Equalizer Line, Hartford Loop, Wet Return, Drip Line Rough-In on a Steam Boiler Install

  Рет қаралды 9,972

Silent Steam Team

Silent Steam Team

Күн бұрын

Пікірлер: 20
@mjg263
@mjg263 4 жыл бұрын
It’s so awesome to see a well planned piping layout like this that comes from someone with experience! I’ve been watching some of your videos and brushing up on my steam piping basics because a friend of mine is FINALLY having his 1928 converted coal stoker steam boiler replaced this month and I’d like to make sure the contractor gets everything right. I’ve been telling him to replace it for the past 20 some years but he never did, now of course it’s an urgent matter and needs to be done before winter. He knows absolutely zippo about general house related stuff much less specialty stuff like the steam boiler (he keeps calling the damn thing a furnace no matter how many times I tell him it’s a boiler) so I figured I should check in once in a while to make sure it’s getting done the right way. Believe it or not that boiler was still using coal into the 1970’s!
@gordonschweizer5154
@gordonschweizer5154 4 жыл бұрын
I feel so fortunate to receive comments like yours! It lets me know that I am doing some good in the world. I would have like to have seen that coal fired steamer back in the day. Thanks again and happy steaming!
@jamesgillies3710
@jamesgillies3710 4 жыл бұрын
outstanding job great to see a well thought out system.
@worldview730
@worldview730 3 жыл бұрын
Good work and explanation 👍
@gordonschweizer5154
@gordonschweizer5154 3 жыл бұрын
Thank you!
@Vic-kv1rg
@Vic-kv1rg 5 жыл бұрын
Can't wait to see it running, nice work sir
@elgordo271
@elgordo271 5 жыл бұрын
Thank you, sir. Looking forward to posting more progress reports and a final wrap-up soon!
@smartyjones7459
@smartyjones7459 5 жыл бұрын
Old school... I love it... piping by the book... she's gonna make nice dry steam...
@CASTRO45ACP
@CASTRO45ACP 3 жыл бұрын
Probably should've faced that valve handle upwards so it's easier to access
@gordonschweizer5154
@gordonschweizer5154 3 жыл бұрын
Thanks for your comment. In regards to the valve handle replacement, the thought process is that it will be seldom used anyway (still haven't been back since the boiler first fired) and want to reduce the likelyhood that the valve will be shut off by accident. Also, I suppose the handle could be simply removed, the point being is there is no absolute correct answer.
@Vsmechanical_llc
@Vsmechanical_llc 4 жыл бұрын
Hey Gordon beautiful work,did you eve thought in using propress blak fittings for this type of work, Im thinking about of buying propress but I'm afraid of not worthing.
@gordonschweizer5154
@gordonschweizer5154 4 жыл бұрын
I think I'm gonna hold off on using Megapress on steam as a standard for boiler installs. I have concerns about the longevity of the rubber "o" rings they use in general and with steam in particular. That is not to say It never use Megapress. Far from it. I have a set of megapress jaws up to 2" and have used them on gas lines and wet returns and they are a game changer in that regard. And I have used them once on 2-1/2" steam pipe when there was absolutely no other option for repair.
@biker55555
@biker55555 4 жыл бұрын
Happy New Year Gordon! Just wondering, what's the difference between returning the counterflow condensate via the wet return side of the hartford loop vs the equalizer side?
@gordonschweizer5154
@gordonschweizer5154 4 жыл бұрын
I think if you have clean steam and a properly set and operating pressure control, it should make no difference where you put the drip from a counter flow steam main as long as the tie-in is below the lowest safe waterline. I think any issues (water level control, water hammer, etc) that may arise from deviating from "The Book" in the case you are questioning about would generally occur when something else goes out of spec. Even so, I don't want to tempt the steam gods!
@migdaliadiaz8830
@migdaliadiaz8830 2 жыл бұрын
how many days take you to install a boiler
@gordonschweizer5154
@gordonschweizer5154 2 жыл бұрын
For small to medium residentials, about four days, two men.
@bladimygaspard1329
@bladimygaspard1329 5 жыл бұрын
Hi Gordon, I have watched several of videos, and cannot thank you enough for sharing your knowledge. Might I ask whether you have a facebook page or a website in case one would like to reach out to you for consultation?
@elgordo271
@elgordo271 5 жыл бұрын
You are too kind! Thank you. No, I do not have a facebook page or even a website. I do represent my company All Steamed Up, Inc. of Towson, Md. which could be looked up. We are getting slammed with no heat calls, so if you leave a message, please be patient.
@Velez8669
@Velez8669 2 жыл бұрын
Plumbers should not do boiler. SMH
@gordonschweizer5154
@gordonschweizer5154 2 жыл бұрын
*Anyone* who does not read, understand, and follow the instructions that come with *every* boiler should not install boilers.
Steam Heating System Wet Return Multiple Water Leaks Piping Replaces Behind Basement Walls
40:30
Mikey Pipes - Pipe Doctor Plumbing & Heating & Air
Рет қаралды 22 М.
“Don’t stop the chances.”
00:44
ISSEI / いっせい
Рет қаралды 62 МЛН
How to treat Acne💉
00:31
ISSEI / いっせい
Рет қаралды 108 МЛН
Hartford Loop, Equalizer Line, Wet Return Tie-in, & Pressuretrol Oh My!
5:43
steam boiler replacement
25:50
steven lavimoniere
Рет қаралды 53 М.
Weil McLain Steam Vid 3
22:54
grothcc
Рет қаралды 43 М.
Maintaining A Steam Boiler
45:16
The HVAC Hacker
Рет қаралды 89 М.
The Hartford Loop.... What Is It? What Does It Do?
5:35
Silent Steam Team
Рет қаралды 50 М.
Steam Boiler Wiring for Beginners
10:57
Jersey Mike HVAC
Рет қаралды 30 М.
Weil Mclain SGO Steam Boiler Install - Counter Flow Steam Main
6:12
Silent Steam Team
Рет қаралды 7 М.
Steam Boiler Piping Tips
9:33
Heating Help
Рет қаралды 70 М.