
@keithharrington8715
@keithharrington8715 Жыл бұрын
They should make lugs for your situation. Please, please, never cut strands out of the cable. It reduces your wire size.....that means it will not carry the current it is rated for.
@Stormorbiter
@Stormorbiter 7 ай бұрын
Sometimes yes you can use schedule 40, but it would just typically need to be buried deeper. Very important to check your local codes to see what type of conduit you need for burial
@stickfigure9662
@stickfigure9662 Жыл бұрын
Does the conduit/trench have to be inspected for depth? Or can you just backfill it and the inspector usually takes the homeowners word for it as to the trenches depth.
@Stormorbiter
@Stormorbiter 7 ай бұрын
It depends on the inspector. Sometimes they’ll even accept a picture of the trench and be like yeah that looks like it was deep enough
@yemarican
@yemarican Жыл бұрын
Nice work man .. I'm not an electrician and I dont do this kind of work, but when you said the mice ate that string ..or rope .. how are you gonna run a new one and how did mice get there?
@TheExcellentLaborer
@TheExcellentLaborer Жыл бұрын
Evidently the mice came through the transformer. I had to contact the power company to open up the box and they help me fish a new rope through. Thanks for watching!
@minnesnowtan9970
@minnesnowtan9970 9 ай бұрын
Never expected the rope to be chewed, but that is why we do conduit. It would be interesting to see the ball with another string blown through. Is the wire hard to pull?
@somchai4046
@somchai4046 7 ай бұрын
thought same thing if it was capped, how did mich get in?
@salvatoreguiliano2429
@salvatoreguiliano2429 2 жыл бұрын
Hello Excellent Laborer, What the string in the Pipe is used for? Infinite thanks for your videos, you are a blessing to us,🙏🙏🙏.
@TheExcellentLaborer
@TheExcellentLaborer 2 жыл бұрын
The string is used by the power company to pull the service wire through the pipe. I hope that helps clear the air. Thanks for watching!
@rudyardgomeas6042
@rudyardgomeas6042 Жыл бұрын
I believe it depends on distance, for voltage drop and the size of service
@squirrelmaster5485
@squirrelmaster5485 10 ай бұрын
Whats the radius of that elbow you used?
@sevendust07660
@sevendust07660 6 ай бұрын
How far to space off the house if I have ledge stone with hardie plank above it?
@livewire500
@livewire500 3 жыл бұрын
I am building my house on vacant land I have a question so the electrician is the one who has to install the underground PVC pipe and electrical Conduit from the pole/transformer, do he also dig the trench or do i need to hire someone else? just to get a rough idea how much do you charge for this job. Thanks
@TheExcellentLaborer
@TheExcellentLaborer 3 жыл бұрын
My excavator dug the line. The electrician or excavator would install the conduit. It all depends on the person if they do or don’t do it. Good question. Thanks for watching!
@RafaelSwit
@RafaelSwit 4 ай бұрын
Nice job! Will electric company allow a DIY trenching and laying down the conduit? I’d like to bury the above ground power line that comes from the street post to the house. Don’t mind to do the work, if it can save me some money.
@eye2heaven
@eye2heaven 3 жыл бұрын
Good job! Who is going to hook up the wire to the transformer and meter?
@TheExcellentLaborer
@TheExcellentLaborer 3 жыл бұрын
Thanks man. The power company does that.
@treybtrucks
@treybtrucks 3 жыл бұрын
What was the depth (from grade level) of the existing capped end from the transformer? Good video. Thanks man! 👍🏻
@TheExcellentLaborer
@TheExcellentLaborer 3 жыл бұрын
It was about 3 foot deep. Thanks for watching!
@mkmac9539
@mkmac9539 Жыл бұрын
Great video. I will be installing electrical cable in conduit for ground mount solar panels soon. I will have to go about 200 ft. To make the "pull" easy my thought is to slide each 10 ft piece of conduit onto the cable from each end and stop in the middle. Then glue the conduit together. Continue this until all the cable is in the conduit. I dont see that anyone does it this way. Is this reasonable? Will this work? Any downside to this?
@keithharrington8715
@keithharrington8715 Жыл бұрын
The National Electric Code wants you to put the piping (conduit) to be fully installed before you put wire in it. I expect the wet glue will either destroy your wire's insulation when wet or glue the wire in place. Since solar installs are modular. (Add more if you need), I encourage you to consider a large pipe. There is minimum size pipe based on the number and size of your wires....minimum size. If you put in a larger pipe, you can add or replace the wire, use the old ones like a rope for the new ones, without re-digging the trench. Also, while your trench is open, consider a second or third pipe for power to lights or a data run for cameras or monitoring equipment. If The trench is open, it is an easy install and just cap them until you need them.....no re-dig. Hope that helps.
@mkmac9539
@mkmac9539 Жыл бұрын
@@keithharrington8715 That makes sense. Thanks.
@boycemontez4962
@boycemontez4962 Жыл бұрын
​@keithharrington8715 wjy size of conduit is recommended for the setup you're describing? I need to run service from my home to a small woodshop within 10 feet from the back of the house and wasnt sure to use 2"or 2½".
@johncarr123
@johncarr123 8 ай бұрын
Does the power company supply the schedule 40 from the transformer to the house?
@TheExcellentLaborer
@TheExcellentLaborer 8 ай бұрын
I had to buy the conduit and install it before the power company would pull the wire through. Contact your local power company and see what they want you to do is what I would recommend. I hope that helps.
@johncarr123
@johncarr123 8 ай бұрын
thank you for the quick reply and thank you for the excellent videos.
@ktm3850
@ktm3850 Жыл бұрын
Looks like there is a bit of a curve , sweep to it in the trench. I assume that's acceptable. Not always going to be perfect, straight.
@markabdrabbo
@markabdrabbo 2 ай бұрын
How many inches is the trench that looks like more than 18 inches
@mikem5454
@mikem5454 2 жыл бұрын
Is that 3"? What size wire are they pulling through that? How big is the service?
@TheExcellentLaborer
@TheExcellentLaborer 2 жыл бұрын
It is 3” and the power company pulled the wire through for a 200 Amp service. Hope that helps!
@joeyprather4739
@joeyprather4739 Жыл бұрын
I need to run 2 4” schedule 40 ducts for phone lines. Need 430’ and it’s going for $10 a foot if I can even find it. Incredibly expensive.
@jdubya54
@jdubya54 3 жыл бұрын
can u put wire thru pipe. then glue pipe then put down in trench
@Chrissers2010
@Chrissers2010 3 жыл бұрын
I believe the power company runs the wire from the transformer to the meter.
@TheExcellentLaborer
@TheExcellentLaborer 3 жыл бұрын
Yes the power company does run the actual service cable in the conduit.
@andrewallen8764
@andrewallen8764 6 ай бұрын
Whats the space between the house and the conduit?
@julian777ju5
@julian777ju5 Жыл бұрын
Thanks
@StraitClownin909
@StraitClownin909 8 ай бұрын
Not bad kid
@rachelweber4583
@rachelweber4583 3 жыл бұрын
What size conduit do you use? Tia
@TheExcellentLaborer
@TheExcellentLaborer 3 жыл бұрын
3”
@legitbenz
@legitbenz 2 жыл бұрын
Did you use schedule 40 or 80? Thx
@coriding
@coriding 2 жыл бұрын
It was Sch 80 (answered a few questions below)
@HughMyronM8
@HughMyronM8 2 жыл бұрын
Which wire is rated for underground and in conduit?
@mikhaelkozik6455
@mikhaelkozik6455 2 жыл бұрын
So no primer? Or u using something thats has primer?
@craiglindsey4529
@craiglindsey4529 2 ай бұрын
I know I am late to the conversation, but why 4" conduit?
@johndavies2949
@johndavies2949 5 ай бұрын
I didn't think you could come out of ground and up to the meter base with pvc. Did you use schedule 80? In my area the utility company makes the rules and even for a 200 amp single phase service they require 3" pvc in the ground with a 3" sweep and then transition to ridgid or imc coming out of the ground to the meter base. The problem is that most 200 amp meter bases only have 2" knock outs. The utility doesn't care. I have to pullna 3" hole and wrestle in that 3" rigid. Then the utility pulls in the triplex, which is rated for direct burial but you gotta have a sand base, then cover with sand once they put the wire in, have them look at it before snd after. A big hassle. So everyone uses the 3". And they pull in aluminum treplex. They make the lineside connection to the meter base. I make the liad side, usually before they get there. And the triplex has been really derated. They don't care. They don't have to. They are mot subject to the NEC.
@edmirk5498
@edmirk5498 2 жыл бұрын
The 2x4 block makes the pipe look like 4", but you replied it is 3"? At 3:03 the block is side by side to the pipe.
@vanghost4life
@vanghost4life 2 жыл бұрын
Dude, how much would it cost for 63ft power line run from the garage to the house. I am looking at quotes and they all over . Appreciate it.
@keithharrington8715
@keithharrington8715 Жыл бұрын
I am an electrical guy. You do not need years of training to do that hook-up. If you have the time and ability, you could do most or all of the job yourself to save on labor costs. There is a lot of rules for electrical work, so research the heck out of it. Maybe talk with a local electrician about being a consultant.....getting you the rules and some techniques to get the job done. Also, for a garage, a pro might get a problem solved before you know you have one. Consider adding extra pipes in your trench. If your garage becomes a shop, you might need Internet or security cameras or maybe a flashing light (diner bell) for emergencies in the house for those times when the noise lever is high. If your trench is open, it is just some pipe, but figure out you need to hard wire some internet out there after you close your trench and you might be digging a new trench. Hope that helps.
@looloo6322
@looloo6322 Жыл бұрын
Our electric company won't pass the 90 degree sweep, we have to use a hockey stick, where we then need a 45 and a 22.5 elbows. also the want purple cleaner on the pipe before the cement.
@nickk05281982
@nickk05281982 6 ай бұрын
How much did you pay for your slip joint?
@robertochavez8196
@robertochavez8196 3 жыл бұрын
How deep should schedule 40 be buried?
@TheExcellentLaborer
@TheExcellentLaborer 3 жыл бұрын
Check your local building codes. We always go at least 24” deep.
@SuperMudMuppet
@SuperMudMuppet 2 жыл бұрын
What size PVC conduit is that
@TheExcellentLaborer
@TheExcellentLaborer 2 жыл бұрын
3”
@shaneogden7392
@shaneogden7392 10 ай бұрын
Does your 200A meter base have built in 3" knock outs? If so, what's the manufacturer? Thanks 🇨🇦
@user-qf8xz8yp7x
@user-qf8xz8yp7x 10 ай бұрын
You needed to clean the dirt off of the conduit after removing the cap for the first bell with PVC pipe cleaner.
@fisforfriendship6093
@fisforfriendship6093 Жыл бұрын
so you dont have to use pvc primer then glue? because this is just wire being ran through not water where high pressure is present.
@carlosayala6754
@carlosayala6754 3 жыл бұрын
I do this job, but I lay hundreds of feet a day, sometimes we do 6 way bank with a lot of bends. This job isn’t easy.
@TheExcellentLaborer
@TheExcellentLaborer 3 жыл бұрын
Thanks for watching! Do you work for the power company or are you electrician?
@carlosayala6754
@carlosayala6754 3 жыл бұрын
@@TheExcellentLaborer apprenticeship right now.
@TheExcellentLaborer
@TheExcellentLaborer 3 жыл бұрын
@@carlosayala6754 Very awesome! Good luck to you!
@carlosayala6754
@carlosayala6754 3 жыл бұрын
@@TheExcellentLaborer thanks man.
@Chrissers2010
@Chrissers2010 3 жыл бұрын
Your elbow going into the house looks like schedule 80. Pretty heavy walled.
@TheExcellentLaborer
@TheExcellentLaborer 3 жыл бұрын
Yes it is. Schedule 80 is the elbows typically. Thanks for watching!
@marcusorillius6971
@marcusorillius6971 2 жыл бұрын
Collar or coupling? Never heard anyone call that a collar. 😏
@BlackVibeBallsack
@BlackVibeBallsack 2 жыл бұрын
That's a coupling
@azmrblack
@azmrblack 3 жыл бұрын
Why no primer?
@TheExcellentLaborer
@TheExcellentLaborer 3 жыл бұрын
Don't need it for this application.
@aparisi59
@aparisi59 3 жыл бұрын
@@TheExcellentLaborer i was curious about this myself.
@kylekayser2291
@kylekayser2291 2 жыл бұрын
Primer waste of time unless your putting in a waterline with pressure.
@azmrblack
@azmrblack 2 жыл бұрын
Thanks guys. I guess NEC states it is not necessary in powerline applications. I remember using Green cement when I did a short run of 1/2 inch buried PVC with UF cable for extra protection.
@mr.g937
@mr.g937 2 жыл бұрын
@@kylekayser2291 DWV uses primer and there is no pressure.
@cneiu
@cneiu Жыл бұрын
Con-Do It 😅
@TheExcellentLaborer
@TheExcellentLaborer Жыл бұрын
That’s right!
@cneiu
@cneiu Жыл бұрын
@@TheExcellentLaborer I appreciate the content! Thanks for sharing
@UAL012
@UAL012 2 жыл бұрын
Cool video. I'm wondering why you didn't have to use a rigid 90 to the house? Normally you're supposed to do that. Typically, you use schedule 40 90-degree bends with a 36 inch sweep from the transformer, DB120 for the straight runs and if you're going to a box, you use a rigid 90. The rigid 90 takes a female adapter with additional schedule 40 if needed. I work as a field superintendent for an underground company and we do this all the time.
@scottmcclenahan6681
@scottmcclenahan6681 7 ай бұрын
In your area, it's different everywhere
@stuartkorte1642
@stuartkorte1642 11 ай бұрын
For such a deep trench, I assume you didn’t use direct burial cable?
@keatonbradley5741
@keatonbradley5741 2 жыл бұрын
con do it
@TheExcellentLaborer
@TheExcellentLaborer 2 жыл бұрын
Good one!
Shed Electrical Installation (How to Add Electricity to a Shed - DIY)
12:16
Andrew Thron Improvements
Рет қаралды 657 М.
3M❤️ #thankyou #shorts
00:16
ウエスP -Mr Uekusa- Wes-P
Рет қаралды 13 МЛН
MEGA BOXES ARE BACK!!!
08:53
Brawl Stars
Рет қаралды 36 МЛН
I CAN’T BELIEVE I LOST 😱
00:46
Topper Guild
Рет қаралды 101 МЛН
How To Wire A Main Electrical Panel - Start To Finish! NEATLY And VERY DETAILED
43:50
The Excellent Laborer
Рет қаралды 2,9 МЛН
DIY Underground Electrical Service
7:14
LRR
Рет қаралды 45 М.
Bringing Electrical Service To Our Metal Storage Building
40:14
Pete B: East Texas Homesteading
Рет қаралды 69 М.
DIY Electrical Service trenching and conduit Installation
14:22
Daniel Woodell
Рет қаралды 264 М.
Overhead & Underground Electrical Utility Service
15:52
Electric Pro Academy
Рет қаралды 56 М.
DIY Pulling Buriable Electrical through PVC
5:29
RMSpeltz Farm - ReefDVMs
Рет қаралды 1,1 МЛН
Underground Electric Service Start to Finish
22:06
Tony's Tractor Adventure Homestead
Рет қаралды 15 М.
Replacing a Pad Mounted Residential Transformer
10:20
Randall Wingett
Рет қаралды 2,7 МЛН
телега - hahalivars #семейнаяжизнь
0:36
HAHALIVARS
Рет қаралды 1,9 МЛН
Обморожение Пальцев Альпиниста
0:18
Илья Калин
Рет қаралды 3,2 МЛН
Эй Рамазан # DamirAgroDizel
0:17
DamirAgroDizel
Рет қаралды 5 МЛН
😍🤤
0:20
Pavlov_family_
Рет қаралды 1 МЛН
You Can CHANGE Your Tesla Car’s Color?! #asher #shorts
0:36
Asher Lara
Рет қаралды 25 МЛН
телега - hahalivars #семейнаяжизнь
0:36
HAHALIVARS
Рет қаралды 1,9 МЛН