Extension Lead Repair - MK Panel Sockets

  Рет қаралды 11,896

John Ward (jwflame)

John Ward (jwflame)

Күн бұрын

Пікірлер: 74
@Xclub40X
@Xclub40X Жыл бұрын
JW you are the EXTENSION to our lives. . .thank you sir for your great content . . . .
@colinritchie1510
@colinritchie1510 Жыл бұрын
Loved the "blowing away the asbestos dust" comment and also not aligning the screw heads just to annoy people! Brilliant as ever Mr Ward.
@gregf9160
@gregf9160 Жыл бұрын
Nice heavy-duty unit 😀 glad it's salvageable, and has a new lease of life. I would have been _very_ reluctant to have just tossed it away 👍
@tazz1669
@tazz1669 Жыл бұрын
Amazed you found sockets to fit, i wondered how you were going to replace them
@dollarama8652
@dollarama8652 Жыл бұрын
WOW! my neighbor sold his parents house, gave me all sorts of old goodies form the basement... this was one of the things :o
@walseee
@walseee Жыл бұрын
Your voice goes from low to higher pitch every sentence. Great video, it was very entertaining
@lumpyfishgravy
@lumpyfishgravy Жыл бұрын
You're right - that's a dual-branded Fluke-Robin unit, getting on for 20 years old. Good to see it still rocking.
@Mike_5
@Mike_5 Жыл бұрын
Serious cable at 2.5mm ready for heavy duty action - Nice one JW
@andyking8797
@andyking8797 Жыл бұрын
I enjoy watching your videos,. In particular I found your videos explaining lighting circuits uploaded several years ago very informative and useful in helping me extend my lighting circuit to include the loft. Lighting circuits were something I was unsure of and had never tackled before, your explanation on the subject helped enormously. 👍
@andytownsend9163
@andytownsend9163 Жыл бұрын
Love those big wood screws holding the panel on, when im working at dads house everything is screwed in/on with flat head wood screws. Cheers JW 🍻 👍
@Jako1987
@Jako1987 Жыл бұрын
21:14 I call that 90% ruling. If you don't try to do everything perfect you get so much more done. 😎
@pikricky
@pikricky Жыл бұрын
Such a pity an IP65 outdoor socket couldn't have been mounted on there somehow,would have made all the difference to stop water or moisture getting in through the cpc socket,another great video,glad you are back John
@benpatana7664
@benpatana7664 Жыл бұрын
Good job John. Should provide years of further service!
@Petertronic
@Petertronic Жыл бұрын
Nice repair, well worth doing.
@farerse
@farerse Жыл бұрын
I like these repair videos with wiring and tidying up
@shaun30-3-mg9zs
@shaun30-3-mg9zs Жыл бұрын
Nice repair ,looking good .Good work John👍.
@paulf2529
@paulf2529 Жыл бұрын
I think the dust in the cable is actually just humble talcum powder.
@AngDavies
@AngDavies Жыл бұрын
Which, to be fair, is sometimes contaminated with asbestos, particularly industrial grade stuff like that. So probably best not to breathe it in :/
@JasperJanssen
@JasperJanssen 11 күн бұрын
@@AngDaviesshouldn’t be if it was only 20 years old.
@andrewschannel3635
@andrewschannel3635 Жыл бұрын
Disappointed that you blew the asbestos away, I would normally keep it to sprinkle on my dinner.
@farerse
@farerse Жыл бұрын
it's now saturated in the breathing air
@isoguy.
@isoguy. Жыл бұрын
Great tutorial, pleased to see you back..
@HA05GER
@HA05GER Жыл бұрын
You know its old when its got domed flat heads back when stuff was built to last.
@imbenshephard421
@imbenshephard421 Жыл бұрын
No reel surprises here!
@Martin_Martin_Martin_1
@Martin_Martin_Martin_1 Жыл бұрын
I see Watt you did there!
@6A8G
@6A8G Жыл бұрын
Thank you for this John, not only smartened up but safened up also. You didn't feel obliged to strip the '70's orange paint off to give it a 21st-century feel? Nice job sir:)
@richardbrobeck2384
@richardbrobeck2384 Жыл бұрын
Nice repair !
@Saravananmanivel135
@Saravananmanivel135 Жыл бұрын
With love from India
@alanwhite4427
@alanwhite4427 Жыл бұрын
Nice video, keep up the good work 👍
@IC225
@IC225 Жыл бұрын
"asbestos dust found in many cables".....i had to rewind that a few times lol, had me for a few seconds did that.....thatll make amateur DIY folks cry over wiring/re-wiring things up
@skyll4141
@skyll4141 9 ай бұрын
nice job. can you do more setting fire to random faulty electrical items please.
@robputt
@robputt Жыл бұрын
Does the paint on the black panel affect it's CPC arrangements? (I presume it is normally bonded via the screw to the socket if it had bare metal available to contact with)
@jeffeloso
@jeffeloso Жыл бұрын
I agree.
@kevvywevvywoo
@kevvywevvywoo Жыл бұрын
it probably passed the bond tests in the factory as it was and the bean counters decided the seperate earth lead was an unnecessary expense.
@Xclub40X
@Xclub40X Жыл бұрын
This is a REELY good video. . . I hope you all agree
@seanoconnor8843
@seanoconnor8843 Жыл бұрын
I ❤ JW
@markpunt9638
@markpunt9638 Жыл бұрын
Just lubricate the old ones? A squirt of magic spray?
@christopherhulse8385
@christopherhulse8385 Жыл бұрын
At seat socket outlets on trains use these same round MK types.
@paulf2529
@paulf2529 Жыл бұрын
I knew I had seen them somewhere.
@David.R.H
@David.R.H Жыл бұрын
Fascinating
@giz177
@giz177 Жыл бұрын
Any content coming on fault finding for AFDD trips how would you test a circuit for that ?
@jwflame
@jwflame Жыл бұрын
No, because there is no way to test for something that trips an AFDD. An arc fault is only present while the circuit is energised, once switched off it won't be there.
@roberthuntley1090
@roberthuntley1090 Жыл бұрын
OFF TOPIC - John do you know how to submit suggestions for the next UK Wiring Regulations review (and if so could you please forward this on). Thanks in advance. I was looking at an American KZbin video about solar batteries, and in the pre-production phase of development they are working in batteries that take power from a wall socket when charging, and deliver power back to that socket to power the house later on. Technically, this should work AOK, but seems to be a concept that was never considered when the wiring regulations were written. Suggest that the idea needs expert scrutiny when the regulations are next reviewed. I don't believe they ever considered feeding power into a wall socket (and obviously, the device would need some pretty secure interlocks to prevent it powering up the plug pins when away from the socket. PS - They also mentioned that it could be used with a time of use tariff. The concept was it is a portable battery you can take with you when you move house. It looks to be a year or so away from going on sale.
@jwflame
@jwflame Жыл бұрын
Suggestions or corrections should be sent to the IET, details on page 2 of BS7671. What you are describing is a product, which is not covered by the scope of BS7671.
@roberthuntley1090
@roberthuntley1090 Жыл бұрын
@@jwflame Many thanks for coming back so quickly.
@Marcel_Germann
@Marcel_Germann Жыл бұрын
Twin-ferrules will also prevent that the wires come apart over time.
@mernokimuvek
@mernokimuvek Жыл бұрын
I have seen some cheap chinese ferrules which cut a few strands after crimping. When I make something for myself that only I will use I don't bother with ferrules.
@Marcel_Germann
@Marcel_Germann Жыл бұрын
@@mernokimuvek For me it is easy, I purchase ferrules according to DIN 46228. Everything is normalised: -dimensions and tolerances -materials -colour code of collars for the different conductor sizes. kvt-pro.ru/pdf/standarts/din-connection-46228-4-1990-09.pdf
@TestGearJunkie.
@TestGearJunkie. Жыл бұрын
@@mernokimuvek So get decent ferrules. Always use them here.
@suchcone
@suchcone Жыл бұрын
Snazzy shirt!
@ConfidentialMeerkat
@ConfidentialMeerkat Жыл бұрын
Did anyone else hear the high pitch squeal when he turned the rcd on?
@ruben_balea
@ruben_balea Жыл бұрын
That was the beeper on the tester
@TestGearJunkie.
@TestGearJunkie. Жыл бұрын
What, no ferrules..?
@jeffeloso
@jeffeloso Жыл бұрын
Why was the black circular plate not explicitly earthed?
@samuelfellows6923
@samuelfellows6923 Жыл бұрын
Through the socket screws ✅
@jeffeloso
@jeffeloso Жыл бұрын
@@samuelfellows6923 But the paint is insulating the screws. I would have thought a dedicated earthing screw could have been added. The painted wood screws would have been useless for earthing too.
@line10cls
@line10cls Жыл бұрын
Colours on test lead ? to what standard ?
@jwflame
@jwflame Жыл бұрын
All of them
@TestGearJunkie.
@TestGearJunkie. Жыл бұрын
Test leads don't have to adhere to a standard. It's assumed those using them have a clue.
@tarnmonath
@tarnmonath Жыл бұрын
The earth pin does play a part in opening the shutters in MK sockets. The shutters do require that both conducting pins are pushed home at the same time time, but they still remain locked in position until the earth pin has been pushed in. Thus the shutter mechanism is an enhancement on the original BS1363 specification, not an alternative to it.
@temp06j723-pmeighttq
@temp06j723-pmeighttq Жыл бұрын
Really? Then how on earth is 2-pin plugs be possible plugged into these kind of sockets?? (I do see 'grooves' for 2-pin insertion on those LN shutters)
@tarnmonath
@tarnmonath Жыл бұрын
@@temp06j723-pmeighttq Sorry. I wasn't clear. I'm talking about British sockets, which Alec correctly said cannot be used unless the earth pin is inserted first, releasing the shutters.
@jensschroder8214
@jensschroder8214 Жыл бұрын
how do the English make a ring circuit with an extension lead ? In all other countries there are only branches and therefore a maximum of one 15A/16A fuse in the fuse box.
@tazz1669
@tazz1669 Жыл бұрын
There is a fuse rated for the flex in the plug, in this case with the bigger cable it will be 13 amp
@Mark1024MAK
@Mark1024MAK Жыл бұрын
We also have spur circuits that branch off the ring. All our 13A plugs have fuses in them.
@pradolover
@pradolover Жыл бұрын
Asbestos dust 😂 then blowing it away 😅😅😅😅😅
@LoftInsulation-pj9dj
@LoftInsulation-pj9dj Жыл бұрын
Nice video john. However bear in mind that this type AC RCD is still not suitable for drills and vacuum cleaners because most power tools are coming with BLDC motors which work on DC and have some sort of circuitry. This extension lead is obsolete.
@gap9992
@gap9992 Жыл бұрын
Just fit a standard plug then and rely on the RCD in the Consumer Unit?
@_chrisr_
@_chrisr_ Жыл бұрын
You can have both RCDs providing protection - the type AC one may not be effective for certain types of loads where a DC component may be generated but if the installation has a type A RCD upstream then it wouldn't be afffected by the DC current present and so still provide protection. It's worth bearing in mind that many installations in UK will have type AC RCDs only and it is only mandatory for new circuts to have type A fitted so whilst it could be improved upon I wouldn't say it is obselete either .
@drcrusherdata
@drcrusherdata Жыл бұрын
say it's from the 1970's being orange.
@POLITICAL-BIAS.
@POLITICAL-BIAS. Жыл бұрын
Good for another 50 years, I reckon.
@Droningonuk
@Droningonuk Жыл бұрын
Surprised that flex just comes through a metal hole without a grommet
TT Installations
29:20
John Ward (jwflame)
Рет қаралды 58 М.
Newly Refurbished Electrical Shambles
20:50
John Ward (jwflame)
Рет қаралды 168 М.
Когда отец одевает ребёнка @JaySharon
00:16
История одного вокалиста
Рет қаралды 14 МЛН
DID A VAMPIRE BECOME A DOG FOR A HUMAN? 😳😳😳
00:56
НИКИТА ПОДСТАВИЛ ДЖОНИ 😡
01:00
HOOOTDOGS
Рет қаралды 2,2 МЛН
Will A Basketball Boat Hold My Weight?
00:30
MrBeast
Рет қаралды 87 МЛН
EMI Electric Fan Heater Refurbished, Model CRH7
43:20
John Ward (jwflame)
Рет қаралды 38 М.
I tried finding Hidden Gems on AliExpress AGAIN! (Part 11)
15:01
GreatScott!
Рет қаралды 505 М.
Electric Vehicle Charging - Connectors, AC / DC, Home or Away
19:00
John Ward (jwflame)
Рет қаралды 20 М.
Racal-Guardall 1980s PIR Sensor Teardown - Compared with Modern Equivalent
21:40
Diverted Neutral Current - Description Overview Part 1
24:35
John Ward (jwflame)
Рет қаралды 28 М.
Old Electrical Switchgear and Fuseboard
21:20
John Ward (jwflame)
Рет қаралды 15 М.
How Pros Wrap Extension Cords, Cables & Hoses
9:00
LRN2DIY
Рет қаралды 9 МЛН
OFFICIAL | The Best 13 amp double socket on the market. (55)
14:12
J Beck Electrical
Рет қаралды 10 М.
Testing Dangerous Electrical "Life Hacks" from 1911
23:19
Turnah81
Рет қаралды 34 М.
Когда отец одевает ребёнка @JaySharon
00:16
История одного вокалиста
Рет қаралды 14 МЛН