Sos un groso Derrick!!!! Capo total!!! Gracias por compartir tu conocimiento!!!!
@fernandoarielcano42104 ай бұрын
Hace poco empeze a ver tus videos.. la verdad que tus aportes son geniales.. ayudas muchísimo.. muchas gracias por compartir tus experiencia.
@DanielFernandez-fb4sb2 жыл бұрын
Saludos desde uruguay,siempre que podemos vemos tus experiencias para aprender,seria bueno tener un profesor como vos para acá, gracia
@derrickenbuenosaires2 жыл бұрын
Gracias Daniel, saludos a Uruguay
@joseluisdelacruz3210 Жыл бұрын
Buenos días bendiciones para todos muy bueno el video excelente trabajo uste es un maestro
@brattbautistaoscco3229 Жыл бұрын
un maestro enserio perfecta enseñansa en el campo mucha gracias tu experiencia nos sirve a todos gracias por darnos de tu tiempo y tu sabiduria
@guillemartinez82472 жыл бұрын
Tus videos son excelentes,te hace falta una recuperadora de gases para estos trabajos ya que el refrigerante esta muy caro;podes recuperar en un envase todo el refrigerante del sistema podes trabajar tranquilamente. Tu método de trabajo es sobre la marcha donde tu diagnóstico es muy certero se aprende un montón con tus videos y se agradece el aporte.Saludos
@jesusquintero25142 жыл бұрын
Nos vemos en el próximo capítulo jajaja! Éstos equipos son un cuento de nunca acabar pero eso es bueno para nosotros xq así tenemos trabajo y cada vez aprendemos algo nuevo! Saludos desde Ecuador-Venezuela!!!
@luisdiaz58182 ай бұрын
Buenas. No vi que Funcione el forzador del condensador. Tendrá algún sistema de presostato que lo active o sensor por temperatura por qué esto modificaría bastante el comportamiento del funcionamiento e incluso otro parámetro a tener en cuenta es la limpieza del condensador gracias muy útil sus videos.
@enzitoo692 жыл бұрын
Excelente video Derrick, gracias por compartir tus experiencias se agradece! Sigo esperando que algún día hagas otro vídeo explicativo, como fue el de válvulas de expansión pero sobre sobrecalentamiento y subenfriamiento un abrazo!
@ricardoconil15432 жыл бұрын
Gracias .Derrick , muy bueno gracias x compartir tus conocimientos , saludos desde monte caseros corrientes
@manueldiez29292 жыл бұрын
que grande Derrick !! te izo renegar el acmar !!😵 a mí tmb me pasó con una válvula con el bulbo cortado se cerraba y no entendía ni @ !! hasta que me di cuenta pasa que esas fayas no son comunes por eso es bueno lo que ases de repasar los problemas para no olvidar !!! saludos colega !!! si tenés paste algún vídeo de cómo es las reparaciones en usa !! gracias
@carlospalacios34202 жыл бұрын
Excelente explicasión y un buen trabajo amigo Dios te bendiga por tus enseñanzas
@Joseaguilar-pt4iq10 ай бұрын
ERES CHINGON PERO SOLO TE CONFUNDES!!
@derrickenbuenosaires10 ай бұрын
Gracias Weiii !
@federicovarela10382 жыл бұрын
Muy buenos tus videos Derrick, felicitaciones y seguí trayendo tus Derrickaventuras
@juliosan21772 жыл бұрын
Muy bien Derrick , otro cliente satisfecho
@andrewmartinez84595 ай бұрын
Ami personalmente me volvió loco un equipo , no abría la termostatica o válvula de expansión, también tenía falla en el selenoide de líquido ingreso a la válvula de expansión, y problema resuelto.
@waltherherrera672 жыл бұрын
Excelente adelante y éxitos dios te guarde y bendiga
@electronicawalterАй бұрын
Hola exelente video, reparo tambien equipos industriales, y me gusta ver gente que anlizan antes de actuar, me encantan esas mangueeras, son compradas en argentina? un abrazo
@ottoa.menendez171 Жыл бұрын
Excelentes videos aprende mucho de todo, muchísimas gracias
@willyfrias73302 жыл бұрын
Buen video instructivo derrick para aprender algo más 👍👍👍
@victorangel99994 ай бұрын
Gracias por compartir Derrick ..
@alvaropedrozo61172 жыл бұрын
desdes colombia gracias amigo aprendi lo agradezco mucho por recordarme este chicharron
@SergioRaulTañoLazo Жыл бұрын
Amigo Derrick,soy un seguidor de tus videos ,que para mi son " muy didácticos.Me gustaria poder hacerte consultas.Un saludo desde Cuba.
@pablopescetti5136 Жыл бұрын
Q buena explicacion deloq se leiso al eqipo y su problema...
@monguelo2 жыл бұрын
Buenas Derrick, gracias por tus conocimientos, ayudan mucho. Por qué pasa eso en las válvulas de expansión? Donde trabajo tengo una deshumectadora y cada año o a veces a los pocos meses toca cambiar la válvula de expansión. La marca que le pongo es danfoss. Los compresores están 24h en funcionamiento todos los días. Podría ser por estar tanto tiempo en funcionamiento? un saludo y gracias!
@tecnifriotequendama94522 жыл бұрын
Muy buenos el video gracias 🙂 Derrick saludos desde Colombia 👍
@fabianesparza64452 жыл бұрын
Saludos desde México como le puedo hacer un cambio de aceite a a una máquina igual no le encuentro el tornillo de dernado
@walteralvarez84962 жыл бұрын
Hola Derrick ,como siempre dando clases y bien claras, asta el próximo video colega ,que sigas bien!!
@cesarblanco79552 жыл бұрын
Que bien cuidas la herramienta, parece recién estrenada. Que importante tener mirilla en la línea de líquido y en buenas condiciones. Sino esta avería muy difícil de ver. ¿Porque no está instalado el tubo compensador de presión.?
@derrickenbuenosaires2 жыл бұрын
Y maso menos intento de mantenerlas limpias. Tengo que hacer una limpieza general de mis herramientas pronto. El VET original no tenia opcion de compensador. Estos evaporadores son grandes y lo deberia tener para compensar la caida de presion a la salida del evaporador
@luisvillasmil54962 жыл бұрын
@@derrickenbuenosaires amigo Derrick una pregunta, qué sucede si a un equipo de congelación de 3hp le coloco una válvula de expansión de 3hp ? Trabaja bien, o hay q colocar una más pequeña? Y cual seria la correcta? Saludos.
@wolgfangruidiaz2782 Жыл бұрын
Derrick saludos yo acostumbro cuando voy a recuperar una carga cierro el el tubo recibidor enciendo la unidad con mi presostato puentiado. Y antes de que llegue bacio .apago la unidad y cierro la linea de liquido .
@carlosdariomartinez12942 жыл бұрын
Hola amigo Derrick! Saludos de Santa Fe. Gracias por tus vídeos me sacan un montón de dudas continuamente! Quería preguntarte dónde puedo conseguir el imán para destrabar las solenoides, cómo el que vos usas, acá en el país. Gracias!
@dragonrojo10452 жыл бұрын
Bien Derrick, siempre se aprende algo
@VictorLopez-qv1fv2 жыл бұрын
Saludos camaradad #1 chingón carnalito.
@joselm6532 жыл бұрын
Perfecto amigo como siempre! Amaizing!!
@roceloi2 жыл бұрын
11:46 cables pegando en las resistencias de desescarche esperando ha hacer corto!
@sterlingarcher462 жыл бұрын
Primero quiero decir me disculpa para hablar inglés. Couple questions came to my head Derrick : Do you need copper flare washers in between the flare nuts and the male flare fitting on the Txv , and if you do but don't have them available then what can you do ? Nylog ? Loctite ? Do clients where you're located accept that you'd recover the charge and replace the solenoid , dryer and Txv at once , or do they only accept the bare bone minimum . And last , do you even have recovery tanks and supply houses take the freon back and recycle it , or is it just old school no recovery ? ( asking cause I know places where there isn't even logistics in place to recover freon even if you wanted to ) Muchas gracias y cheers mate 👍.
@derrickenbuenosaires2 жыл бұрын
Hey sterling, no problem talking in english 👍 I would say that proper installation would be to use copper or some type of nylon flare gasket on the mating surface but honestly down here I have no idea where one would even buy such an accessory since it's not commonly found. Brass against brass does seal though since I've installed the reducer before in a similar situation. I used some errecom "seal up" thread sealant as well, I prefer nylog but no nylog down here. As for recovery goes, the refrigeration supply houses don't accept recovered refrigerant to be recycled. That's why reclaiming here is practically non existent. The customer almost always has to replace the charge if a part fails where the charge can't be pumped down. There are recovery cylinders here but they are mostly owned by supermarket chains and large manufacturers where they may have 100s of kgs of refrigerant or thousands of lbs. We mostly do the minimum to get the equipment running. (at least with my clients) I would've liked to change the solenoid here because I wasn't sure where the restriction was but I'm sure the customer was grateful that I was able to diagnose correctly and not change something that did not fail even though it is old. The drier I couldn't change because the king valve wouldn't shut properly so he got to keep his older drier lol
@sterlingarcher462 жыл бұрын
@@derrickenbuenosaires thank you very much indeed. Yeah so it's pretty much the exact same thing as the other places I was talking about . It appears that only the "developped" countries have the reclaiming process in place , it's a shame because there would be a whole lot of business to be done around it .
@derrickenbuenosaires2 жыл бұрын
@@sterlingarcher46 What I would really like to see down here is some kind of certification to buy and handle refrigerants. Anyone underage, untrained, whoever can walk into a supply house and buy refrigerant. It takes away jobs from the true technicians and it makes us look bad because some random will do a job for half the price, do it wrong, collect money and disappear. Then the customers become weary of the HVAC techs down here. There's no respect for the residential guys. I'm glad I don't do residential regardless lol
@sterlingarcher462 жыл бұрын
@@derrickenbuenosaires Ah man ! 🤦♂️they've put that in place over here in EU it's called the F-Gas license . Without it you can't handle refrigerant, and there's a second category license that you need to buy refrigerant and then you have to annually report what and how much you've bought , used , reclaimed , recycled and so on and so forth . But then again it's only been put in place and finalised in 09 or 2010 , so not so long ago innit .
@carloscolina26382 жыл бұрын
Saludos amigo.!! Disculpa mi ignorancia y se q no viene con el tema pero. Tengo un compresor q trabajaba con r12 pero en vista q está descontinuado el refrigerante r12 le cambié el aceite para r134a y le hice una buena limpieza a las tuberías. Fui a comprar una válvula d expansión para r134a pero no había la necesaria para 1 1/2 T. M ofrecieron una válvula para r12 y m indicaron q sirve para refrigerante r134a.! Mi pregunta es esto posible?? Sirve o no? Lo has hecho? Gracias x tu ayuda d ante mano.!
@derrickenbuenosaires2 жыл бұрын
Hola Carlos, si te va funcionar perfectamente bien la valvula. Cuando reemplazo r12 mayormente utilizo 437A y compro una valvula de 134A. Son todos refrigerantes de baja presion que se pueden intercambiador sin problema despues que hallas cambiado el aceite a POE. Sigue adelante amigo sin preocupacion
@carlosandrade70912 жыл бұрын
TE extrañabamos derrick, el profesor derrick
@eduardpalma6781 Жыл бұрын
Hace poco me pasó algo parecido la unidad condensadora itarcon no apagan por Pug dawn el control apaga el equipo y tiene presostatos de alta y baja tipo pila y apagan por estos controles si se baja más la presión o se sube el presostato se demora.en reponer y hay que activar las selenoides con el iman
@pelatitorial10542 жыл бұрын
Que tal Derrick, pudiste ver la tobera y filtro de la VET? Para saber si la restricción era por falla, suciedad o humedad dentro del sistema... Lastima que no pudiste cambiar el filtro y la solenoide... buen laburo, saludos
@hackpreak2 жыл бұрын
Lo mismo pensé
@elektrotecnico Жыл бұрын
hola como estas? quisiera saber como se llama el instrumento que utilizar para comprobar la bobina del selenoide en el minuto 7:12 gracias
@derrickenbuenosaires Жыл бұрын
"Solenoid checker" o "tester". No he encontrado alguien que lo vende aca en el mercado pero lo puedes conseguir por amazon
@elektrotecnico Жыл бұрын
@@derrickenbuenosairesgracias, muy amable Derrick, saludos !!
@carlosjavierariaspena67663 ай бұрын
Q número de orificio le colocó a la válvula?
@anibalrivera75295 ай бұрын
Porque nunca prendio el fan del condensador? Gracias
@Oscar-zt2di Жыл бұрын
La válvula selenoide probar en ohmios y la válvula de expansión cambiar la tobera ???
@IvanRRubio-cx5zz Жыл бұрын
Hola Derrick, gusto saludarte, soy Iván Rubio de Honduras, te sigo desde ya hace más de un año y he aprendido mucho con tus videos y tutoriales. Que refrigerante me recomiendas para una unidad condensadora de un cuarto frío que actualmente utiliza R-502 ?
@joseluisdelacruz3210 Жыл бұрын
😅😅😅😅😅 ,
@ernestovaldez4952 жыл бұрын
Primer comentario , siempre aprendiendo del maestro !!!
@derrickenbuenosaires2 жыл бұрын
Gracias Ernesto, un abrazo !
@ernestovaldez4952 жыл бұрын
@@derrickenbuenosaires eres un capo, no me pierdo tus videos.. excelente contenido. Gracias por responder!
@escobar20212 жыл бұрын
hola saludos desde españa
@cristiangonzalez193911 ай бұрын
Que pasa si un motor compresor de frío por alrta Sele echar aceite que con secuessia trae
@educastillo3805 Жыл бұрын
excente
@joseluisgonzalezlopez96962 жыл бұрын
exelente video y trabajo
@paracutirimi2 жыл бұрын
Buen trabajo
@jndenisbergeaud32002 жыл бұрын
Hello my friend how are you doing? From New Orleans
@antoniofernandez-v2t29 күн бұрын
aqui no venden ese iman que usastes en la solenoide la aplicacion no me funciona en el cel
@ivanhhss Жыл бұрын
Estimado ese equalizador externo debe ir conectado porque sino no trabajará la válvula correctamente
@kikebiker Жыл бұрын
Super incómodo ese igualador externo o compensador. Es parte de cambiar una valvula
@carolineustaquiocastro8756 Жыл бұрын
como saber el orificio calibrado que lleva la unidad
@manuelbenito2186 Жыл бұрын
Si metes un iman en la solenoide y luego cuando lo tienes la aspiración a 0 bares cierras la lleve de el compresor lo más seguro es que no tengas el problema de tirar tanto gas
@RobertojavierMeichtri-ig5vt Жыл бұрын
Solo un cosejo tendrias que haver anulado el presostato para travajar con el compresor en marcha para guardar el refrijerante
@alejandrocaller4477 Жыл бұрын
Esa falla se produce por la saturación del filtro, afloja la tuerca y sabrás si pasa o no.
@Luis-2124 Жыл бұрын
después del solenoide se podría poner otro filtro
@joseortoneda16492 жыл бұрын
Gracias, gracias
@leoderosario91502 жыл бұрын
Muy bueno Saludos
@derrickenbuenosaires2 жыл бұрын
Gracias Leo, saludos
@jndenisbergeaud32002 жыл бұрын
Que sucede tengo una clienta que me llamo por carro que no enfría correcto ,yo chequeó todas casas están bien, lo que yo viendo fué el ventilador qué tarda 5 a 6 minutos pará arranca ,puedes me dar un idea que sucede?
@derrickenbuenosaires2 жыл бұрын
Es posible que en tu caso tienes un ventilador que cicla por presostato. Eso lo puedes comprobar viendo donde enciende y corta el ventilador con el manifold conectado al lado de alta. Igual deberia encenderse enseguida si hace calor, si no es porque esta muy baja con carga de refrigerante. Si el ventilador tiene una plaqueta puede ser la logica tambien pero es raro que tarde 5 mins para encenderlo. Yo iria a ver si tiene presostato para el ventilador
@jndenisbergeaud32002 жыл бұрын
Gracias mi amigo
@sergioflores76512 жыл бұрын
Hola dereick necesitas un ayudante? Quisiera aprender más... soy d bs as.. tengo herramientas y vehículo.. j😁
@raulhoraciolecce49262 жыл бұрын
Hola derrick! Una pregunta de curioso, tú llevas una ficha de servicio por equipo intervenido por ti?
@yoberrojas581510 ай бұрын
Exelente vídeo
@josemateo5430 Жыл бұрын
Excelente
@victoravalosjavier38262 жыл бұрын
Muy bueno el vídeo pero veo que nunca arrancó los ventiladores de la condensadores
@derrickenbuenosaires2 жыл бұрын
Gracias Victor, ese equipo es condensado por agua. Cuando empieza verano devuelta en esos dias calidos puede llegar a ciclar devuelta. Saludos !
@victoravalosjavier38262 жыл бұрын
@@derrickenbuenosaires ok gracias por sus explicaciones sos el único que sube vídeos de equipo grande. Amii me encanta la refrigeración estudié me recibí y en mismo tiempo libre hago algunos trabajo. Tengo empleo pero mi sueño sería vivir de este ofició qué es tan lindo la refrigeración .Tengo trabajo fijo en una empresa. Pero algún día me gustaría vivir de este ofició qué es tan lindo la refrigeración le mandó un abrazo grande esperó que tenga mucho éxito en todo. Yo quisiera algún día vivir de este ofició y renunciar a mi trabajo.
@cristiancarrondi24602 жыл бұрын
Soy de Rosario Argentina, cuando veo un equipo de esos se lo hago tirar a la basura
@mariogustavomoreno61572 жыл бұрын
Maestro !!!
@fredysantonioospina59329 ай бұрын
Yo cambiaría el filtro y válvula solenoide
@electronicaconrodiiy94476 ай бұрын
El que tengo se apaga después de un rato según está bien ya revisamos todo de repente se apaga
@Walteracon2 жыл бұрын
mira esos cables de la resistencia re quemados haciendo contacto
@derrickenbuenosaires2 жыл бұрын
Hola Walter, no me di cuenta hasta que empeze a editar el video, parece que en 13:04 los movi de donde tocaban 😂😂
@zottagustavo2 жыл бұрын
Maldita llave, siempre hay alguna en mal estado... Si no, era VET, filtro, y a cobrar! 😉 Chinwewencha, tenés un magnetómetro!