What about after it cuts out after a while and safety switch not popped
@pescado994 ай бұрын
Could be either of the two thermisters (located on heating element). Try checking their resistance (with power off). It's also useful to check power consumed when dryer cuts out. I use a plug-in power meter for problem solving. Power should be about 1100 watts on first element, and1600-1800 watts with both heating elements. Also give it a solid clean - take the back off (1/4" socket) and blow all the lint out.