When your electricity Generator stops producing power, you need to know how to test the Alternator to find what has failed. This video will show you how to do this. Send us your results and we can tell you which part you need. Email us via our website generatorguru.c...
**If your generator has a Brushed Alternator please see our testing video "How to test your Electricity Generator's AVR, Brushes and Alternator on a Brushed Alternator."
If you have any questions please email us through your local Generator Guru website. We are always happy to help.
www.GeneratorGu...

Пікірлер: 308
@RadioTech7388
@RadioTech7388 3 жыл бұрын
Saved the day, tested 5 to 6 volts AC from coil and 20 uF capacitor testing only 15 uF. Replaced suspect capacitor for new 20 uF and output voltage returned just like magic. Thank you Generator Guru.
@Generatorguru
@Generatorguru 3 жыл бұрын
Always happy to help! You made our day by letting us know. Thank you.
@Generatorguru
@Generatorguru 3 жыл бұрын
We thank you for your interest in our help videos. Unfortunately, due to limitations in KZbins comment sections, we are unable to quickly answer questions in the comments. Please feel free to contact us directly here: www.generatorguru.com/need-help/
@teamstermancollier
@teamstermancollier 8 жыл бұрын
You guys have been a big help with me and my generator issues. I ordered some parts and installed them into my generator and am now just waiting on the rest of the 2nd round of parts I ordered so I can complete the repair and put the rest of my generator back together.
@davidbanwell7728
@davidbanwell7728 6 жыл бұрын
Thank you very much thank you very much I learnt a lot I will still keep a close eye on your channel keep it up good work
@ctomeiaviles
@ctomeiaviles 8 жыл бұрын
THANK YOU SO MUCH! You've been really helpful, and I appreciate it! I have a DeVILBISS PowerBack GT5000 and I didn't knew that has a capacitor inside the alternator cover. I did exactly what you said and... BINGO! 4 to 5 volts! I check with SEARS and they have it. Part# GS-0592. Hope this will help others! ...GOD Bless!
@Generatorguru
@Generatorguru 8 жыл бұрын
We are always happy to help! :)
@sammunyagwa2721
@sammunyagwa2721 2 жыл бұрын
I would like to thank you for the show up , you are such a good teacher. Please keep it up am following you always and i still need your help
@Generatorguru
@Generatorguru 2 жыл бұрын
Thank you! 😃
@CarlKahler
@CarlKahler 4 жыл бұрын
best video I have found
@timsharpe3498
@timsharpe3498 6 жыл бұрын
Good video. I just picked up a 5250 watt brushless generator. Hope I don’t need to fix it but you never know.
@tonytube7324
@tonytube7324 5 жыл бұрын
Thank you for the lesson for the capacitor I Needed to know how it works thank you for explaining it Helped a lot.
@Generatorguru
@Generatorguru 5 жыл бұрын
HI Cornelius Always happy to help! :)
@SSOMMERHOFF
@SSOMMERHOFF 5 жыл бұрын
Thank you!!! Just the advice I needed!!
@phoenixs0und
@phoenixs0und 7 жыл бұрын
Thanks for the reply,the 10uf cap measures 4.7uf so ill try replacing that as you say first.
@soubirajharree528
@soubirajharree528 7 ай бұрын
Hi can you show a test of the winding. I did the test...having around 5 v...replaced the capacitor also..still having output of 100 v instead of around 240v....thanks to help.
@Generatorguru
@Generatorguru 7 ай бұрын
Please set up a support ticket with our engineers and they will be happy to assist you. generatorguru.zendesk.com/hc/en-us P.s. We do NOT charge for this service
@xxwalhalaxxmozza7415
@xxwalhalaxxmozza7415 4 жыл бұрын
I’ve watched several videos about trouble shoot but most were avr which confused me, this is simple, relevant and took me straight to proving that my capacitor ‘which had burst open at the terminal end’ was fried, I crossed the terminal to make sure discharges then pulled it open and can see the melted insides and disconnected wire, it’s a Ducati 16uf on a Honda GX160 dont know who made alternator as plate missing, checked volts on the two wires with engine running as instructed and 6.7v so within tolerance I believe, is it better or worse to be 2v higher than lower or does it really not matter as long as it’s between 3&7v many thanks for your simple short video
@Generatorguru
@Generatorguru 4 жыл бұрын
Thanks for getting in touch. Replacing the capacitor should fix the issue. If the VAC output is a bit high it will might affect the longevity of the new capacitor. But.. if there are no surges on any equipment you attach, it should last for 100's (if not 1000's) of hours. ( We would also suggest you get an electrician to test what you last had plugged into the generator. Often it is faulty equipment that can cause this issue and make the capacitor overheat and blow.) We hold a whole range of generator capacitors on our website. www.generatorguru.com/capacitors/. :)
@normangengen3007
@normangengen3007 Жыл бұрын
hi generator guru thanks for handy tips .... tell me what cause the diodes to go bad on the rotar
@Generatorguru
@Generatorguru Жыл бұрын
Hi! This is usually due to overloading the generator, or if you have a faulty piece of equipment attached that is faulty and arcing and therefore asking too much of the alternator. If it keeps happening with the same equipment on (and you use lots of different stuff on the generator) then def get that equipment tested. As to overloading, be sure that you try to only load the generator 2/3 of max watts unless it is a GENUINE "Honda Generator" (i.e. not just the engine but the whole generator) then they rate theirs at 2/3 power for you. This allows for surges when things like motors start. Whenever you start anything there is a surge, and if it has a motor like fridges, freezers, drills) it normally takes about double the running watts to start it. Other stuff takes less and they do not need to move anything, just excite their components. Please also be aware there are many generators being sold on selling sites and "side of road" sales that are mislabelled and a scam. They will do this by putting a model number like 8500w to make it look like they give out that amount, when in fact they only give our about 2.8kw. If you are suspicious as to what your generator gives out and it keeps blowing AVRs or Capacitors, please contact us on our website www.generatorguru.com and we will be happy to identify it for you. (Hint - these are mainly common in EU. Framed versions that have a 3 phase sockets and 3 x 240v plug sockets and often have "kraft" in their name. There are also Inverter versions that are sold as 2000w but have a capacitor under the side flap (i.e. not an inverter and built to only give out 750w). Please contact us for full info on these units. They can still be used at lower power, but there are safety things you need to know if they have a 3 phase socket!)
@JakeMadz
@JakeMadz Жыл бұрын
Fantastic video!! With the new capacitor it has a different connection so how does it connect to the cables, can it work both ways?? If not then what test do I do?? Many thanks 😊
@Generatorguru
@Generatorguru Жыл бұрын
Thanks! That made my day! A capacitor is like a one way valve, so no. It can only be fitted one way. If you have to disconnect or switch the wires over, then be sure you discharge the capacitor or have safety gloves. It could give you a nasty burn otherwise. If you bought the capacitor from us please get in touch vis the website. We can direct you with more accuracy if we know which capacitor you have. :) generatorguru.com
@JakeMadz
@JakeMadz Жыл бұрын
@@Generatorguru thanks so much for your reply, do you have stock in the UK?? Also does it matter if the Microfarad rating was double my old one? Everything else is the same other than the UF!! Many thanks 🙂
@dandaman704
@dandaman704 Жыл бұрын
I heard you say so not use oil on the alternator. The bearings went out in my unit and i replaced them and also brushed the rust off the stator and rotor surfaces and applieda light coat of motor oil with a dab on a rag. Now it won't make power. Going to get some cleaner and see if i caused the fail with the motor oil.. fingers crossed
@dandaman704
@dandaman704 Жыл бұрын
I cleaned the oil off and still not making power. The 2 wires i disconnected from the capacitor are getting 4.99 vac with engine running
@Generatorguru
@Generatorguru Жыл бұрын
Ah! Yes oil gets sprayed into the Alternator when you do that. You should always replace the bearing with enclosed bearings that do not need oiling. Common mistake, so don't feel bad. But quite bad news really if you used enough oil that it has sprayed itself over the alternator. Oil will keep spreading to 1 micron thick, and will cover everything and cause arcing when the alternator is run if it has made it way to any wiring. If the oil has spread - You need to take the Stator (windings) off to take to a Motor Rewind Company to clean for you. The reason for this is because they will use special solvent and will oven dry it before you use it again (both needed to prevent further arcing.) Replace bearing with correct type as well. If the oil has not spread - then it is probably a failure from the original bearing failing. 4.99v looks good but we need to get you to do more tests to see if there was any damage done. Please contact our engineers on generatorguru.com/need-help/ > Engineering Support > I Dont Know, with as much info as possible and we will be more than happy to help with the next tests.
@echts
@echts Жыл бұрын
I operate a small portable concrete rig powered by a brushless generator. It consists of a 1hp motor (mixer) and a 1/2hp utility water pump . A pressure switch had been added to the water pump to prevent overheating/failure as water usage is intermittent . This worked fine for some years until the capacitor failed. Replaced and back to work . This new one also failed in 2 months time. I have 2 questions. First is could a water fitting leak cause the capacitor failure as it activates the water pump upon pressure loss ? This would increase the frequency of triggering the pump on/off for a few seconds as pressure recoupes. (Fitting to be corrected prior to capacitor replacement) . The second question is would adding an additional equivalent capacitor in parallel harm the generator ? The first failure was induced while using a 15amp breaker hammer with said water fitting leak (fyi). Thanks for any feedback.
@Generatorguru
@Generatorguru Жыл бұрын
Ok a lot to unpack there. We need to assign you to an engineer to run through the answers for you. But they need to know a bit more info: 1) What generator do you have? (if not sure what is the output on the label) If too small to account for the high surge getting the equipment running and keeping it going, will continuously blow the capacitor. 2) What are the amp readings on each piece of equipment you use on the generator, and what do you always use together? The amp ratings will be on a sticker somewhere on the equipment. 2) If water is leaking on the alternator, this can cause arcing and will blow capacitors and maybe more. Keep the alternator dry!!!! Once you got all this, copy and paste this thread and contact our engineers on generatorguru.com/need-help/ > Engineering Support > I Dont Know. We will assign you to an engineers who will be happy to work with you. FYI, we do not charge for advice. :)
@thomasschwarting5108
@thomasschwarting5108 Жыл бұрын
I have an older 5500 watt brushless honda generator pro series. Anyway this thing has no output. Checked the power going to the capacitor and I get just shy of 10 volts. It's not right I know because of your video. Is there anyway to compensate for that? I checked the voltage going to the capacitor and had 9.8 volts at governed speed. Slowed the running speed and got the voltage down to 7.6 volts. Can the voltage be compensated for?
@Generatorguru
@Generatorguru Жыл бұрын
Unfortunately no. If you change the speed of the engine, you change the hz output. :(
@weathermannax416
@weathermannax416 5 жыл бұрын
What if some have an in between sized capacitor?? My Campbell Hausfeld that produces 2,500 watts peak, 2,100 watts continuous and is powered by a flat head vertical shaft Briggs & Stratton 5 HP engine. It has a Facon brand 12.5uF (+-5%) 450 volt capacitor. The model number of the capacitor is 7G73125L62. The generator was bought new back in 1995. It current has 223 hours on it. It's used to keep the Amana upright fridge (7.2 amps running) going during a power outage.
@engineeringdept.generatorg1760
@engineeringdept.generatorg1760 5 жыл бұрын
Hi there Rounding to the nearest whole number is ok, please see the link below www.generatorguru.com/generator-capacitor-dry-cell-series-450v-12uf-5/
@bipa748
@bipa748 4 жыл бұрын
Hello, I would like to know if there is continuity between the capacitor and the incised winding? Greetings.
@jamesjordan7460
@jamesjordan7460 6 жыл бұрын
Excellent video Guru, I have a Generac XG8000E. I pulled the cap out and used my MM to measure the gen voltage and I am getting 1.5 volt, does this sound like a faulty cap? Thanks!
@engineeringdept.generatorg1760
@engineeringdept.generatorg1760 6 жыл бұрын
As your results are showing a low voltage so we suggest you “Flash” your alternator. Follow the steps below: 1. To re-excite your alternator, we suggest you only use this method, as described by Generac Generators on KZbin: kzbin.info/www/bejne/Y321Z2WpopyIibc 2. Run the generator for 20 minutes without load to stabilize the magnetic field in the Alternator. 3. Test with suitable appliance to make sure the load is stable. If not go to step 4. 4. Repeat our tests: www.generatorguru.com/help-me-fix-my-generator-repair-advice/ If results are below 1 Vac, repeat step 1. If this continues please contact us. If results are between 1-7 Vac, but you are not getting full voltage at the sockets, then you will need to replace your AVR/Capacitor. If results are above 8-10 Vac range, then you will need to replace your AVR/Capacitor. But be warned that the high reading will damage the AVR/Capacitor over time. This could result in it lasting a fraction of the time expected on a stable alternator. If results are above 10 Vac range, be sure you removed the AVR/Capacitor before testing. If you have and are receiving this result, we suggest you take your generator to a “Motor Rewind” company for repair. You can find your local Motor Rewinding company by doing a search on the internet for “Motor Rewind.” It is worth asking for a quote from a few Motor Rewind companies as their prices can vary greatly.
@joseantoniocastillohernand895
@joseantoniocastillohernand895 5 жыл бұрын
Buenos videos saludos de mexico oaxaca
@johnbuxton4035
@johnbuxton4035 4 жыл бұрын
I have a Makita g1200r Geny I rebuilt the carby and it worked fine, after shutting down to put covers etc back on I started the Geny and now doesn't out power.any idea's.ive tried the drill trick to no avail.
@engineeringdept.generatorg1760
@engineeringdept.generatorg1760 4 жыл бұрын
Hi there For fault finding or technical advice, feel free to contact us using the link below www.generatorguru.com/need-help/ This will allow our engineers to review your query and give you the best possible advice!
@sammunyagwa2721
@sammunyagwa2721 2 жыл бұрын
My promax 6000a 9hp vanguard generator is running but not producing power. What could be the problem ? It has taken long without using it , yet it was working since the last use.
@Generatorguru
@Generatorguru 2 жыл бұрын
Assuming your reading when running this test on the video were good. If it was sitting for over 6 months and produced power, then try flashing the alternator. (DonyBoy has a great video for this: kzbin.info/www/bejne/oqSxaoZnodqEsKM.) If flashing it does not fix the issue, you will need to replace the Capacitor. :)
@jamie260380
@jamie260380 2 жыл бұрын
Hi there. Thanks for this video. I have a Sdmo sh2500 that has stopped putting out electric. I have just done this test and it’s putting out a steady 9v. Is this to hi. Do I just get a new capacitor and try it. Many thanks
@Generatorguru
@Generatorguru 2 жыл бұрын
The results are very high. You can replace the capacitor but it will sooner or later blow the next capacitor... and/or worse... put out high voltage, blow the equipment attached too, possibly electrocute someone or cause a fire! So it is not a safe option.
@jamie260380
@jamie260380 2 жыл бұрын
@@Generatorguru many thanks for the reply, what would make it run high like this please.
@mogie620
@mogie620 5 жыл бұрын
Hi there, I tested my old etq 5000 generator and it reads 2.5v from those same leads you’re testing. I replaced the cap with a new one same ratings. When I test past those connectors to where the cap would be I get 1.5v any suggestions???
@engineeringdept.generatorg1760
@engineeringdept.generatorg1760 5 жыл бұрын
Dear Sir/Madam, As your results are showing a low voltage, we suggest you “Flash” your alternator. Follow the steps below: 1. To re-excite your alternator, we suggest you only use this method, as described by Generac Generators on KZbin: kzbin.info/www/bejne/Y321Z2WpopyIibc 2. Run the generator for 20 minutes without load to stabilize the magnetic field in the Alternator. 3. Test with a suitable appliance to make sure the load is stable. If not go to step 4. 4. Repeat our tests: www.generatorguru.com/help-me-fix-my-generator-repair-advice/ If results are below 1 Vac, repeat step 1. If this continues please contact us. If results are between 1-7 Vac, but you are not getting full voltage at the sockets, then you will need to replace your AVR/Capacitor. If results are above 8-10 Vac range, then you will need to replace your AVR/Capacitor. But be warned that the high reading will damage the AVR/Capacitor over time. This could result in it lasting a fraction of the time expected on a stable alternator. If results are above 10 Vac range, be sure you removed the AVR/Capacitor before testing. If you have and are receiving this result, we suggest you take your generator to a “Motor Rewind” company for repair. You can find your local Motor Rewinding company by doing a search on the internet for “Motor Rewind.” It is worth asking for a quote from a few Motor Rewind companies as their prices can vary greatly.
@fernandabalbinarovainadepi5156
@fernandabalbinarovainadepi5156 5 жыл бұрын
Tengo una falla en un generador de 8000watts, tengo que bajar la regulación del AVR , para arrancar , y después que arranca tengo que regularlo nuevamente al voltaje que trabaja, en esté caso es a 120voltios... Cuál será la falla ?
@miguelrd73
@miguelrd73 4 жыл бұрын
si no hay ningún voltaje en las puntas de donde se conecta el capacitor que prueba debo hacer para identificar el problema de que no genera voltaje? El generador que usamos es un Coleman Powermate Pro11000 que usa dos capasitores en paralelo y los dos son de diferente capacitancia y de diferente voltaje y solo uno de ellos es el que esta malo y es el de mas baja capacitancia. Gracias por sus consejos.
@miguelrd73
@miguelrd73 4 жыл бұрын
el capasitor malo es de 40 MF y 370 VCA saludos
@Mikesorrento3344
@Mikesorrento3344 6 жыл бұрын
Nice job! THANK YOU.
@SuperJesuselrey
@SuperJesuselrey 3 жыл бұрын
Hello, I congratulate you on your channel. I consult you, I have a Mrca Kubota AE2200 generator, it did not generate 220 volts voltage, it uses a 13 Uf capacitor, I made sure that the generator speed is 3600 RPM, and I changed the capacitor for another similar one (14 Uf) but it did not generate, and I did several tests with different capacitors, until when placing a 40 Uf capacitor, I got to generate 210 volts. I ask you what will be going through what needs more capacity. Saludos desde Lima Peru. Gracias.
@Generatorguru
@Generatorguru 3 жыл бұрын
Ok, lots of info. 1) ideally you need a 14uf capacitor or one within a 5% tolerance to get a stable electricity feed. You can get one here: www.generatorguru.com/capacitors/ 2) You need to flash your alternator as the magnetism has dropped out (generac do a great video with a corded drill.) 3) If this does not work, switch the wires on the capacitor around and follow step 2 again. If you still have issues please contact us via our website, and we will ask an engineer to assist you. www.generatorguru.com/need-help/
@edmundobarros3525
@edmundobarros3525 4 жыл бұрын
Amigo consulta, este tipo de generador no tiene AVR? Tengo uno muy similar y me entrega 5v a 6v en la conexión de 220v. Será que está malo el capacitor?
@Generatorguru
@Generatorguru 3 жыл бұрын
Please set up a ticket with our Engineers to discuss further as there could be a few reasons. (We do not charge for this service.) www.generatorguru.com/need-help/
@raymartinez2785
@raymartinez2785 3 жыл бұрын
I have a UST 5500 brushless generator and my capacitor keeps burning out and It doesn’t have an AVR and I cant find the problem. Any hint?
@Generatorguru
@Generatorguru 3 жыл бұрын
I am sure we can help. If you click here: www.generatorguru.com/need-help/ and go to Engineering>Alternator Issue>Need more help we can match you with the Engineer that specializes in your generator. He will be happy to assist you with the repair. :)
@brendanstack7833
@brendanstack7833 3 жыл бұрын
I have a Generator giving me a output of 230VAC at 41Hz After doing this test with the CAP disconnected I get a reading of 11.7Volts. Any advice on the cause of this or potential to rectify ? I believe this is causing a low frequency issue with generator
@Generatorguru
@Generatorguru 3 жыл бұрын
You need some further advice from our Engineers. Please contact them on this link and they will be happy to advise you for your generator: www.generatorguru.com/need-help/
@chewybacca4156
@chewybacca4156 2 жыл бұрын
Doing your test, I get 12 volts at the (removed) cap leads. with a 16uf cap I get 105 volts. with a 28uf cap I get 133 volts should I just try a 22uf? What would cause it to put out 12 volts instead of 5 volts? Thanks
@Generatorguru
@Generatorguru 2 жыл бұрын
Not quite. It will depend on the way the alternator was wound and the copper gauge of the wiring. I think it is best for you to set up a support ticket with our engineers. This way we can advise you particular to your generator. www.generatorguru.com/need-help/
@noside8469
@noside8469 7 жыл бұрын
i have a 6Kva diesel welding/generator.. having trouble to test its diodes... please help me thank you
@scottjackson5316
@scottjackson5316 5 ай бұрын
Is there any way to tell which wire is positive on a brushless gen when installing new capacitor.
@Generatorguru
@Generatorguru 5 ай бұрын
No sorry. If it does not work one way you will need to change the wires. See this video on capacitor discharge instructions:kzbin.info/www/bejne/boqziWSdj6ysgMk Disconnect it CAREFULLY as the capacitor could be holding a charge!!! Next... Hook the wires up the other way. It should then produce power. If it doesn't please contact our engineers on our website and they will guide you through the next step. :) www.generatorguru.com
@scottjackson5316
@scottjackson5316 5 ай бұрын
@@Generatorguru Thanks. I also wanted to ask about my surge power. My generator used to surge when I would plug in something big like a 5000 ac unit. But after storage and replacing the carb and capacitor it won't surge anymore. It still reads 115 volts but boggs on anything big. It's a 2000 surge 1500 continuous. It has almost no hours but was stored a long time.
@Generatorguru
@Generatorguru 5 ай бұрын
It sounds like you might be overloading the alternator! Please set up a ticket with our engineers via our website. We can then assign you to the specialist on your model and they can do the full calculations for you. :) generatorguru.zendesk.com/hc/en-us P.s. We do NOT charge for this service
@t-t5374
@t-t5374 6 жыл бұрын
Hi i have a 6kva generator with no power.. im geting 1.6v at capacitor connection wires with capacitor disconnected and its 2v with capacitor connected what you think? Thank you
@Generatorguru
@Generatorguru 6 жыл бұрын
Dear Sir/Madam, As your results are showing a low voltage, we suggest you “Flash” your alternator. Follow the steps below: 1. To re-excite your alternator, we suggest you only use this method, as described by Generac Generators on KZbin: kzbin.info/www/bejne/Y321Z2WpopyIibc 2. Run the generator for 20 minutes without load to stabilize the magnetic field in the Alternator. 3. Test with a suitable appliance to make sure the load is stable. If not go to step 4. 4. Repeat our tests: www.generatorguru.com/help-me-fix-my-generator-repair-advice/ If results are below 2 Vac, repeat step 1. If this continues please contact us. If the results are between 2-7 Vac, but you are not getting full voltage at the sockets, then you will need to replace your AVR/Capacitor. If results are above 8-10 Vac range, then you will need to replace your AVR/Capacitor. But be warned that the high reading will damage the AVR/Capacitor over time. This could result in it lasting a fraction of the time expected on a stable alternator. If results are above 10 Vac range, be sure you removed the AVR/Capacitor before testing. If you have and are receiving this result, we suggest you take your generator to a “Motor Rewind” company for repair. You can find your local Motor Rewinding company by doing a search on the internet for “Motor Rewind.” It is worth asking for a quote from a few Motor Rewind companies as their prices can vary greatly.
@gomonmesa7238
@gomonmesa7238 2 жыл бұрын
My brushless generator only puts out 170vac, tried new capacitor no difference, what would be the problem?
@Generatorguru
@Generatorguru 2 жыл бұрын
Pls contact our engineers on www.generatorguru.com/need-help/ and they will be happy to help. :)
@neiloliver01
@neiloliver01 6 жыл бұрын
Im getting a reading of 13.1 volts on the test, is this ok? its the exact same model generator as in the video.
@engineeringdept.generatorg1760
@engineeringdept.generatorg1760 6 жыл бұрын
please contact us via support@generatorguru.com the information is too extensive for the youtube comment section
@edinsonpalacio3234
@edinsonpalacio3234 2 жыл бұрын
Hola gracias por la información tengo un generador de dos polos sin escobilla 7.5 en 3600 rpm la tensión es 12 vol con condensador 30 microfaradios quisiera saber cual es el adecuado por fa
@Generatorguru
@Generatorguru 2 жыл бұрын
Dependerá de la forma en que se enrolló el alternador y el calibre de cobre del cableado. Creo que es mejor que configure un ticket de soporte con nuestros ingenieros. De esta forma podemos asesorarte en particular para tu generador. www.generatorguru.com/need-help/
@geebee5580
@geebee5580 Жыл бұрын
still good advice ty
@Generatorguru
@Generatorguru Жыл бұрын
Thanks :)
@patrickcannell2258
@patrickcannell2258 7 ай бұрын
Had the same issue yesterday.
@JakesMusicPalace
@JakesMusicPalace Жыл бұрын
Thanks for sharing
@Generatorguru
@Generatorguru Жыл бұрын
Thanks for watching!
@paulduncan5140
@paulduncan5140 Жыл бұрын
Capacitor was bad so I replaced it. Didn’t work. Tested voltage out of the leads to the capacitor and I am getting 18.6 volts??? Any help would be appreciated
@Generatorguru
@Generatorguru Жыл бұрын
It seems the Armature (rotor) diode has blown! You need to take the Armature (rotor) to a motor rewind shop and see if the can replace it. Alternatively, the manufacturer might sell replacement alternators, but be warned... They are expensive!!
@paulduncan5140
@paulduncan5140 Жыл бұрын
@@Generatorguru thanks. I appreciate the help.
@marianodominguez8155
@marianodominguez8155 3 жыл бұрын
what if ever with new capacitor, we have voltage oscilation from 180 to 230v?? thanks
@Generatorguru
@Generatorguru 3 жыл бұрын
Please contact our engineers via our help centre for 1-on-1 help. www.generatorguru.com/need-help/
@xenomorph7299
@xenomorph7299 4 жыл бұрын
great video thanks
@alexchambers3135
@alexchambers3135 7 жыл бұрын
Getting no power from my SIP medusa, the 10uF capacitor is testing as a complete dud. and the voltage from the alternator is 8.9VAC, you video says 5VAC ± 2. Am I too far out the desired range?? TIA
@engineeringdept.generatorg1760
@engineeringdept.generatorg1760 7 жыл бұрын
Dear Sir it is slightly too far out of range, you will blow any replacement capacitors you fit unfortunately, however you can take it to a motor rewind company to find out how much it would cost to be repaired
@tammymedlock9640
@tammymedlock9640 7 жыл бұрын
have a echo 5500 brushless generator,,, 2 ,,28uf capacitors wired parallel,, 2.53vac out of alternator,,, and can see wires got hot between alternator and first cap ,,,,low voltage and have cycle fuse to get start showing voltage bout 60vac
@Generatorguru
@Generatorguru 7 жыл бұрын
Tammy, we would love to help you with this. The reading seems to indicate replacing the capacitor should fix the problem. We sell replacement capacitors on our website on this page: www.generatorguru.com/capacitors/. I would also replace the burnt wiring, and inspect the windings to be sure there is not burn marks on the windings or burnt smells coming from the alternator (apart from that wire of course.) If there is, it indicates the windings overheated and the varnish on the windings might need revarnishing. This can be done by you local Motor Rewind Specialist. Hope this helps! If you need any further assistance please let us know.
@mithiraudugama800
@mithiraudugama800 6 жыл бұрын
Replacing the capacitor worked for me. Thank you. But still voltage is bit wavey(200-230v) . Any fix for that?
@engineeringdept.generatorg1760
@engineeringdept.generatorg1760 6 жыл бұрын
Hi there, does the generators revs vary? they should be constant and so should be the voltage
@mithiraudugama800
@mithiraudugama800 6 жыл бұрын
Styles Generator Guru yes engine revs very. Later i realized when i add around ½ of the full load . Voltage and engine get more stable. How can i fix it?
@engineeringdept.generatorg1760
@engineeringdept.generatorg1760 6 жыл бұрын
Hi there, is the generator a gasoline or diesel unit? This sounds like a slack governor, if you can tell us what generator you have, I can provide more detailed instructions
@mithiraudugama800
@mithiraudugama800 6 жыл бұрын
It's gasoline. It's AM950. I Think it is a Chinese clone of yamaha 950 , 800w generator or Harbour freight 800w generator.
@engineeringdept.generatorg1760
@engineeringdept.generatorg1760 6 жыл бұрын
Hi there, this means that one of the governor springs has slackened, I suspect the larger of the two, if you remove the fuel tank, the governor assembly will be right on top of the engine, one spring holding the arm in place and attached to the engine body and one over the governor rod that attaches directly to the carb, you need to ensure that both of these are taught
@naseerahmad-ze3rv
@naseerahmad-ze3rv 7 жыл бұрын
the best work
@stephenrosindale5095
@stephenrosindale5095 3 жыл бұрын
Hello ive testested my brushless alternator and im getting 11 to 12 volt why is this my capasitor is 13uf is that too small for a 2.7kva stephil
@Generatorguru
@Generatorguru 3 жыл бұрын
It seems you Alternator has blown it's diode. If you take it to a Motor Rewind Shop, they should be able to fix it for you. The uf on your capacitor should be matched to the winding length and diameter of the wiring. These vary from design to design. It is always advisable to stay with the same uf. If you use another, it will change the power output and make it less stable.
@xenomorph7299
@xenomorph7299 3 жыл бұрын
I have brushless generator and changed the capacitor but still reads only 1 volt at idle. the volts going to the capacitor read 5v so thats good. if i rev up the engine really high the volts increase to passed 120v. when i plug in a device the engine rpm doesnt increase and im only getting 1 volt at the socket. only way to increase volts is manually with carburetor so thats no good. can someone please help me? I checked the breaker and it is good.
@Generatorguru
@Generatorguru 3 жыл бұрын
It sounds like a dodgy capacitor or you have wirted it up backwards. Try switching the wires to see if this is the case. If you need a capacitor we sell them on our site www.generatorguru.com/capacitors/. If you still have issues please contact us via our website, and we will ask an engineer to assist you. www.generatorguru.com/need-help/
@TheZemun
@TheZemun Жыл бұрын
@Generator Guru Hi , I have a generator but mine is Honda em25 (2.3kw, 220v) cycloconverter generator but I got it without electronics (module and front panel), just engine with flywheel (drum) and coils inside . Is there any ways to bypass all of that and make it run ? Just to make engine running , I don't need current . Or any modifications regarding , Thanks
@Generatorguru
@Generatorguru Жыл бұрын
Must admit, not an expert on that generator. But the engine looks like a normal setup. 1st you might want to remove the alternator to see if the crankshaft connection is any good for your new project. Generators 90%+ of the time use a tapered shaft which is only really found on generators and due to the shape make it very difficult to use for other purposes. If you need another crankshaft type you will need to replace the crankshaft (or see last suggestion.) If your happy with the crankshaft connection and it is manual start you could take the alternator and most wiring off and it will run happily. Be sure not to remove any wires from behind the flywheel as this will be to your ignition coil or that go into the engine, or attach to what goes into the engine. If electric start you will need to fit a key start unit (search the engine model, Honda and key start on search engine) and keep all wiring for the starter motor, battery charging rectifier (finned on back) and battery. ALTERNATIVELY - sell it on ebay as "spares and repairs" and you might make enough to buy a new engine with the correct crankshaft for your project. We sometimes get asked for engines for these and they seem like gold dust these days. Hope this helps! The Generator Guru Team
@TheZemun
@TheZemun Жыл бұрын
@@Generatorguru Thank you so much for the advice . Thank you
@Generatorguru
@Generatorguru Жыл бұрын
Thanks for the feedback! Really helps us. :)
@garypitzer8729
@garypitzer8729 4 жыл бұрын
Humm mine got 10.6 volts ac the first test and 7.6 volts ac the second test. I wonder if my alternator is any good?
@Generatorguru
@Generatorguru 4 жыл бұрын
Hi there For fault finding or technical advice, feel free to contact us using the link below www.generatorguru.com/need-help/ This will allow our engineers to review your query and give you the best possible advice!
@bstack10
@bstack10 2 жыл бұрын
My generator is reading 11Volts AC with the capacitor disconnected. Any ideas??
@Generatorguru
@Generatorguru 2 жыл бұрын
That is very high. It suggests the diode in the rotor has failed and needs replacing. :)
@tjm52071
@tjm52071 4 жыл бұрын
Hi, I'm only getting 2 Vac from the wires going to my capacitor. BTW, my capacitor is a black rectangle. I assume that's the capacitor anyway.... Suggestions from this point ?
@Generatorguru
@Generatorguru 4 жыл бұрын
Hi there We find 2V to be quite borderline, sometimes in these cases, fitting a new capacitor instantly restores the voltage, sometimes it can take a few minutes to get up to full output, sometimes replacing the capacitor doesn't restore the output and further work is needed, we really cannot say for sure
@tjm52071
@tjm52071 4 жыл бұрын
@@Generatorguru Hello, thank you for the reply. I tried a new capacitor with no change. Can you suggest where to go from here ?
@Generatorguru
@Generatorguru 4 жыл бұрын
Hi there Did you run it a little while? Sometimes, the generator will re-excite itself gradually as you run it. If there is no change after 20 minutes or so, then follow the procedure in the video below To re-excite your alternator, we suggest you only use this method, as described by Generac Generators on KZbin: kzbin.info/www/bejne/Y321Z2WpopyIibc
@tjm52071
@tjm52071 4 жыл бұрын
@@Generatorguru Thank you for the reply. I ran it tonite for 24 minutes, no change. Still only 2.4 vac output. Will watch your other video and continue. Couple other questions first.... How picky is the capacitor ? The one i bought is slightly different. Specs: 14uf +/- 5% 450vac. My original is 14 uf, 300 VAC. Also, because it is different, how critical is polarity ?
@Generatorguru
@Generatorguru 4 жыл бұрын
Hi there It is the microfarad rating that is most critical, the voltage is less of an issue. Polarity shouldn't be an issue but you can try reversing the terminals, it sometimes does resolve the problem, capacitors are peculiar and picky items
@bobsteneck8502
@bobsteneck8502 Жыл бұрын
Thank you
@Generatorguru
@Generatorguru Жыл бұрын
You're welcome
@shelbystrickland1238
@shelbystrickland1238 6 жыл бұрын
We did the replaced the capacitor we are running 5 volts at the alternator but still not getting any power
@pastelfrisk2920
@pastelfrisk2920 3 жыл бұрын
My generator has a 50 uf. Can I put 47 uf and it still work
@Generatorguru
@Generatorguru 3 жыл бұрын
Soprry you need to match it within 5%. So you need a 47.5-52.5 uf. but a 50 uf will ensure correct operation so this is the best uf. If you need to buy we sell them on our site: www.generatorguru.com/capacitors/
@roohulameenameen7247
@roohulameenameen7247 5 жыл бұрын
Thank you sir plz tell us connection diagram of this type of generator.
@Generatorguru
@Generatorguru 5 жыл бұрын
Dear Sir/Madam, I am sorry to say we do not hold any manuals or wiring diagrams, as we are not affiliated with the manufacturer of this Generator. Instead, we work with the Manufacturers of the parts made to build the Generator. But we have Engineers here who have worked on your Generator a number of times. If you have any questions we would be very happy to advise you.
@roohulameenameen7247
@roohulameenameen7247 5 жыл бұрын
@@Generatorguru ok. Thanks
@basspig
@basspig 8 жыл бұрын
I've got a Northstar 13000 brushless generator set that's putting out only 111 volts at 61.5 Hz. Since there's no AVR on a brushless, what might be done to increase the voltage output to 120V per leg so that my refrigeration compressors don't struggle? If this capacitor is out of tolerance, how does it affect the voltage? Larger capacitance makes lower or higher voltage?
@Generatorguru
@Generatorguru 8 жыл бұрын
Sorry for the delay in answering, we were not aware of the question until today (no email from youtube.) We can give you more assistance if we can assign an Engineer to your question. Please, can you contact us with this question via our website, so we can send you full instructions? www.generatorguru.com
@basspig
@basspig 8 жыл бұрын
That was actually pretty fast! Will do. Thanks. I've been advised on the Smokestack forum that increasing the size of the capacitor would increase the voltage. Could be mine got one of the caps that fell into the minus side of tolerance.
@Generatorguru
@Generatorguru 8 жыл бұрын
DO NOT DO THIS! Your capacitor has been matched to suit the winding design and length. Increasing the capacitor will increase the voltage BUT it will also heat up the windings further than they are designed for. This will result in the varnish on the windings melting and resulting in the alternator arcing! You will damage the windings and they will either need replacing or rewinding (both are expensive!) Did you contact our engineers with the results from the test? Do not worry if a brushless unit we can still assit you. :) www.generatorguru.com/ask-the-guru/
@basspig
@basspig 8 жыл бұрын
That is an interesting point, but it IS a Chinese made genset and the voltage is too low for our enterprise UPS to consider it proper and keeps popping in and out of AVR Boost mode. Normal line is 122VAC and the genset puts out 111VAC at no load. The capacitors, based on the exploded view of the unit, are located in a metal box on top of the alternator. However, two of the screws that secure it are blocked by the electrical outlet panel on one side of the genset, so I have not been able to get in there. This is a new genset from Northern Tool, BTW. They won't do anything about it because it's within their loose 10% voltage tolerance. Anything between 108 and 132 volts is considered normal to them. But my a/c compressors and UPS don't like the low voltage.
@Generatorguru
@Generatorguru 8 жыл бұрын
Have you done the 50 hour service? If not please do this now to be sure the engine is running at the correctly If you are still having trouble please email us directly for the next test you require. (Too much info to post here) www.generatorguru.com/ask-the-guru/ We are always happy to help! :)
@HITNMISSNUT
@HITNMISSNUT 7 жыл бұрын
Thanks for sharing👍
@anyamy8080
@anyamy8080 7 жыл бұрын
Hi, I have Honda G300 Generator which is not producing an electric, what and how I can check the alternator whether it produce any voltage please?
@Generatorguru
@Generatorguru 7 жыл бұрын
G300 Is the Engine model so I would need to know more than this code to assist you with this query. But saying that this test can be run on all portable generators to test the health of the alternator before changing the capacitor or AVR (depending on which is fitted to your model.) If you can provide us with the model number or send us pictures of the end of the alternator with the cover removed, we can help you further. Please send pictures to us via our website contact us page: www.generatorguru.com
@anyamy8080
@anyamy8080 7 жыл бұрын
I am attaching some pictures for your consideration. _lh3.googleusercontent.com/LSDvRHIJnyoIO5ms1RSIHbGw-scladDQdG_c92Ux7RIfjcpMhd8KvodfO0HKVIUTeHT4lHEYAQ_
@Generatorguru
@Generatorguru 7 жыл бұрын
Unfortunately, KZbin will not let us see these pictures. Can you submit a ticket to us with the pictures and your questions please via our website. :) www.generatorguru.com/ask-the-guru/
@willweaver38
@willweaver38 4 жыл бұрын
I tested my alternator and it's producing 15 to 20 volts. Does that mean it's bad? My generator is a 5500 porter cable brushless
@Generatorguru
@Generatorguru 4 жыл бұрын
Dear Will, As your Alternator has failed the tests, you need to contact a local “Motor Rewind Company” to see if they can fix it. These companies can vary in price, so if you have time, it is worth getting a few quotes. This is a much cheaper option than replacing the Alternator as the manufacturer charges over ½ the price of a new Generator and we would still need to get it shipped to you from China. Being so heavy, that would be very expensive and outweighs the economy of a new Alternator.
@willweaver38
@willweaver38 4 жыл бұрын
@@Generatorguru thank you
@Seneb8Khepera
@Seneb8Khepera 8 жыл бұрын
Good day, I have a LAUNTOP 5000 Diesel generator that is running but oil is spitting out through the fuel vent. Anyone have any idea what the problem maybe and how to fix it??? We don't have a manual and having problems finding one online.
@Generatorguru
@Generatorguru 8 жыл бұрын
Hi! What do you mean by the fuel vent? Did you mean Air filter vent? If you have oil spitting out of anywhere on the top end then it probably is the Piston Rings failing, allowing the oil to rise in the cylinder. You need to remove the head and put a tablespoon of oil onto the piston and leave overnight. If the oil has disappeared you need to replace the piston rings. If it does not then it is probably diesel and the head will need carbon removal around the valves and the valves reseting. If you need the valve settings please contact our engineers on www.generatorguru.com/ask-the-guru/
@nickyogorman1590
@nickyogorman1590 3 жыл бұрын
Good video, my capacitor is good but I only getting 1.7 volts ?
@Generatorguru
@Generatorguru 3 жыл бұрын
Sometime capacitor show as good but fail under the high voltage. With the 1.7v it should excite the capacitor, so this indicates it has failed. To be double sure, you can flash the alternator. If you need a capacitor we sell them on our site www.generatorguru.com/capacitors/. If you still have issues please contact us via our website, and we will ask an engineer to assist you.
@mustafacaglar3338
@mustafacaglar3338 5 жыл бұрын
Harikasınız
@makinajenerator1525
@makinajenerator1525 5 жыл бұрын
Can I use this avr card for this
@makinajenerator1525
@makinajenerator1525 5 жыл бұрын
Avr8
@engineeringdept.generatorg1760
@engineeringdept.generatorg1760 5 жыл бұрын
Dear Makina Jenerator, Thank you for contacting Generator Guru! We would very much like to help you find the parts you require but need a bit more information before we can proceed with your request. Please, can you tell me the Make and Model of your generator? Alternatively, we have listed on our website over 500,000 parts for quick purchasing. Please search for you Make and Model to locate the parts we have available: www.generatorguru.com/categories/Make-%26-Model/ If you are unable to give either the Make or Model code, you can send us a picture of the generator from the front and the back, and of the part you require. With this our Engineers would be happy to identify it for you. You can respond to this request by replying to this message, emailing us on support@generatorguru.com, or by sending us pictures to our SMS number +1 (760) 300-3388. If you send the Pictures by a different form than how you received this message, please quote "Ticket number 85856." in the message so we can merge it with your support ticket.
@johanvanniekerk1248
@johanvanniekerk1248 Жыл бұрын
I have put a earth leage breaker in my generator and i have put a earth pun in the ground.. but my generator doesnt want to trip.. wat can be wrong
@Generatorguru
@Generatorguru Жыл бұрын
Hmmm... Ok lets assign your issue to one of our engineers. Please contact them to set up a ticket on generatorguru.com/need-help/
@xenomorph7299
@xenomorph7299 4 жыл бұрын
I bought a new capacitor because i thought that was the issue. new capacitor installed but still only reading 1v output where you plug in items to the generator. I tested the output of the alternator and im getting 3.3 volts where it connects to the capacitor. I tested the breaker switch and its fine low resistance. The generator has a briggs and stratton engine with a powerfist generator. The wires that come out of the alternator that go to the plug to plug in your items such as tools or whatever only reads fluctuating .8v to 1v. Any idea what is happening? Thanks guys and girls.
@xenomorph7299
@xenomorph7299 4 жыл бұрын
My capacitor that i bought is identical to the one that was in it. This generator has been sitting for quite a few years. like 8 years sitting.
@engineeringdept.generatorg1760
@engineeringdept.generatorg1760 4 жыл бұрын
Hi Marcel Does the generator have a voltage changeover switch?
@xenomorph7299
@xenomorph7299 4 жыл бұрын
@@engineeringdept.generatorg1760 No it doesnt :(
@engineeringdept.generatorg1760
@engineeringdept.generatorg1760 4 жыл бұрын
Hi Marcel Thanks for the update, the next thing to do is check the output legs, the test for this can be found on our AVR testing video, please have a watch and report back with the following results: R1 & R2 : L1 & L2 : R1 & L1 :
@jamesstubbins3510
@jamesstubbins3510 4 жыл бұрын
I have no voltage on the green wires on a Suntom SGE1000X Generator can you help me, i get AC power when I put a battery on the green wires.
@Generatorguru
@Generatorguru 4 жыл бұрын
Hi there For fault finding or technical advice, feel free to contact us using the link below www.generatorguru.com/need-help/ This will allow our engineers to review your query and give you the best possible advice!
@jamesstubbins3510
@jamesstubbins3510 4 жыл бұрын
@@Generatorguru Do the 2 winding on the rotor have to be in series with diode and resistor connecting the 2 winding together?
@DaVidJimenez-to6xj
@DaVidJimenez-to6xj 3 жыл бұрын
Hi Guru I'm getting only 1.6 volts any idea what could be wrong
@Generatorguru
@Generatorguru 3 жыл бұрын
It sounds like a dodgy capacitor, you need to flash your alternator, or you have wired it up backwards. If it is a new capacitor, try switching the wires to see if this is the case. If you need a capacitor we sell them on our site www.generatorguru.com/capacitors/. If you still have issues please contact us via our website, and we will ask an engineer to assist you. www.generatorguru.com/need-help/
@bombadeer8231
@bombadeer8231 6 жыл бұрын
Say GG, new sub here. I have an 1997 (guessing) Northstar PPG 8000 that I got with a blown cap. I replaced both as long as I was at it (Appli Parts Run Cap 12.5 uF, 370vac, 50-60Hz) and still no output. Do I need to flash the field and how do I do that? It's brushless. Great vid, thanks! PS/ In it was a Facon 12.5 uF and a Ducati 16 uF. The latter blew. Greetings from New Jersey btw.
@Generatorguru
@Generatorguru 6 жыл бұрын
Hi there Before flashing the field, disconnect the capacitors, run the generator and check the voltage inputs into the capacitors
@antonypt1829
@antonypt1829 18 күн бұрын
Ply send alternater brush less wireing diagram
@tabtech7249
@tabtech7249 8 жыл бұрын
where is capacitor in Loncin 9600 series i wont found and aftwr turning on nO powet supply what to do??
@Generatorguru
@Generatorguru 8 жыл бұрын
Usually, they are in the Alternator end casing. If not check behind the control panel. :)
@lutherhaith
@lutherhaith 7 жыл бұрын
I have a Vortex SE7200LX gas generator trying to find out who make it so i can buy parts
@Generatorguru
@Generatorguru 7 жыл бұрын
Send us a picture and we would be happy to identify it for you. See link :) www.generatorguru.com/ask-the-guru/
@zeemixvideos6485
@zeemixvideos6485 4 жыл бұрын
can we rewind the alternater
@engineeringdept.generatorg1760
@engineeringdept.generatorg1760 4 жыл бұрын
I would suggest taking this to your local rewind company that will be able to asses if this is viable.
@clist9406
@clist9406 3 жыл бұрын
I would not recommend pulling off the capacitor until you discharge at first it will shock the FaJesus out of you
@phoenixs0und
@phoenixs0und 7 жыл бұрын
I have 10v coming out of the output and 10v at the capacitor tails with the cap disconnected, the cap is 10uf and I put a 100uf just to see if there was any difference but the output was the same please help
@Generatorguru
@Generatorguru 7 жыл бұрын
You need to get a 10uf generator capacitor to replace it. The 100uf will not excite the windings correctly so will not sustain the output (and could damage the alternator!) so this is not a reliable test. (Also if you have run the tests soon after this 100uf capacitor was used it might give false test readings.) Do you have a voltage switch on your generator? If so and you did not before, please set to lowest volt AC and redo the test. Not having it on the lowest VAC setting will give false results. If you do not have this switch on your unit please let us know so we can advise. We will also need to know which generator you have. :)
@phoenixs0und
@phoenixs0und 7 жыл бұрын
Generator Guru I got a 10uf cap and now it's working nicely thanks for your help. only a minor problem now when I take the choke off the engine revs up and down,probably dirty carbon/air filter it runs fine with half choke.
@engineeringdept.generatorg1760
@engineeringdept.generatorg1760 7 жыл бұрын
Dear Sir This would be down to the carb, a good carb clean should have this back to smooth running
@Generatorguru
@Generatorguru 7 жыл бұрын
The engine can be surging due to one of the following: 1. The Spring over the Governor Rod (thin rod from the Governor Arm on the engine to the top of the carb) is loose or become unhooked allowing the engine to surge. (Replace if loose fitting) 2.Lack of fuel to the carb. (remove fuel line from carb and open to see if good fuel flow. Check the state of fuel. If brown or dirty, remove Petcock, rinse tank with new fuel and clean filter above Fuel Valve Petcock.Fill with new clean fuel.) 3. Dirty fuel has blocked up carb jets. (Drain fuel & replace, then clean or rebuild carb with Carb Kit. When rebuilding the carb be sure the Air Mixture screw (Brass with spring) is set 1.5 turns from tight.) 4. (Less common) Governor Spring is loose (Governor arm to engine. Replace if so.) 5. (Less common) Governor Arm has slipped its position and needs re-positioning. (Please contact us for advice or ask a Small Engine Mechanic to perform the task) 6. (Less common) The Governor needs replacing. This is a full strip down of the engine. If you need any further advice, we are always happy to help. :) www.generatorguru.com/ask-the-guru/
@engineeringdept.generatorg1760
@engineeringdept.generatorg1760 7 жыл бұрын
As your Alternator has failed the tests, you need to contact a local “Motor Rewind Company” to see if they can fix it. These companies can vary in price, so if you have time, it is worth getting a few quotes. This is a much cheaper option than replacing the Alternator as the manufacturer charges over ½ the price of a new Generator and we would still need to get it shipped to you from China. Being so heavy, that would be very expensive and outweighs the economy of a new Alternator.
@Genman510
@Genman510 5 жыл бұрын
I’m getting 10volts AC. When I connect a drill to and pull the trigger I get 98 volts and after a minute it shuts off on low v
@engineeringdept.generatorg1760
@engineeringdept.generatorg1760 5 жыл бұрын
Hi Pete Can you tell us which generator you have?
@Genman510
@Genman510 5 жыл бұрын
Engineering Dept. Generator Guru TI 7000 LXR
@engineeringdept.generatorg1760
@engineeringdept.generatorg1760 5 жыл бұрын
Hi Pete I suspect this is a rotor fault, the magnet is failing so it is needing re-exciting every use. Ideally, you need to contact a local “Motor Rewind Company” to see if they can fix it. These companies can vary in price, so if you have time, it is worth getting a few quotes. This is a much cheaper option than replacing the Alternator as the manufacturer charges over ½ the price of a new Generator and we would still need to get it shipped to you from China. Being so heavy, that would be very expensive and outweighs the economy of a new Alternator.
@tonydoherty3234
@tonydoherty3234 6 жыл бұрын
I am having problem with my cheap China petrol generator .the engine runs perfectly and generates 110v on one plug but when I switch to 230v plug it doesn't go above50 v which for UK region is the power you need to run most appliances .this generator inbrushless so no AVR but has an 18uF black rectangular capacitor 300v 50 Hz type .can anyone help diagnose problem .?I suspect capacitor is faulty but can't find this type online
@engineeringdept.generatorg1760
@engineeringdept.generatorg1760 6 жыл бұрын
Thank you for contact generator guru can I please ask that you forward more information about the make and model of the unit and im sure we can help please make contact From here www.generatorguru.com/need-help/
@isaaccoen-graham8867
@isaaccoen-graham8867 3 жыл бұрын
Can i put avr instead of capacitor
@Generatorguru
@Generatorguru 3 жыл бұрын
No the 2 types of alternator work completely differently. Sorry!
@ritz8339
@ritz8339 Жыл бұрын
can i replace 25a 125v diode with 20a 1000v diode?
@Generatorguru
@Generatorguru Жыл бұрын
No. It will not give out the correct output. If you are unable to find a 25a 125v diode try calling you local motor rewind company, chances are they will have one on the shelf.
@ritz8339
@ritz8339 Жыл бұрын
@@Generatorguru can i buy 2 diodes from u?
@luismartinezquebuenmusicae1100
@luismartinezquebuenmusicae1100 6 жыл бұрын
Hola tengo ploblema con mi generador de 950w el estator genera 6v pero no me da desalida nada de corriente 220
@engineeringdept.generatorg1760
@engineeringdept.generatorg1760 6 жыл бұрын
I have been looking into your inquiry. It will be the Capacitor on your generator has blown. You can find this by removing the fuel tank, and you will see it sitting behind the control panel. It has 2 wires going to it, and is a black box held in by 1 screw/bolt. you can find a replacement here www.generatorguru.com/capacitors/
@shelbystrickland1238
@shelbystrickland1238 6 жыл бұрын
We are at a lose any advice of what could be wrong
@engineeringdept.generatorg1760
@engineeringdept.generatorg1760 6 жыл бұрын
Hi there Can you watch the AVR testing video and perform the stator tests in the video, its much more rare that these stator problems occur in brushless generators but they can occur from time to time
@juggallo42O
@juggallo42O 5 жыл бұрын
I just bought a yamaha ef6600dh anf the staor was burnt and buddy had sent it too be fix by someone and they started too remove said bunt winding so i have no way of know what the the # of wire pre slot . its brushless pos..i think they change the capacitor with worng udf and back feed and overload.. but anyways i know it was 17 gauge soft enamel wire i do this the big line from 1too 18 was 60 wire in the slot but not sure its a 36 slot 1ph 2 poles EI stator .. REASON why i say brushless pos .is if you didnt buy it new it pos in most case becasue of ppl thinking higher udf the better its not really it isnt ...
@engineeringdept.generatorg1760
@engineeringdept.generatorg1760 5 жыл бұрын
Hi there We here of people using the wrong capacitor quite often, you are right, there is a general belief that the higher the rating, the better. I'm not sure exactly which gauge wires are used on the Yamaha models, they change their alternator manufacturers often, its part of the reason we don't list as much for Yamaha models, too many variations within the model numbers
@noeljamieson3851
@noeljamieson3851 5 жыл бұрын
Well done plain and simple and in english lol onya
@thomascarron3983
@thomascarron3983 3 жыл бұрын
You need to do your videos out of the wind, noise is terrible.
@Generatorguru
@Generatorguru 3 жыл бұрын
Yeah, sorry. We did this video about 10 years ago for a quick training video with an advanced camera (built-in mic) on what we thought was a calm day. It seems to be worse on some computers. Please accept our apologies.
@luisnunes5681
@luisnunes5681 3 жыл бұрын
I already bought the capacitor for the generator and I did all the test and still no power
@Generatorguru
@Generatorguru 3 жыл бұрын
Try switching the wires to see if this is the case. If that does not work you will need to flash the alternator (with wires both ways until you find power.) If you still have issues please contact us via our website, and we will ask an engineer to assist you. www.generatorguru.com/need-help/
@arengel
@arengel 4 жыл бұрын
Why i have 300v on the 220v plug?
@engineeringdept.generatorg1760
@engineeringdept.generatorg1760 4 жыл бұрын
Hi there For fault finding or technical advice, feel free to contact us using the link below www.generatorguru.com/need-help/ This will allow our engineers to review your query and give you the best possible advice!
@ravindrakumara.
@ravindrakumara. 5 жыл бұрын
1)Why use capacitor? 2) Without capacitor doesn't generat electricity? 3) hydro generator not use capacitor ?
@Generatorguru
@Generatorguru 5 жыл бұрын
Hi there The generator itself produces a small amount of electricity and the capacitor absorbs that voltage builds it up and then pushes it back through the windings which pushes the output voltage up to the required levels, generally generators will either be built with capacitors (brushless alternators) or AVRs that have the capacitor built-in (brushed alternators)
@ravindrakumara.
@ravindrakumara. 5 жыл бұрын
Thanks 3 questions
@albion2742
@albion2742 7 жыл бұрын
I have a StormCat 700-900 GENERATOR FROM hARBORFREIGHT THAS NOT PUTTING OUT VOLTAGE, i PLUGGED MY cOMPRESSOR INTO IT AND AS IT WAS VERY COLD i THINK IT OVERLOADED SOMETHING IN THE GENERATOR, nOW i CANT GET ANY POWER OUT OF THE GENERATOR . tHE GENERATOR STILL RUNS.Oops sorry about the capitals.
@Generatorguru
@Generatorguru 7 жыл бұрын
You have blown the capacitor. Replace with a new one and you should be up and running. You can buy a new one here: www.generatorguru.com/69831-stormcat/?sort=featured I would suspect you blew the capacitor as you have overloaded it. Anything with a motor will need double the running watts to start the motor. (ie. if it needs 600 watts to run it will need 1200 watts to start the compressor motor. It is a quick surge but will damage your capacitor and possibly the alternator, If you run something to large wattage wise.) Hope this helps!!
@albion2742
@albion2742 7 жыл бұрын
Thanks for the replies, I have ordered a new capacitor expect it tommow.
@toddstricker4575
@toddstricker4575 Жыл бұрын
What if it’s less than 5 volts
@Generatorguru
@Generatorguru Жыл бұрын
We it might need flashing to get the magnetism back into the armature. Follow the steps below: To re-excite your alternator, we suggest you only use this method, as described by our friend DonyBoy7 on KZbin: kzbin.info/www/bejne/oqSxaoZnodqEsKM Run the generator for 20 minutes without load to stabilize the magnetic field in the Alternator. Test with a suitable appliance to make sure the load is stable. If not run this test kzbin.info/www/bejne/qnTCfaWoj8iraZo&lc=Ugz_LkGlRT83z2QTiOV4AaABAg (if you do not have brushes, ignore that step.) Please contact us via the website if you need any further help. :) generatorguru.com,
@xenomorph7299
@xenomorph7299 4 жыл бұрын
My capacitor has tons of rust on one of the nodes
@engineeringdept.generatorg1760
@engineeringdept.generatorg1760 4 жыл бұрын
Hi there For fault finding or technical advice, feel free to contact us using the link below www.generatorguru.com/need-help/ This will allow our engineers to review your query and give you the best possible advice!
@xenomorph7299
@xenomorph7299 4 жыл бұрын
@@engineeringdept.generatorg1760 thanks i messaged you on there
@manuelmendez4654
@manuelmendez4654 2 жыл бұрын
El mio manda más 8.voltios es normal
@Generatorguru
@Generatorguru 2 жыл бұрын
Si se quitó el capcitor, esto es demasiado alto. Lo siento. :(
@cechonemec1
@cechonemec1 2 ай бұрын
well I have 12v
@Generatorguru
@Generatorguru 2 ай бұрын
If you removed the capacitor before testing, this is way to high!!! Best bet is to take it to a motor rewind company so they can fix the armature (rotor) for you. If you need any further advice we can help. Contact us via generatorguru.com/need-help/
@leonwilsoniii
@leonwilsoniii 27 күн бұрын
so... ~ 196 volts AC is really not good then. haha
@Generatorguru
@Generatorguru 25 күн бұрын
Well.. either you forgot to unhook the capacitor or you are plugged into the mains power! ;p Unhook the capacitor and test again please. you should never get that high a voltage without a capacitor fitted and you need to remove it for these tests.
@yezelgaming5474
@yezelgaming5474 8 жыл бұрын
only got 2.5 volt its that bad.
@Generatorguru
@Generatorguru 7 жыл бұрын
Low voltage is ok. If you are not getting any voltage out of the generator replacing the Capacitor and running it for 20 minutes without load should bring it up to 5v naturally and restore the full power. If you are getting some voltage with the current capacitor, suggest you “Flash” your alternator. To re-excite your alternator, we suggest you only use this method, as described by Generac Generators on KZbin: kzbin.info/www/bejne/Y321Z2WpopyIibc Then run the generator for 20 minutes without load to stabilize the magnetic field in the Alternator.Next test with suitable appliance to make sure the load is stable. If not please contact us.
@heraamalia7002
@heraamalia7002 5 жыл бұрын
79. ..
@rudolfes
@rudolfes 2 жыл бұрын
Hi, thank you for your insights! How will you go about testing a AVR circuit itself?
@josemonica3063
@josemonica3063 8 жыл бұрын
Hi, thanks for the video. My name is Jose Monica from Portugal, and I have a very old Honda EX650 generator 220Volt. The condenser is damaged, and I can't find the capacitance of it. Can you help me?
@Generatorguru
@Generatorguru 8 жыл бұрын
+Jose Monica If you contact us, our Engineers they can help you pinpoint the part you need. www.generatorguru.com/ask-the-guru/
Which One Is The Best - From Small To Giant #katebrush #shorts
00:17
🍉😋 #shorts
00:24
Денис Кукояка
Рет қаралды 3 МЛН
Ничего не делаю всё видео 😴
00:33
Miracle
Рет қаралды 693 М.
Reparación generador portatil sin carbones 8 KVA
16:40
Arturo Segura
Рет қаралды 244 М.
Brushless generator not producing any power
3:55
Home in the Earth
Рет қаралды 324 М.
Troy-Bilt Generator Engine Runs Well But Doesn't Put Out Power
46:20
Generator Not Making Power - Testing and Repair
46:36
James Condon
Рет қаралды 349 М.
MI TALLER DE LUIS LUCIO
8:28
Lucio Veraza
Рет қаралды 94 М.
Check out this GRAVITY-Powered Electric GENERATOR!!!
12:34
EL ANGELITO
Рет қаралды 318 М.
INFINITE ENERGY? Build a GENERATOR with 2 MOTORS
10:34
EL ANGELITO
Рет қаралды 2,2 МЛН
Run Capacitor Fundamentals Class
13:57
HVAC School
Рет қаралды 591 М.
Which One Is The Best - From Small To Giant #katebrush #shorts
00:17