Few plumbers apply this technique to repair PP-R pipes in confined spaces!

  Рет қаралды 326,588

Mr inventor93

Mr inventor93

Күн бұрын

Пікірлер: 118
@jasonsansonetti2069
@jasonsansonetti2069 Жыл бұрын
Turned a $1.37 and 2 mins to complete repair into a $6.00 and 15 minutes less efficient water flow nonsense repair 😮
@Mrinventor93
@Mrinventor93 Жыл бұрын
The repair was very good, the water did not decrease and it was good for me since I spent a little less than the cost of the repair kit, and the job was done in less than 3 minutes.
@RandyModdSteller
@RandyModdSteller Жыл бұрын
​@@Mrinventor93 😂no way It's not even an "actual problem" it's staged
@jorgesalascastaneda5469
@jorgesalascastaneda5469 Ай бұрын
​@@Mrinventor93ya que más dices si no te echas porras tu mimo
@andymartinez767
@andymartinez767 Жыл бұрын
So many joins for such a simple fix, wow, what an exercise
@RoJe-mi5ob
@RoJe-mi5ob Жыл бұрын
Super reparacion asi queria ver yo una dificil como esa bueno entre paréntesis por que ya vi como lo hiciste y quedo muy bien 👍lo felicito.
@Mrinventor93
@Mrinventor93 Жыл бұрын
Muchas gracias RoJe🤝
@RoJe-mi5ob
@RoJe-mi5ob Жыл бұрын
@@Mrinventor93 lo bueno siempre se agradece saludos
@Mrinventor93
@Mrinventor93 Жыл бұрын
@@RoJe-mi5ob saludos cordiales
@wilsoncampoverde5946
@wilsoncampoverde5946 Жыл бұрын
Gracias por ése buen truco de plomeria
@juliolopez289
@juliolopez289 Жыл бұрын
Saludos amigos y yo les diré con todo respeto que esa técnica es más vieja que mi abuelita en bicicleta y efectivamente hace muchísimo yo lo he hecho, saludos desde San Luis Potosí México, a todos los colegas plomeros del mundo.
@Mrinventor93
@Mrinventor93 Жыл бұрын
Saludos cordiales!
@carlosvillamizar6065
@carlosvillamizar6065 Жыл бұрын
No es la reparación adecuada, ya que cada codo de 90° colocado disminuye significativamente la presión del agua... imagínense! Y colocaron cuatro en ése pequeño espacio 😮
@Mrinventor93
@Mrinventor93 Жыл бұрын
No estoy de acuerdo con lo mencionado amigo como comprueba que disminuye significativamente la presión del agua!!!
@carlosvillamizar6065
@carlosvillamizar6065 Жыл бұрын
@@Mrinventor93 es norma en instalación de tuberías, cada pieza de conexión produce una perdida de presión hidráulica y la que más disminuye la carga hidráulica precisamente es el codo de 90°
@CidEmilio47
@CidEmilio47 Жыл бұрын
​@@Mrinventor93 no tuviste minimo educación basica y de física de fluídos bro? Ponte a leer y estudiar un poco, en la arquitectura se trata de usar lo menos posible angulos de 90⁰ por lo mismo.
@maxipineiro397
@maxipineiro397 7 ай бұрын
Q solución le encontras vos a ese problema???
@tumamalavaajeno
@tumamalavaajeno 4 ай бұрын
Si lo solucionó, pero también hay pérdida de presión en el flujo del agua. En lo personal creo que esta técnica se debe de aplicar solo en cada de ya no existir más opciones para colocar un cople para que la tubería quede lo más lineal posible.
@mundocreativopedroolivar4050
@mundocreativopedroolivar4050 Жыл бұрын
Ciertamente la presión se reduce , pero no es significativo al momento de una reparación, obviamente si llenas la casa de estas curvas será un problema, pero para el caso instructivo de una reparación en particular está muy bien. Y es una idea ingeniosa, muy agradecido amigo , felicitaciones
@Mrinventor93
@Mrinventor93 Жыл бұрын
Buen comentario, muchas gracias amigo
@RD88880
@RD88880 3 ай бұрын
Burna solución 👏, gracias
@Mrinventor93
@Mrinventor93 3 ай бұрын
@@RD88880 Saludos ❤️
@franciscocampos2981
@franciscocampos2981 Жыл бұрын
Con una simple conexión rápida y listo
@dongeorge123
@dongeorge123 Жыл бұрын
Ése arreglo/ trabajo son palabras mayores, a pura vista se mira como algo bien hecho.
@Mrinventor93
@Mrinventor93 Жыл бұрын
Muchas gracias, buen día!
@sanafmahmud6742
@sanafmahmud6742 Жыл бұрын
Extra bend will reduce water flow + extra cost
@Mrinventor93
@Mrinventor93 Жыл бұрын
Additional cost, I don't think so since the repair coupling is more expensive than the 4 elbows and how to ensure that the water pressure is reduced!
@LiuDienNuoc2024
@LiuDienNuoc2024 Ай бұрын
Good job
@armandocoronelgarcia9878
@armandocoronelgarcia9878 Жыл бұрын
Si tú haces esa reparación te verás como un princiante por eso existen Coples de rápida reparación y no le quitas precio ni fluides
@hildebrandomontoyaagudelo7705
@hildebrandomontoyaagudelo7705 Жыл бұрын
Así muy fácil y donde le regalan a uno la maquinista calentadora para hacer el trabajo
@dailytricks6161
@dailytricks6161 Жыл бұрын
good job! thank you and your video!
@Mrinventor93
@Mrinventor93 Жыл бұрын
Thank you My friend
@RD88880
@RD88880 3 ай бұрын
Me tocó hacer dos arreglos como ese en casa, perdidas invisibles, y el defecto fueron piezas uñon se partieron, no sé si eran piezas falladas
@romanmartinez3588
@romanmartinez3588 Жыл бұрын
Creo que si fuera tuberia hidraulica o de cpvc , se podrian poner coples, pero como es tubo plus es mas complicado, por eso quedo con mas codos. Buen video. Grax.
@Mrinventor93
@Mrinventor93 Жыл бұрын
Así es mi amigo, PP-R es difícil de calentar para doblar y colocar el cople como lo hacen normalmente con una tubería de PVC o cpvc, gracias amigo!
@rodrigocastel6663
@rodrigocastel6663 Жыл бұрын
Por suerte existe la pieza copla de repacion ppr, lo mismo para cobre y pvc.
@lyubovhavryshkiv6133
@lyubovhavryshkiv6133 Жыл бұрын
Спасибо вам за мастер класс
@Alex-Tips
@Alex-Tips Жыл бұрын
excellent handling when pipes leak in narrow locations
@Mrinventor93
@Mrinventor93 Жыл бұрын
thank you my friend
@pounent
@pounent Жыл бұрын
Al final , sobrecalientas el material posiblemente pierda presión. En esos casos es mejor darle más tiempo de temperatura en un solo extremo, cosa que te de para fusionar . sin volver a calentar
@charlesparr3296
@charlesparr3296 Жыл бұрын
Why make more friction loss in the plumbing??? You can't just make the original straight coupling joint repair??
@squidolly9659
@squidolly9659 Жыл бұрын
Over complicated repair 😮
@mentayflor
@mentayflor 6 ай бұрын
Por que no le pusite un acople?
@jaimepacheco4991
@jaimepacheco4991 Жыл бұрын
Los que dicen que no es adecuado, yo les pregunto, han hecho esas reparaciones, saben hacerlas mejor? Si es así muestren un vídeo.
@marcelocastro6530
@marcelocastro6530 Жыл бұрын
Con dos fusoras se hace ..el resto está perfecto
@isidrocandeleroarias9317
@isidrocandeleroarias9317 Жыл бұрын
Ay otro tipo de métodos no siempre lo más fácil es lo mejor yo ciento que usted no es plomero
@kevinperales1045
@kevinperales1045 Жыл бұрын
Se reduce la precion del agua x cada codo q se pone y la union doble es mucho mejor
@juliogaray7648
@juliogaray7648 2 ай бұрын
Te queda sifon en el caño , disminuye la presión de flujo de agua,
@rafa6282
@rafa6282 Жыл бұрын
Porque ests esa fuga en ese cuadro
@rafa6282
@rafa6282 Жыл бұрын
Que pasaria si tuviera agua ..que la valvula pasara poca agua
@rollerstuyubmorales3286
@rollerstuyubmorales3286 Жыл бұрын
Cómo está bien grave, eso es una super cochinada, para que existe entonces el acople de reparación
@SouthwestD313
@SouthwestD313 Жыл бұрын
Let's put a shitload of flow restriction in for no reason.
@ericj.s.4392
@ericj.s.4392 Жыл бұрын
Now, if it freezes again, it will defenatly pop there! 😅
@mrsports24.7
@mrsports24.7 Жыл бұрын
Thanks for your idea, but it's not good.😢 If it's PP-R, we have better options
@JATTO_YT
@JATTO_YT 23 күн бұрын
Yo comprando poxipol por que las herramientas son muy caras 😂😂😂😂
@zombi00712014
@zombi00712014 Жыл бұрын
you spent more money on the materials than the work you did
@junpantilano1
@junpantilano1 Жыл бұрын
Bawas naman ang pressure ng tubig jan.
@syssolutionsperu
@syssolutionsperu Жыл бұрын
Disculpa mi ignorancia del caso pero podrías brindarme el nombre técnico de las herramienta (Aquella que es calentador de POR-Tubo plus pero difícil que se llame así) y bueno del resto si se los nombres y uso, aunque debo de mencionar porque no me aplicaste silicona en las uniones por fuera para dejar el sistema más impermeable y seguro ante la manipulación del dueño de la vivienda. Saludos
@Mrinventor93
@Mrinventor93 Жыл бұрын
Hola que tal si claro la herramienta usada es una termofusora amigo, y gracias por los tips🙏
@CarlosDaniel-uy6dc
@CarlosDaniel-uy6dc Жыл бұрын
Holis gracias por El video, como se llama la primera herramienta para picar El tubo por favor
@Mrinventor93
@Mrinventor93 Жыл бұрын
@@CarlosDaniel-uy6dc buen día, la herramienta que utilize para cortar el tubo son unas tijeras de corte para tuberías y la otra que use para calentar el tubo es una termofusora amigó
@demivik5812
@demivik5812 Ай бұрын
All the crap from the water will sediment there which eventually will block the flow. Although, this is only viable option in some cases.
@juliocesarrodriguez9199
@juliocesarrodriguez9199 Жыл бұрын
Mal trabajo con una tuerca unión queda perfecto
@johnhinz9257
@johnhinz9257 Жыл бұрын
I would never repair a pipe that way, those extra corners will cause reduced efficiency, increase vibration and speed up other damage from cavitation.
@alejandrocortazar2619
@alejandrocortazar2619 Жыл бұрын
Creo que le falta experiencia ese fisura o grieta o agujero se puede repar sin necesidad de hacer eso
@blonicvazquez217
@blonicvazquez217 2 ай бұрын
Pésima forma de arreglar esa fuga. Aumenta la caída de presión en la tubería, utiliza materiales extra y no es correcta. No se dejen llevar por todo lo que ven en las redes.
@gugatg100
@gugatg100 Жыл бұрын
Seria mais rápido usar uma luva de correr
@memyself6445
@memyself6445 Жыл бұрын
soooo...create more leak points?.. got it lol
@cuentagenerica1431
@cuentagenerica1431 Жыл бұрын
Muchos curvaturas no bueno
@Mrinventor93
@Mrinventor93 Жыл бұрын
Que recomienda en esos casos amigo! consejos🙏
@nerihernandez9457
@nerihernandez9457 Жыл бұрын
Pero ya existen unos tapones de por para eso 😅
@Mrinventor93
@Mrinventor93 Жыл бұрын
Si porsupuesto solo que los tapones se usarían en caso de que la fuga fuera muy pequeño para que el tapón alcance a cubrir
@luisgervasiomerlin6939
@luisgervasiomerlin6939 4 ай бұрын
Te faltaron codos jajajajajahahaha
@bolillomendez2582
@bolillomendez2582 Жыл бұрын
Mucho desperdicio de material 😅
@Mrinventor93
@Mrinventor93 Жыл бұрын
Por qué desperdicio amigo si el cople de reparación es más costoso que los 4 codos y al final será lo mismo, saludos!
@Jawman5070
@Jawman5070 Жыл бұрын
Don’t do this… there are ways to repair this without introducing elbow joints. Many people are highlighting the reduced flow this causes, but also keep in mind the forces applied to the pipes as the water changes directions 3 times… don’t do this.
@allenrogers6557
@allenrogers6557 Жыл бұрын
🤔
@famosohernandez
@famosohernandez Жыл бұрын
Nunca eh visto ese matererial esta muy raro
@Mrinventor93
@Mrinventor93 Жыл бұрын
Es material de PPR amigo, TUBO PLUS
@diegohernan860717
@diegohernan860717 28 күн бұрын
Reducción de presión de agua. Mal termofusionado . 👎
@kevinperales1045
@kevinperales1045 Жыл бұрын
Era mejor la union doble :v
@ansariahmed9752
@ansariahmed9752 Жыл бұрын
10 rupiya ka mcil laga kar kam ho ja ta to faltu itna kharcha q
@renojaasielnunezm.5482
@renojaasielnunezm.5482 Жыл бұрын
Para que tanta vuelta?
@Mrinventor93
@Mrinventor93 Жыл бұрын
La reparación se realizó de esa forma ya que por el espacio un cople normal era imposible meter talvez con cople de reparación seria la otra forma.
@Tr1pl3Thr3T
@Tr1pl3Thr3T Жыл бұрын
Wow, thats a pretty fancy tool. Most unnecessary thing ive ever seen, in relation to plumbing though.
@norbertolopez8279
@norbertolopez8279 Жыл бұрын
De cuarta!!! la fusión no se gira, pesimo!!!!!
@isidrocandeleroarias9317
@isidrocandeleroarias9317 Жыл бұрын
No sirve esa reparación disminuye la presión
@Gsim-cba
@Gsim-cba Жыл бұрын
No se debe calentar por partes y menos dos veces! No es una práctica recomendable
@herberar
@herberar Жыл бұрын
Eso es un insulto a la inteligencia del plomero más básico. Ahi hay que poner una unión doble y mantener la dirección del flujo del agua.
@IsmaelMarastoni
@IsmaelMarastoni 20 күн бұрын
Está mal hecho!!! En la última unión calentaste 7 segundos las piezas, mientras que tenías 4 segundos para unir las que ya estaban calentadas o fusionadas cómo quieras llamarla
@morenomorver763
@morenomorver763 Жыл бұрын
Jajajajajajaja, qué si esa reparación chafa pero ni modos ahora ya cualquiera es plomero
@realistrealist4347
@realistrealist4347 Жыл бұрын
Змеевик бы скрутил и впаял..
@renojaasielnunezm.5482
@renojaasielnunezm.5482 Жыл бұрын
Tan al raz
@EnglishCad
@EnglishCad Жыл бұрын
Complete nonsense repair. As to confined space, hardly look at the size of the work area. If it's a pressure problem put a gate valve in where the water enters the property.You then have control of the flow rate.
@ostadkaar4763
@ostadkaar4763 Жыл бұрын
creative but i didnt like this way
@Mrinventor93
@Mrinventor93 Жыл бұрын
Thanks, what tips do you give for that repair friend!
@sergg8025
@sergg8025 Жыл бұрын
Наделал изгибов и стыков 👎 А в конце ещё и перегрел трубы, вставил кое-как! Не работа, а порнография! 👎👎👎
@joemendiola7345
@joemendiola7345 Жыл бұрын
No bueno
@aldoaguilar2399
@aldoaguilar2399 Жыл бұрын
Eso está mal con cupla se arregla al pedo hacer esa curva.
@Mrinventor93
@Mrinventor93 Жыл бұрын
Por qué está mal!!!
@aldoaguilar2399
@aldoaguilar2399 Жыл бұрын
@@Mrinventor93 osea se puede hacer de otra forma más fácil
@Mrinventor93
@Mrinventor93 Жыл бұрын
@@aldoaguilar2399 a si entiendo esa parte, pero no está mal el trabajo que se pueda reparar de otra forma es diferente, aquí se ahorro un poco $ ya que comparar el precio de los 4 codos con el cople de reparación si hay diferencia fue más económico, y muchas personas comentan que así disminuye la presión del agua en este caso se probó todo y físicamente la presion fue la misma
@eloyelo8245
@eloyelo8245 Жыл бұрын
Trabajo mal hecho, desperdicio de tiempo y recursos.
@gustaborobertovelardes2798
@gustaborobertovelardes2798 Жыл бұрын
Cuánto gastas .de ja de inventar
@omardimas6524
@omardimas6524 Жыл бұрын
Porquerías, mejor 2 tuerca unión y ya 🙄
@marcelocastro6530
@marcelocastro6530 Жыл бұрын
Eso hay que hacerlo con dos fusoras al mismo tiempo. Así se enfría y no sirve
@Mrinventor93
@Mrinventor93 Жыл бұрын
El tiempo alcanza para solo hacerlo con una, la reparación se hizo y quedó muy bien aparte al unir se ve que el calor en las 2 partes aún esta
@vagocabron2031
@vagocabron2031 Жыл бұрын
Jamás hagan esa porquería
@amalavida3640
@amalavida3640 Жыл бұрын
Deformación del tubo, y tantos codos disminuye enorme la fuerza del agua, ( y no soy tu bro para tu respuesta , al calentar y deformar el tubo por dentro pierde fuerza y reduce la salida con la rebana, instalación sucia en todos los aspectos )
@Mrinventor93
@Mrinventor93 Жыл бұрын
Gracias por los consejos señor plomero, buen día!
@rubencadena1373
@rubencadena1373 Жыл бұрын
HICIERON UN VIDEO CON UNA PUNTA Y CON ESO TAPARON LA FUGA PUES ES MUCHO MATERIAL DESPERDICIADO EN CODOS
@Mrinventor93
@Mrinventor93 Жыл бұрын
No entiendo una parte del comentario pero lo que entendí de mucho material desperdiciado no tanto amigo ya que el cople de reparación es más costoso que los 4 codos, o que recomienda en ese tipo de reparaciones!
@rubencadena1373
@rubencadena1373 Жыл бұрын
@@Mrinventor93 gracias por responder pero sacaron en un video una punta con la termofucionadora y le ponían un tapón y ya quedaba gracias por el video
@Mrinventor93
@Mrinventor93 Жыл бұрын
@@rubencadena1373 oh ya entiendo, si amigo el tapón de reparación se usa mucho tambien pero cuando es una reparación que el diámetro de la fuga es menor a la del tapón esto para que alcance a cubrir, en este caso la otra forma sería usar un cople de reparación pero es más costoso que los 4 codos y la final queda igual.
@tadeovillaservin7731
@tadeovillaservin7731 Жыл бұрын
para mí esta muy mal así no bluye el lagu
@Mrinventor93
@Mrinventor93 Жыл бұрын
Por qué se le hace mal! El agua fluyo de manera normal
小丑教训坏蛋 #小丑 #天使 #shorts
00:49
好人小丑
Рет қаралды 54 МЛН
Что-что Мурсдей говорит? 💭 #симбочка #симба #мурсдей
00:19
Tuna 🍣 ​⁠@patrickzeinali ​⁠@ChefRush
00:48
albert_cancook
Рет қаралды 148 МЛН
She made herself an ear of corn from his marmalade candies🌽🌽🌽
00:38
Valja & Maxim Family
Рет қаралды 18 МЛН
4 ERRORES al instalar TUBOPLUS (ppr), que " NO DEBEMOS HACER", (N° 5)...
5:07
Antonio “Jefe68” Gonzalez
Рет қаралды 59 М.
💥Few KNOW this Method to REPAIR PPR PIPES.
11:46
Aquilino Manitas
Рет қаралды 8 М.
94% of People apply Teflon Pipe Tape incorrectly - This is why it leaks!!
3:07
3 minutes! 3 plumbing tricks that can get you out of trouble - PVC
3:01
Mr inventor93
Рет қаралды 2,9 МЛН
小丑教训坏蛋 #小丑 #天使 #shorts
00:49
好人小丑
Рет қаралды 54 МЛН