No video

Transformer On Load Tap Changer Installation تركيب مغيرات الجهد فى المحولات

  Рет қаралды 15,173

EEEB Electrical Engineers Experience Building

EEEB Electrical Engineers Experience Building

Күн бұрын

ABB Diverter Type On Load Tap Changer Installation procedures
EEB links
• EEEB Website Link
www.eeeb-egy.com
• EEEB Facebook Page Link
/ eeeb.egy
• EEEB LinkedIn Page Link
/ eeeb-egy
• EEEB KZbin Channel link
/ enghanykamel

Пікірлер: 19
@owinookello9358
@owinookello9358 3 жыл бұрын
Hi kamel good work
@EngHanyKamel
@EngHanyKamel 3 жыл бұрын
Hey, thanks
@shahzadaslam3221
@shahzadaslam3221 3 жыл бұрын
& thanks for good video
@EngHanyKamel
@EngHanyKamel 3 жыл бұрын
You are welcome
@shahzadaslam3221
@shahzadaslam3221 3 жыл бұрын
I love to do this job
@EngHanyKamel
@EngHanyKamel 3 жыл бұрын
👏👌
@AKSHAYKUMAR-xx2ed
@AKSHAYKUMAR-xx2ed 3 жыл бұрын
Very Informative Video. I have a question, how is an On Load Tap Changer defined thorough its specifications ? For example a Power Transformer would have Technical Specification in Terms of power ratings in KVA or MVA and Voltages on High Voltage Side and Low Voltage Side as 230/13.2 KV and 24/31/37 MVA . Similarly how do you define an OLTC ? Also is it possible to use same OLTC for a Power Transformer of rating specifications 230/115 KVA and 170/238/300 MVA and another Distribution Transformer of Power Rating 230/13.2 KV and 24/31/37 MVA ? If so, would it not be extremely cost inefficient to use same OLTC for a smaller distribution transformer ? Would be optimum ratings (specifications) of OLTC for both type of Transformers mentioned above ? As a student, I would really appreciate if EEEB Team could help me understand these concepts . Thankyou.
@EngHanyKamel
@EngHanyKamel 3 жыл бұрын
Thank you Try to give your suggestions and i will check it so you will learn better
@AKSHAYKUMAR-xx2ed
@AKSHAYKUMAR-xx2ed 3 жыл бұрын
@@EngHanyKamel Thank you for replying to my comment. Looking forward to your reply on the query.
@EngHanyKamel
@EngHanyKamel 3 жыл бұрын
I mean you will try to send suggestions and i will revise it
@AKSHAYKUMAR-xx2ed
@AKSHAYKUMAR-xx2ed 3 жыл бұрын
​@@EngHanyKamel I will try, please correct me where I am wrong. An OLTC should be specified in terms of 1. Highest Voltage Through Equipment , 2. Maximum Rated Through Current and 3. Transformer Power Rating. Accordingly ; OLTC Type 1 (15 kV, 1500 A, Transformer Rating (10 to 100 MVA ) OLTC Type 2 (26.4 kV, 2000 A, Transformer Rating (100 to 200 MVA) OLTC Type 3 (72.5 kV, 2500 A, Transformer Rating (200 to 300 MVA) These should be some methods to define an OLTC. Although I am not sure of the values. For example would it be possible to configure an OLTC Type 1 and would it be suitable for use in Transformer of Power Rating 230/13.2 KV and 24/31/37 MVA ? Or will we need OLTC Type 3 for this type of transformer as well as 230/115 KVA and 170/238/300 MVA Transformer ? What would be the maximum voltages (spec 1) and rated currents through OLTC used in above two transformers ? From what I see in the video OLTC is a significantly large piece of component. Is it possible to fit Oil Immersed Part of an OLTC designed for a 300 MVA Transformer inside the Tank of a 40 MVA Transformer. Or is there significant difference in dimensions of OLTC made for these two type of transformers ? Thankyou.
@EngHanyKamel
@EngHanyKamel 3 жыл бұрын
The tap changer should be installed on the HV side because of lower current and accordingly lower arcing energy for arc interruption during tap changing, so please update
@masimokomakech4204
@masimokomakech4204 4 жыл бұрын
Good info . I work often tapchangers in Uganda . Yo email plse for consultations.
@EngHanyKamel
@EngHanyKamel 4 жыл бұрын
Info@eeeb-egy.com
Transformer Off Circuit and On Load Tap Changer function, components, installation, operation part1
11:38
EEEB Electrical Engineers Experience Building
Рет қаралды 4,1 М.
ABB UZ Tap Changer and Motor Drive Unit Operation and Maintenance part 1
20:27
EEEB Electrical Engineers Experience Building
Рет қаралды 18 М.
Little brothers couldn't stay calm when they noticed a bin lorry #shorts
00:32
Fabiosa Best Lifehacks
Рет қаралды 20 МЛН
Look at two different videos 😁 @karina-kola
00:11
Andrey Grechka
Рет қаралды 15 МЛН
MR VACUTAP® VM®
3:15
ReinhausenTV
Рет қаралды 71 М.
Only 5% of people know about this glue application! Great DIY idea!
14:46
ABB UC Tap Changer and Motor Drive Unit Operation and Maintenance part 1
17:50
EEEB Electrical Engineers Experience Building
Рет қаралды 9 М.
Power Transformer Manufacturing
5:34
electrosnabzh
Рет қаралды 1 МЛН
SIEMENS TRANSFORMERS
5:37
Ashok Dhingra
Рет қаралды 245 М.
Transformer Bushing Manufacturing Process and Testing
6:09
EEEB Electrical Engineers Experience Building
Рет қаралды 10 М.
Make A Teeny-Tiny Model Airplane Engine From Scratch
31:59
JellyFish Machine
Рет қаралды 805 М.
Is it the volts or amps that kill?
20:50
styropyro
Рет қаралды 4,3 МЛН
Installing 3 phase transformer | Starting a Machine Shop 17
12:09
Erik Cortina
Рет қаралды 42 М.
OLTC: On Load Tap Changer. A complete and Practical explanation
6:12