The 1 phase Full Converter (Fully controlled Bridge Converter) - Modelling and Analysis with and without Freewheeling Diode
Пікірлер: 6
@suryakumars63583 жыл бұрын
Thanks Really helped me
@shaija3 жыл бұрын
You're welcome!
@onojatestimony30523 жыл бұрын
great video. pls why are we using two different phase delay for the pulse generators
@shaija3 жыл бұрын
Pulse Generators in this model are used to trigger the Thyristor devices. And Th1 and 2 are to be turned on during Positive Half cycle and Th3 and Th4 to be turned on during -ve Half cycle (then only they will be forward biased). As we use a 50Hz supply, T = 20mSec. Positive half cycle - 10mSec, Negative half cycle - 10mSec, So if trigger pulse1 is given at t1=0, trigger pulse2 is to be given at t2=t1 +10mSec. (at a phase delay of 10mSec).
@anastinsasini13413 жыл бұрын
@@shaija how can u say 0.05 sec is 90..is there any formula?
@ABHINAVKRISHNA-iw7fh3 ай бұрын
@@anastinsasini1341one full conduction = 360° Time period =1/f = 1/50= 20ms To find time at 90° (90/360)= (X/20) X= t(@90°)= 5ms