Shandar Video Bhut kuch Sikh liya Acha kam kiya mere ko help ho geya kuch daut tha clear ho geya
@iqubalahmad32763 жыл бұрын
Such a nyc video I have not seen before about access control !! Really superb
@elvsystemwarrioriqubal65133 жыл бұрын
Thanks!! Plz like and share
@malluverse88302 жыл бұрын
Informative video.. 👍🏻👍🏻
@sunilmadane49732 жыл бұрын
Super sir great Information
@elvsystemwarrioriqubal65132 жыл бұрын
Plz like, subscribe and share
@EluruCopRocksTechSolutions8 ай бұрын
Superb brother good thought May God bless you
@myfinedyoutube4937Ай бұрын
Sir hum honeywell Morley ka ias penal ko access door adepter hai use control modual ko conect karte hain to earth fault dekhta hai aisa q
@sarawansaini6 ай бұрын
Very nice
@thevisible91673 жыл бұрын
Nice video 😍😍
@playernazish34453 жыл бұрын
Nice information
@atifameen61583 жыл бұрын
Great
@MerajKhan-pk9hq2 жыл бұрын
So nice video ☺️👌👌👌
@elvsystemwarrioriqubal65132 жыл бұрын
Plz like, subscribe and share
@sandeepkumar-cw3yy Жыл бұрын
Thank you so much sir 🙏🙏🙏🙏
@elvsystemwarrioriqubal6513 Жыл бұрын
Please subscribe and share
@rasikhrahmani85253 жыл бұрын
Good explaination
@elvsystemwarrioriqubal65133 жыл бұрын
Thanks !! Plz like and share
@ramizfarhan5843 жыл бұрын
🤔🤔🤔 Very informative
@elvsystemwarrioriqubal65133 жыл бұрын
Thanks !! Plz like and share
@tekchand920 Жыл бұрын
Sir is panel me fire panel se connection ka point konsa h
@naushadahmad20243 жыл бұрын
Thanku so much for informative video
@rayazahmad62433 жыл бұрын
Sir, plz explain about other access control hardware
@BilalKhan-mu5oi5 ай бұрын
Very informative video, but next time camera angel aur video pe thoda dhyaan do.....new learner's ke liye thoda confusion hoga.
@raghavamit4681 Жыл бұрын
Nice explain but please suggest push button will work on 90 mtr from acces control on cable 0.75 sqmm
@elvsystemwarrioriqubal6513 Жыл бұрын
Yes it will work
@jayantkumarmangaraj86893 жыл бұрын
informative video, but sir please make a detailed video about access control.
@elvsystemwarrioriqubal65133 жыл бұрын
Sure i will make asap thanks 💐
@jamal60303 жыл бұрын
Ek card sahi reader per kam kaise karega. Sare controller ko ek sath jodne se ek controller me card add krne per sabhi controller read krega kya??
@elvsystemwarrioriqubal65133 жыл бұрын
Haanji ek controller aapka master hoga aur baaki controller slave and totat slave controller master controller ke sath loop hoga with communication cable (RS-485) .Ek card aap software me add karoge toh sare controller pe ek card kaam karega
@Maithil_012 жыл бұрын
@@elvsystemwarrioriqubal6513 sir please access controlar ko Configure kese krte h or Isme jo concetvity krte h cables ki uski color coding ke bare m bta do sir m cctv configure ,fiber Spalaizing, raiser punching and liu pictal pr kam krta hu access ka nhi ata salary increase nhi ho pa rhi sir pls bta do 🙏
@musicmood54072 жыл бұрын
How to integrate with fire alarm system and it's termination?
@elvsystemwarrioriqubal6513 Жыл бұрын
Access control systems secure doors using electric locks and restrict passage through those doors to authorized individuals. In the event of a fire, such a system could potentially limit an individual's ability to safely exit and could also restrict access by fire fighters. For this reason, most municipalities have design rules for access control systems and require a permit for their installation and use. In general, if a building (or suite within a building) has a fire alarm and an access control system, the systems should be integrated so that if the fire alarm is triggered, the access control system will release its locks to allow free entry and exit. Various factors are considered by a municipality in determining whether such an integration is required, including the type of locks used, which doors are secured, if there are alternative doors that would allow egress, and the floor within a building where the tenant is located. When an integration between access control and fire systems is required, several things must occur: A permit must be filed by the access control vendor (usually required anyway) The fire vendor must provide a relay connection and any required programming to support it Someone must provide a 2 conductor wire between the access control system and the fire relay A pre-test must be scheduled, which requires a tech from both the fire and access control vendors. In multi-tenant buildings, these are usually outside of normal business hours. These vendors confirm that a fire alarm will successfully trigger (via the relay) a release of all required locks. A final test must be schedule, which requires a tech from both the fire and access control vendors, as well as an inspector from the local municipality. This, too, is usually performed outside of normal business hours. Infassure includes in access control quotes a line item that covers the permitting expense, as well as our attendance of the pre-test and final. Assuming an integration into the fire system is required, there is and additional that is charged by the fire vendor to provide the relay and to attend the tests. This fee varies widely, depending on the vendor. We have seen this fee range as low as $600 and as high as $1500. We always encourage the fire vendor to bill the responsible party directly (usually tenant or landlord) rather than marking it up and billing it ourselves.
@ompathak16942 жыл бұрын
Sir mechanical vale is field me kam kar sakte hai?
@elvsystemwarrioriqubal65132 жыл бұрын
Haanji, fire suppression, fire flooding and fire sprinkler system me mechanical wale jate hain
@ompathak16942 жыл бұрын
@@elvsystemwarrioriqubal6513 And bms me?
@cv6083 жыл бұрын
Sir your insta link is not working .great practical explanation.keep it up
@elvsystemwarrioriqubal65133 жыл бұрын
Thanks for ur appreciation !! I'll check my insta link and correct it
@roushansharma88232 жыл бұрын
Good job sir,where can I learn every thing about elv system in any institute or somewhere else?? Plz reply sir
@elvsystemwarrioriqubal65132 жыл бұрын
I will teach you guys but I was busy with some work but now I will start making videos. Please subscribe ,like and share so that you will get notifications of my new videos.
@ABDULSALAmPALAKKAD2 жыл бұрын
Sir please can you make public address systems videos
@elvsystemwarrioriqubal65132 жыл бұрын
Sure, I Will make videos on PA system.
@muhammadzubair8486 Жыл бұрын
Do you have diagram?
@nagendrah3932 жыл бұрын
Hello sir ..thks fr makeing the vdo ACP control systems. Sir ek question hai mera ek door hai hamaraek site magnetic lock hota hai aur indicated red hai but hum bina push button se door open hou jaat hai,as normally door kaise open hai waisa bina acess wala ..main kal apko vdo bej det houn apka mail id de do sir..
@elvsystemwarrioriqubal65132 жыл бұрын
Jab aapka gate close hoga toh green 🟢indicator on hona chahiye aur jab aap card reader pe card lagaoge toh aapka power cut ho jayega aur EML ki indicator band ho jayegi
@nurulqamar79132 жыл бұрын
How we can add v2000 controller in access 360 software
@nurulqamar79132 жыл бұрын
Hid v2000
@elvsystemwarrioriqubal65132 жыл бұрын
Plz watch this video till the end you will understand how to add controller.
@SanjayKumar-uj5rl Жыл бұрын
Hello sir
@elvsystemwarrioriqubal6513 Жыл бұрын
Hello 👋
@thevisible91673 жыл бұрын
Iqbal sir please speek English ou don't know Hindi 😁😁
@mimsabry35923 жыл бұрын
Hi sir, English explanation more appreciate.
@elvsystemwarrioriqubal65133 жыл бұрын
I will create English content soon
@techclub39532 жыл бұрын
great..... can i get ur contact
@elvsystemwarrioriqubal65132 жыл бұрын
U can contact me on Instagram or telegram
@Faisal.Siddiqui7862 жыл бұрын
Sir Aap ko bahut knowledge hai sir Aap apna number share kar sakte hai kiya please