I always wanted to find a biomedical channel like this! I have learned a lot from this video and have improved my confidence with these devices. Thanks and greetings from the UK.
@BetterBiomedChannel3 жыл бұрын
Thanks for takimg the time to write me!
@abnbmet3 жыл бұрын
I’m watching this in my living room and keep getting up to look in my kitchen for a Lifepak 20 that is unplugged.
@BetterBiomedChannel3 жыл бұрын
🤣
@notfactoryapproved3 жыл бұрын
Thanks for the review. I have been retired for 6yrs. Soon I will go to MercyShips for 2 months. It's amazing what can be forgotten in 6 yrs. It was very helpful to watch this video.
@BetterBiomedChannel3 жыл бұрын
Thanks for writing!
@kidararo4503 Жыл бұрын
Always great videos! Thanks for making this!
@RameshYadav-xw9hp2 жыл бұрын
Hi I appreciate ur effort for such a nice Educational video,sparing time from ur busy schedule. Keep it up
@rutherwatson39812 жыл бұрын
I just graduated as a biomedical technician I I'm interested in your video.
@angelusmendez50843 жыл бұрын
Excellent ! Thanks 😅
@tvs2108Күн бұрын
Are there any important and practical differences between manufacturers in terms of quality and reliability? Thank you for the great useful content and greetings from Ukraine!
@BetterBiomedChannelКүн бұрын
Servicability and user interface will matter most to you. BC and Rigel are your best options for Europe. Check out BCGROUPSTORE.COM for their different esu analyzers. The 2400H is compatible with the most ESUs: www.bcgroupstore.com/Biomedical-BC_Biomedical_ESU-2400H.aspx
@chamindapradeep38713 жыл бұрын
thank 👍👍 great job
@philpage994211 ай бұрын
Hi - great video, now can you show us the leakage current and what the differences are on Fluke QAs 3 and the 454A - I have two 454a and three RF303's and the readings are well different. Thanks.
@luisricardoramirezgonzalez28592 жыл бұрын
Thanks for the video you help me a lot, can you tell me the characteristics of the resistance used in your cables please?
@Kooh2 жыл бұрын
I appreciate the time and effort in this. Question though, the ValleyLab FT10 has a checklist from the service manual and it directs you to do tests in the test mode, do you run that or do you just do general output testing?
@RameshYadav-xw9hp2 жыл бұрын
Plz help in correcting error 9 in valleylab force 40
@RameshYadav-xw9hp2 жыл бұрын
Plz let us know how to correct error 9 in cut display
@RameshYadav-xw9hp2 жыл бұрын
How to Get and reprogram EEPROM for Valleylab Force 40
@DentalEquipmentRepairChannel3 жыл бұрын
I remember using a Nickle to jump out the REM back in the day. LOL
@angiemorales8296 Жыл бұрын
Is there is an issue for bovie cautery pads/pencil going to used to covidien cautery machine?..tnx
@BetterBiomedChannel Жыл бұрын
The monopolar pencils are usually a standard The return electrodes might be different for the shape of the connector and the split pads indicating pin.
@cr-qk4wd2 жыл бұрын
Could you do a vid on testing and calibrating a force triad with a datrend ESU analyzer. Please?!
@BetterBiomedChannel2 жыл бұрын
Sorry. I do not have a force triad or a datred analyzer
@ryanhellrung87482 жыл бұрын
Hey Justin! I have learned some good stuff specifically with the esu's on this channel. I have gotten to be quite good at performing pm's on these devices. Today, i was testing one like I normally do because we had a ticket for one, and it started to make the analyzer short out and say over temp. I tried another esu to see if it was the analyzer or the device itself and turned out it was the device and not the analyzer. Do you know what could be the possible issue could be? I was thinking of a possible board on the coagulation side? Thank you!
@BetterBiomedChannel2 жыл бұрын
No idea. Unplug and measure continuity / resistance, then internal inspection
@ryanhellrung87482 жыл бұрын
@@BetterBiomedChannel thanks for the reply!
@philpage994211 ай бұрын
Use an Oscilloscope and see what the waveform is doing - I'd guess that youve selected Coag but the generator is outputting a Cut waveform - oh and check the frequency of the waveform as well
@ElijahTucke Жыл бұрын
Hey Justin, have you had to fight with testing a Surgitron 4.0 /120?
@BetterBiomedChannel Жыл бұрын
Not yet!
@karieheiselt6763 жыл бұрын
Thank you for making these educational videos. We need to promote more biomeds today. I do have a comment that needs to be considered and that is Accuracy. With today's modern equipment, more emphases is being placed on the accuracy not only of the medical devices themselves but of the test equipment used to test these medical devices as there is a direct relationship. Several of the ESU's that you demonstrate in your video have requirement's for tolerances to be tested to. For example, the ValleyLab (Covidien, Medtronic) FT-10 requires that REM, Power Output and Leakage tests loads ALL be +/- 1% or better. What are the specs of the various units you are using for testing? 1%, 3% or maybe 5% or more. The next point is, does the test equipment have the testing capabilities to completely test to the manufacturer's requirements which are driven by AAMI and/or IEC requirement's. Just because we have always used certain equipment or we like the buttons on one versus another doesn't make it the right tool for the job. Let's make sure we are taking every consideration into account before we select the most appropriate tool for the job. Thank again for your efforts here on your channel. I hope it leads more biomeds to our field!
@happymeal44063 жыл бұрын
Unrelated but are those HL-90's in the background all due for PM? I've been working on those non stop this month lol
@harryjohnson93273 жыл бұрын
I took over that shop last week. They are still there, not due for PM. Not sure what he was doing with them but this dude collected equipment, been spent the last week fixing and sending it all back to the floor. Those warmers are getting tested next week, they all need to be cleaned out. They are 390s btw, newer model, uses a different connector for the cassette so there are no o-rings to replace
@benjieregalado99073 жыл бұрын
Great job as always 👌. i wish i have ESU analyzer too. but sir what is the accepted tolerance? for the sake of other viewers/technician that conduct tests inhouse and doesn't know. is there any standard tolerance per manufacturer/model of machine or the technician should always base to the international standard or NIST when testing the output of the ESU's?
@BetterBiomedChannel3 жыл бұрын
I try to stay within 10% but many manufacturers allow 20-30%
@RameshYadav-xw9hp2 жыл бұрын
Error 9 is for EEPROM checksum error
@pierrejabbour90986 ай бұрын
Inserting the disposable pencil tip directly into the analyzer active electrode port is not something i would show on camera 😂
@BetterBiomedChannel6 ай бұрын
@@pierrejabbour9098 Technicians have used ESU analyzers like that for decades.
@rutherwatson39812 жыл бұрын
Good morning my Name is Ruther S Watson. I'm New in biomedical engineer field
@BetterBiomedChannel2 жыл бұрын
Hi Ruther! I wish you luck in this fantastic career.
@tamerbotros69433 жыл бұрын
Yes about bovie I started on that in college it is here in my area the manufacturer bovie but in CONMED has ESU and other many brands now lol it is not bovie and I think pronk can do better as I saw your demo on that better than qA S Bla bla fluke complicated process between plugging and then unplug all cords during the test ! Yes need to read and study video resources and go on fluke biomedical training site !! To collect all you need step by step yes it is lill tricky but nothing is hard ! If you love the job hahaha
@el7440 Жыл бұрын
three different forms of DRM for a fukin medical device thats so out of pocket