Electricians day fixing caravan site electrics TT

  Рет қаралды 7,472

CJR ELECTRICAL

CJR ELECTRICAL

Күн бұрын

Electricians day uk fixing caravan site hook ups .
Please support the charity any donations will get a shout out in the coming videos. 👇
2024tcslondonm...

Пікірлер: 48
@Cjrelectrical
@Cjrelectrical 8 ай бұрын
If you’d like to donate if not il disconnect your electrical supply. 2024tcslondonmarathon.enthuse.com/pf/chris-reeve?EnthuseSendGrid
@Cjrelectrical
@Cjrelectrical 8 ай бұрын
Thank you to everyone who has donated you are true legends.
@hughblount1983
@hughblount1983 7 ай бұрын
I love the rappor you 2 have o i used to love the banter with my old boss when i was doing landscaping work
@johnwaby4321
@johnwaby4321 8 ай бұрын
That's the trouble with changing old lights that are years old and trying to get something else to fit .👍👍 Nice bit of caravan site work .. Don't forget to mark the grey core blue . Make safe the floating black core ... I used to fit brass lock nuts to the swa glands to outside areas 👍👍👍👍
@markpunt9638
@markpunt9638 8 ай бұрын
Well done you on the marathon effort.
@steveb1856
@steveb1856 8 ай бұрын
Stayed on a campsite where all of the EHU cabling was Newley done but in YY cable, including coming out of the ground ( so presumably under ground Ito) and up to units with no additional UV protection!
@artisanelectrics
@artisanelectrics 8 ай бұрын
Welcome back 🎉
@CommercialGasEngineerVideos
@CommercialGasEngineerVideos 8 ай бұрын
Hear hear, he's back
@joebristowtechnologicalbre2073
@joebristowtechnologicalbre2073 8 ай бұрын
The new hook ups do seem to be all interlocked, costing the caravan park owners more money. It would be interesting to know why this regulation has changed. The park I do work at, has a small stock of existing non interlocked so I’ll be replacing like for like until they run out. As with all changes to the regs, you have to apply a bit of common sense and you can’t simply just trash everything that was fine yesterday and not today. You could put a label on it to warn the consumer, but as long as you can prove disconnection I wouldn’t give it a second thought.
@Cjrelectrical
@Cjrelectrical 8 ай бұрын
Very sensible answer this. They have created a solution to a problem that doesn’t exist. A simple isolate breaker before removing lead. 🤷🏻‍♂️
@bencampbell2041
@bencampbell2041 8 ай бұрын
Hope you have some good running socks. If they're not knee high will be disappointed.
@Cjrelectrical
@Cjrelectrical 8 ай бұрын
Just for you
@DS1-1a
@DS1-1a 8 ай бұрын
Static caravan and touring hook up units should have interlock sockets on them as per Section 708 of BS7671 18th edition. You have fitted a 17th edition version. Best go back to this job and change it so it complies.
@Cjrelectrical
@Cjrelectrical 8 ай бұрын
Integral switching device ie rcd in the box.
@dangallagher2306
@dangallagher2306 8 ай бұрын
Melt
@DS1-1a
@DS1-1a 8 ай бұрын
⁠@@Cjrelectrical unfortunately you still need to have an interlocking device built into the socket outlet or connected to the auxiliary contacts of the OCPD/RCD e.g an Eaton Z-Kam. Just for future ref.
@Cjrelectrical
@Cjrelectrical 8 ай бұрын
Have you looked at 6.1.5
@hbarnes2489
@hbarnes2489 8 ай бұрын
Must also have interlocking plug not just comply with 6.1.5 has to do both. Efix have a fantastic cpd on this. And lewden make a Fantastic product which they show off in the cpd training video. Hope this helps.
@Josh__Stevens
@Josh__Stevens 8 ай бұрын
That new hook-up needs to have interlocked socket outlets as per the 18th edition. Were those RCBOs Type A and Double Pole?
@Cjrelectrical
@Cjrelectrical 8 ай бұрын
Yeah double pole and type A no interlock. Maybe they use clause as the rcbo can be used as a toggle switch?
@Josh__Stevens
@Josh__Stevens 8 ай бұрын
@@Cjrelectrical the socket outlet can only be live with a plug inserted. Normal way is to have a rotary interlocked isolator incorporated into socket outlet (like Rolec do) or have a electronic interlock where there’s a micro switch that only lets you turn the RCBO on when a plug is inserted (caravan park electrical hook-ups achieve this using Eaton shunt trips, switched by a micro switch on socket outlet body, mechanically connected to the RCBO). Hope that helps, i would recommend you replace the unit you fitted in order to comply. That TLC hook-up looks pretty shit if I’m honest, probably some backstock!
@Cjrelectrical
@Cjrelectrical 8 ай бұрын
Over 40 on the site the client will not replace them. Bit like having an old plastic consumer unit more than likely a C3
@DS1-1a
@DS1-1a 8 ай бұрын
@@Josh__Stevens yes exactly, the Eaton Z-Kam unit connected to the aux contacts of the RCBO.
@Josh__Stevens
@Josh__Stevens 8 ай бұрын
@@Cjrelectrical it's not the fact of replacing them all. All new work needs to comply with the current regulations, so if you've changed the hook-up it needs to comply.
@Lacking_something
@Lacking_something 8 ай бұрын
Is there a safe way to run electric to an outbuilding on top of a border (behind shrubs)? Or does it have to be buried?
@Cjrelectrical
@Cjrelectrical 8 ай бұрын
Yes get us to do it. 👍
@anthonybragg
@anthonybragg 8 ай бұрын
@@Cjrelectrical Well answered
@Lacking_something
@Lacking_something 8 ай бұрын
@@Cjrelectrical I'd love to but I'm in Worthing, West Sussex.
@_eusty
@_eusty 8 ай бұрын
Challenge.... Who can take the most whacks on the back of the hand from a downlight spring... 😮
@Cjrelectrical
@Cjrelectrical 8 ай бұрын
Yes I like it
@Brown969
@Brown969 8 ай бұрын
You must be up a ladder, blindfolded and on a Friday afternoon otherwise it's not genuine 😂
@maximuspareo
@maximuspareo 8 ай бұрын
Hallo, 5:09 , in electric plastic box why do you connect earth wire to the box ? Is it plastic wright?
@Cjrelectrical
@Cjrelectrical 8 ай бұрын
It’s the TT earth spike you can’t see it on the underside of the box.
@maximuspareo
@maximuspareo 8 ай бұрын
I understand from begining that it is TT , but I do not understand why do you connect earth to the plastic box? Usualy we do this when we use a metal box... and even the door we connect separately , if metal box..
@dazzafat
@dazzafat 8 ай бұрын
He's not earthing the Box he's using a banjo connected to the Box to earth the armouring of the swa and the TT
@maximuspareo
@maximuspareo 8 ай бұрын
And by the way if it is tt , where is rcbo or rccb?
@Cjrelectrical
@Cjrelectrical 8 ай бұрын
The outlet has its own rcbo and the circuit is adequately protected.
@maximuspareo
@maximuspareo 8 ай бұрын
So the connection of earth conductor is useless in the box.
@Cjrelectrical
@Cjrelectrical 8 ай бұрын
Connect the earth of the 16amp outlet to the TT earth rod. Don’t use the Pme connection.
@mxslick50
@mxslick50 8 ай бұрын
I already gave the consequences for the loser on your other video..but for the challenge, perhaps a timed test for changing out 2 light fittings each, (will need a job with four or more identical fittings of course) fastest wins, loser....well you know what happens, lol.
@gordonburns8731
@gordonburns8731 8 ай бұрын
I pity James! I would certainly not be happy, being apprenticed to you. Although you may be highly skilled, you come across as unprofessional and condescending. I'm at the point of unsubscribing from your channel.
@Cjrelectrical
@Cjrelectrical 8 ай бұрын
Bye bye Gordon.
@ballybonting9318
@ballybonting9318 8 ай бұрын
Subjective analysis from @gd8731. CJR is doing a good job. Looks professional and definitely not condescending.
Smart Meter Disaster!!
16:33
Rygol Electrical and Renewables Bristol
Рет қаралды 469 М.
Man Mocks Wife's Exercise Routine, Faces Embarrassment at Work #shorts
00:32
Fabiosa Best Lifehacks
Рет қаралды 6 МЛН
Players vs Corner Flags 🤯
00:28
LE FOOT EN VIDÉO
Рет қаралды 95 МЛН
Spongebob ate Patrick 😱 #meme #spongebob #gmod
00:15
Mr. LoLo
Рет қаралды 22 МЛН
Incredible: Teacher builds airplane to teach kids behavior! #shorts
00:32
Fabiosa Stories
Рет қаралды 12 МЛН
Electricians day chippy had a good idea to hide the lighting driver.
14:23
This Was Terrifying - Supply Cable Blew UP
11:48
N Bundy Electrical
Рет қаралды 51 М.
Top 10 Beginner Mistakes When Building a DIY Solar System
17:39
DIY Solar Power with Will Prowse
Рет қаралды 1,1 МЛН
Normally just install 10mm for showers. Tsunami plumbing!!!
31:06
CJR ELECTRICAL
Рет қаралды 113 М.
Electricians day do you bother to fit Grommets? #electrician
13:20
CJR ELECTRICAL
Рет қаралды 8 М.
Electricians day testing and inspecting one of the worst installs.
20:35
WORST DIY ELECTRICS I'VE EVER SEEN! 🤯
22:52
Artisan Electrics
Рет қаралды 678 М.
Man Mocks Wife's Exercise Routine, Faces Embarrassment at Work #shorts
00:32
Fabiosa Best Lifehacks
Рет қаралды 6 МЛН