Great video, my main eco 30 (same as the baxi 800) was not producing hot water and central heating didn’t work. I followed all your checks even pulled out the electrode and flat plat heat exchanger. My boiler had no error codes and the tap sign would flash when asking for water and rad symbol would flash when asking for heat. The pump would run and you could hear the diverter do it check on start up. The fan didn’t run. THE ONLY READING INCORRECT ON TESTING WAS THE DHW SENSOR ON THE DIVERTER VALVE WAS READING 500ohm INSTEAD OF 1k ohms !!!!! I replaced the sensor £7.50 and my boiler now works perfectly. without this video I probably of gone with a PCB (£170) or fan pcb (£250). So glad I watched it first. Don’t suppose you fancy doing a video on how to test the fans pulse width modulating function? That’s the only part of the boiler I couldn’t work out how to test.
@warriorsofwarmth Жыл бұрын
thats the best feed back ever, always a DM away
@RoobieRoo2 Жыл бұрын
You could do it with an oscilloscope I reckon. Measure pulse width modulation that is.
@RoobieRoo2 Жыл бұрын
It's always kind of annoyed me how manufacturer engineers can attend and plug in some software and get the lowdown of what's happening when we can't. They can do that, right?
@asdaasda496710 ай бұрын
Hi which sensor was faulty on yours? Was it hot water ntc in the video its 9mins and 40 second into the video? I dont have any error codes but the hot water and ch flashing for demand but won't fire up, pump runs diverter moves but cant hear the fan run
@captainwiffwaff620110 ай бұрын
@@asdaasda4967 yes mate that’s the one right next to the diverter valve measure the ohm and mine was out of wack making the control unit think the water was already hot. Let’s us know if replacing it fixes the problem.
@robbie2awesome Жыл бұрын
fitted three boiler last week, 2 Worcester Bosch 4000's and one Baxi 818 System 2, actually prefer the older 600 and 800's to be honest, they seem I dunno, more sturdy than the new ones. Great vid to help fault finding.
@warriorsofwarmth Жыл бұрын
the new plastic and design seems weak
@RoobieRoo2 Жыл бұрын
@@warriorsofwarmth yes I'd fit a main eco or even a BAXI platinum before the new 800's and 600's
@jameswilson2899 Жыл бұрын
Good Info anyway , thanks for the content.
@sandorukomski147911 ай бұрын
In my case, after replacing the boiler with a baxi 800, the water works when the heating is on, otherwise it does not heat the water. What could it be
@warriorsofwarmth11 ай бұрын
diverter valve
@pasgas12safe58 Жыл бұрын
Thanks J, good video👍
@warriorsofwarmth Жыл бұрын
Thanks
@charlieb8582 Жыл бұрын
Good stuff mate
@warriorsofwarmth Жыл бұрын
Thanks dude, merry xmas
@jameswilson2899 Жыл бұрын
What was the fault.
@warriorsofwarmth Жыл бұрын
There wasn’t one, I used the opportunity to make a video before relatives moved in 🤣