Hi, could i connect explosion proof transmitter to barrier? Barrier can drive transmiiter?
@danmartens12824 ай бұрын
Do you have to use a special cable, or is star and Ed 2 wiresh we idled beden fine
@thesilentgamer42102 ай бұрын
Hello, I am aware of IS CALCULATION concept. But for one loop only. Like BARRIER to JB to LT. But I am not sure how would be the process for IS like this case. BARRIER to JB to FIT to FE? How is The cable from FIT for FE considered in calculation? In my case, I have a flow element with its own instrinsic parameter.. then a transmitter with its own instrinsic parameter also.. so Im confuse how consider it in IS calculation?
@markbreislin2206 Жыл бұрын
How do I contact you regarding calculating IS values
@ramosel Жыл бұрын
I'm glad you asked... it would be nice if they would respond.
@thesilentgamer42104 ай бұрын
Hello, I am aware of IS CALCULATION concept. But for one loop only. Like BARRIER to JB to LT. But I am not sure how would be the process for IS like this case. BARRIER to JB to FIT to FE? How is The cable from FIT for FE considered in calculation?
@martinolesen99303 ай бұрын
Hello, i have a question, if one design a field device according to Ex m (encapsulation protection) does this field device still need energy limiting barriers? In other words, can a Ex m certificated field device, for installation in Ex areas, be non intrinsically safe, or will a Ex m certisfyed device always ALSO have to be intrinsically safe approved, and HAVE to use safety barriers? If a Ex m device do not need safety barriers, then what kind of cabling does it have to use, Ex i cabling ot Ex d cabling, or something else?
@salimtahri2437 Жыл бұрын
good morning i would like to know how long the costing of the control unit is ? thank's
@kareemali18119 ай бұрын
and how i contact you to ask you about intrinsically safe circuit design and the entity parameters and voltage drop ,i want to attend IS design course so i need more information please, if it possible
@kareemali18119 ай бұрын
thanks for useful information ,if you have more videos or information about intrinsically safe design please i have certified in Compex ex 01-04 , thanks
@Puliraptor6 ай бұрын
Not really accurate information I would say also a little misleading: "Simple apparatus shall be clearly identifiable by durable labelling." 16.4 Simple apparatus Simple apparatus is independent of the equipment protection level. Simple apparatus shall be clearly identifiable by durable labelling. IEC 60079-14 Labelling for simple apparatus may be by any party, including the manufacturer or installer, and may be by any designation marking or code preferred for the installation such that it is clearly identifiable as simple apparatus. Additional information to assist in the identification of the simple apparatus such as a reference to the instrument loop number may also be marked.