Fixing Everything WRONG with My Dust Collector Setup || Static Electricity || PVC Pipe

  Рет қаралды 14,207

Matt Montavon (MMCC_Woodshop)

Matt Montavon (MMCC_Woodshop)

Күн бұрын

Пікірлер: 86
@Megamailh
@Megamailh 7 ай бұрын
Your explanations are second to none, thank you for your focus and clarity
@mmcc_woodshop6288
@mmcc_woodshop6288 7 ай бұрын
Thanks! Glad the video was helpful!
@haidergildred2621
@haidergildred2621 7 ай бұрын
I’m an engineer and have written on esd even was an expert witness in a couple on legal cases related to injury and esd mitigation. I think your solution here is very good. Use of chains for grounding is pretty common. There are ways you can simply ground yourself with a grounding wrist strap. The discharge is due to a difference in potential between you and the static build up on the equipment. A human can themself build up a static charge of up to 35,000v at 3 amps! So it’s not just the static of the system but also you the operator. Anyway great solution to your problem.
@mmcc_woodshop6288
@mmcc_woodshop6288 7 ай бұрын
That makes sense, I’m sure there’s a lot more that goes into it that I’m aware of. I just tried to reason and use logic, haha. Thanks for sharing your input 👍🏻
@clcphoto
@clcphoto 2 жыл бұрын
The chain is a clever idea to get rid of the static build up!
@mmcc_woodshop6288
@mmcc_woodshop6288 2 жыл бұрын
Thanks Christopher! I’ve milled up a few more batches since this video and it seems to be working well so far 👍🏻
@tanyaroyredcar
@tanyaroyredcar Жыл бұрын
it's all a myth.
@timdoll6718
@timdoll6718 10 ай бұрын
Your system is great and Oneida makes fantastic dust collection products. A couple things I would suggest would be to use a shop vac with a simple and inexpensive Dust Deputy VM for your miter saw and other small dust producing tools like sanders and routers,drill presses etc. They need suction more than High CFM. You can also simply use a cardboard box for the jointer chips as this machine simply drops them down the chute. Doing this you could eliminate a lot of piping and elbows which would increase the CFM to the planer. Great video. Thanks
@mmcc_woodshop6288
@mmcc_woodshop6288 10 ай бұрын
Thanks for the input Tim! I agree, the hose to the miter works ‘okay’ at best. (It does capture quite a bit but there’s a lot it misses too). I plan to upgrade this eventually to a Kapex specifically for dust collection, but that’s a great idea in the meantime 👍🏻
@rossen_nikov
@rossen_nikov 2 жыл бұрын
Hello, watched your video and can agree you came to the right conclusion. I would suggest you consider using the wire all the way long of the PVC piping as they act (as you did it before) as a capacitor and buildup charge when the particles fly/rub around/against the walls. As well with an even better result, you can use simple bare wire instead of the bulky chain and leave it on the ground but the best is to install some grounding rod and properly ground the whole system. By the way, have you guessed what is the purpose of the spring in the flexible hoses you use? If you have taught also for discharge you guested right, so you can screw wire along the PVC and connect it to the flexible hose's spring, and so forth.
@mmcc_woodshop6288
@mmcc_woodshop6288 2 жыл бұрын
Appreciate the input Rossen, those are great points - and I’d say they would definitely improve this system!
@markhagstrom2659
@markhagstrom2659 2 жыл бұрын
Thanks to you I now have an affordable plan for my dust collection system!
@mmcc_woodshop6288
@mmcc_woodshop6288 2 жыл бұрын
You’re welcome, thanks for watching Mark!
@krisklugo8321
@krisklugo8321 2 жыл бұрын
Looks good Matt, my mitersaw dust collection consists of a folded piece of cardboard funneled down to a trash can!!😜🤣
@mmcc_woodshop6288
@mmcc_woodshop6288 2 жыл бұрын
😂 thanks Kris! Hey if it works there’s nothing wrong with that!
@matersworkshop6123
@matersworkshop6123 Жыл бұрын
Your video gives me some ideas on how I'll be getting my dust collection system set up
@mmcc_woodshop6288
@mmcc_woodshop6288 Жыл бұрын
Awesome, glad it was helpful! I’m happy with it so far 👍🏻
@Kopsu87
@Kopsu87 Жыл бұрын
The dust explosion thing is real, but it is VERY rare. The conditions for the dust to explode from static spark must be perfect; exactly right size particles at exactly right density etc.. Another danger to cause an explosion is to put a board through the planer/table saw/drum sander with a nail/screw inside. Not only will it damage your blades, but can cause sparks. Nice videos. Subbed
@mmcc_woodshop6288
@mmcc_woodshop6288 Жыл бұрын
That’s what I’ve read as well. Thanks for the input and the feedback!
@tanyaroyredcar
@tanyaroyredcar Жыл бұрын
myth. yes a metallic object, sucked up, could create a spark if striking an impellor, blah blah which could.... smoulder and start a fire. but, the whole lot is not going to explode.
@slamshed
@slamshed 3 ай бұрын
The chain is a neat idea. You would get "better" grounding by using earthed metal pipe rather than plastic, which is totally impractical. Being zapped is a PITA but I would assume that given you're generating the spark on the outside of the dust extraction the risk would be negligible. Probably better to build a meteorite catcher above the shop ;-)
@mmcc_woodshop6288
@mmcc_woodshop6288 3 ай бұрын
Thanks for the feedback! Video on the meteorite catcher coming soon! 😆
@mattcampbell7873
@mattcampbell7873 11 ай бұрын
Nice fix on the Y. One improvement to keep CFM up would be to remove the the flex hose between cyclone and collector. If you can make that solid, they'll be less friction. Nice lil set up though.
@mmcc_woodshop6288
@mmcc_woodshop6288 11 ай бұрын
Thanks for the input! The flex hose makes it really easy to move/wheel the can around when it's time to empty the bin, but I agree that regular straight pipe would likely provide more CFM.
@bobnovak9624
@bobnovak9624 Жыл бұрын
Hey there! I watched both of your videos and the improvements to the 2nd were spot on! It's hard to tell from the angle of the shots but if you have a 90-degree in the corner nearest your DC, I would suggest using two 45 in that corner to ease the curve. Work safe! :)
@mmcc_woodshop6288
@mmcc_woodshop6288 Жыл бұрын
Thanks Bob! I’ll likely replace that 90 eventually! Thanks for the tips and for watching!
@MarcusRefusius
@MarcusRefusius 4 ай бұрын
“I get shocked every time I touch this” Well quit touching that!…lol. But seriously. The chain is a great solution. Those shocks are annoying at best. Cheers.
@mmcc_woodshop6288
@mmcc_woodshop6288 4 ай бұрын
😂😂 Best advice I’ve ever heard!
@Monkey_Snot
@Monkey_Snot Жыл бұрын
I mentioned last video to ground your system and air to your houses ground, like the ground in an outlet, not sure if you actually did this or tried this, but for me it worked with no static.
@mmcc_woodshop6288
@mmcc_woodshop6288 Жыл бұрын
I don't see why that wouldn't work, thanks for the input. I've just been using the chain method as it was the simplest thing I could think of and it's been working well so far.
@richardc4239
@richardc4239 8 ай бұрын
I simply ran a 16g gare wire down to he tubing and exiting at the blower. Then I took that bare wire and attached it to a plug with the +& - plugins removed. Only the ground( attached to the in-tubing wire) is actually inserted into a grounded outlet.
@steinbierz
@steinbierz Жыл бұрын
Obviously for different reasons but when I was getting underway on Navy ships and then later, Coast Guard cutters, tie-down chain was never allowed to act as the ground for helos on the helo pad. A stranded wire (don't remember the gauge but relatively large) was required; anything with links was not considered a reliable ground. This is certainly a different application but just thought I would throw that out there.
@mmcc_woodshop6288
@mmcc_woodshop6288 Жыл бұрын
Very cool input and thanks for sharing 👍🏻 the chain is probably not the ‘best’ solution, but for a small set up just trying to dissipate the static so I don’t get a small shock seems to work okay. I’m sure there’s quite a bit more to it that I don’t thoroughly understand 👍🏻
@mannyfilmsinc
@mannyfilmsinc 4 ай бұрын
If you were to screw the metal clamps on the pvc pipe to one stud, do we still need the chain? great video
@mmcc_woodshop6288
@mmcc_woodshop6288 4 ай бұрын
Assuming the stud was grounded, I would guess that would ground out the entire system - not needing the chain. Interesting idea, I hadn’t thought of that
@mannyfilmsinc
@mannyfilmsinc 4 ай бұрын
@@mmcc_woodshop6288 If it is a metal stud of course...
@marcellemay7721
@marcellemay7721 2 жыл бұрын
If the chain works, then let it fly. Your mileage may vary on a dry winter day with the static discharge, but I wouldn't sweat it too much until you actually have a static problem again. The plumbing for the dust collection setup looks way better now. You lose a lot of flow velocity with the flex pipe. The straighter and smoother you can make those bends in your piping, the better. If you want to get better flow, put as little of that flex hose in as reasonably feasible.
@mmcc_woodshop6288
@mmcc_woodshop6288 2 жыл бұрын
I’m also really happy with this new setup. The chain has worked well so far, so while I’m not sure if it’s technically ‘grounded’, it has seemed to dissipate the static
@gustaveliasson5395
@gustaveliasson5395 Жыл бұрын
​@@mmcc_woodshop6288 Assuming you're still putting dust through the system the same way you did before, it'll still be creating the same static charge as before. And if it's making the same static charge as before, but you're no longer getting shocked, then it's got to mean that the charge is draining out of the system at a decent pace instead of sitting around waiting to zap you. So while an electrician might roll their eyes at your solution because it's not the "proper" way of grounding the system, it's clearly *a* way of grounding the system.
@gustaveliasson5395
@gustaveliasson5395 Жыл бұрын
And yes, flexhose adds a tonne of resistance. Use it sparingly, stick to pipe wherever possible, and avoid sharp bends.
@russellschonmeier9437
@russellschonmeier9437 Жыл бұрын
Thanks for the video. I am just getting ready to install a dust collector when it arrives. I have to ask you however, Why would you use gawdy chain and have it laying loose on the floor when you have at least 2 ground wires sticking out of your walls that you can connect to?
@mmcc_woodshop6288
@mmcc_woodshop6288 Жыл бұрын
Thanks for watching! The wires aren’t hooked up to my breaker box yet, I just had to run all the wire to put the sheet rock up first. I just haven’t had time to mess with the electric yet, that would definitely work though 👍🏻
@SHarris64
@SHarris64 Жыл бұрын
So… I watched this video quite awhile back, but it’s been on my mind and I thought I would share some thoughts. Now, I am an electrician and “should” know about the static electricity issue and how to solve it. But I think there may be more to what’s going on than meets the eye. My first thought is this… the wire around the pipe connected to the chassis (ground) of the collector should have worked, but obviously didn’t. Today I think I understand why. One of my other hobbies includes antique radio repair. One of the first things you do with an old radio is replace the capacitors. That got me thinking… static electricity is a capacitor!! Capacitors are essentially two plates with different charges separated by an insulator or electrolyte. Capacitance relies on a few things, the size of the plates, the electrolyte, the insulator, the voltage and the amount of charge present. So… hear me out… the wire should have worked, but the wire is a relatively small plate (area) as compared to the pipe and therefore wasn’t able to dissipate the charge. The chain however, is making contact with the concrete floor which is a MUCH larger plate size compared to the pipe and I think this is why the charge was able to be dissipated as it was distributed over a large area and the charge existing at any single point would be very small and wouldn’t be noticed by anyone touching it. I’m probably not 100% correct or explaining it correctly, but I think this is the crux of what is going on. 🙂 Now I can sleep… lol 😂
@mmcc_woodshop6288
@mmcc_woodshop6288 Жыл бұрын
Thanks for the reply and input, that makes sense. I definitely don’t have the best understanding of electricity. I just figured since I was getting shocked that I was becoming the conductor. If I could replace myself with a different conductor (the chain) it should solve the issue. So far it’s worked very well 👍🏻
@gregsnewyt
@gregsnewyt 6 ай бұрын
Eliminate the flex hose by the collector to improve performance. The turbulence created by flex hose dramatically lowers airflow.
@mmcc_woodshop6288
@mmcc_woodshop6288 6 ай бұрын
Good point, thanks for sharing 👍🏻
@jorgfellinger8004
@jorgfellinger8004 2 жыл бұрын
Would be better to straighten the last tube from oneida to the extraction to get more sucction?
@mmcc_woodshop6288
@mmcc_woodshop6288 2 жыл бұрын
Possibly so, I’ll have to try that out and see!
@rwhite9994
@rwhite9994 2 жыл бұрын
Just connect the wire to that green wire right behind the dust collector in the un finished outlet. I use a Computer plug and cut the hot out and use it plug in.
@mmcc_woodshop6288
@mmcc_woodshop6288 Жыл бұрын
That's a great tip! I don't have those unfinished outlets wired to the main electrical panel yet otherwise I would!
@mikemaldag32
@mikemaldag32 2 жыл бұрын
Thanks for sharing , now I think I might use pvc pipe in my future shop instead of metal ductwork since that’s extremely expensive….
@mmcc_woodshop6288
@mmcc_woodshop6288 2 жыл бұрын
That’s the reason I went with PVC!
@BubbasDad
@BubbasDad 2 жыл бұрын
You might want to talk to an electrician, or someone who is familiar with electrical work, to get a real understanding of what grounding means. Just touching the ground with your chain is not grounding. Also it would probably be a good idea to complete the electrical outlets in the walls.
@mmcc_woodshop6288
@mmcc_woodshop6288 2 жыл бұрын
Thanks for the input James! I definitely could benefit from learning from an electrician. The unfinished outlets are now yet hooked up to my breaker box, so no risk there.. nice eye though!
@alexanderturl
@alexanderturl 2 жыл бұрын
Grounding pvc does next to nothing. There is a great video by an electrician explaining why.
@killawee118
@killawee118 8 ай бұрын
He doesn’t need an electrician. He dissipated the static charge in the video. This isn’t an Electrical grounding issue. This is just the dissipation of static electricity.
@alanmatthews9260
@alanmatthews9260 Жыл бұрын
I just watched the video yesterday of a guy who is an electrician by trade and talk about PVC and static electricity and he swears there’s no way to remove static from PVC pipe. And he demonstrated it.
@mmcc_woodshop6288
@mmcc_woodshop6288 Жыл бұрын
It’s certainly an interesting topic without an easy solution 👍🏻
@preformancemustang
@preformancemustang Жыл бұрын
Blast gates can fit in the pvc fitting and held with a screw
@mmcc_woodshop6288
@mmcc_woodshop6288 Жыл бұрын
Thanks for the input!
@TrixyLixyStix
@TrixyLixyStix Жыл бұрын
Hi, just a small comment, can you not put the gate things into the pvc pipe rather than have them in the flexible hose? It might make it look even more neat?
@mmcc_woodshop6288
@mmcc_woodshop6288 Жыл бұрын
They’re a bit too small of diameter. Looking back now I would’ve wrapped tape around the neck of them a few times, putting hose around the PVC was frustrating as it didn’t fit well
@rwhite9994
@rwhite9994 2 жыл бұрын
You would still need to ground the chain, just laying on the ground may not be enough with heavy and long usage.
@mmcc_woodshop6288
@mmcc_woodshop6288 Жыл бұрын
Thanks for the input Ron! I've been using this for a few weeks now and it seems to be working well thus far.
@RayRosher
@RayRosher 2 жыл бұрын
you will get much better air volume if you remove the 90dg bends as the most severe bend you should have is 45dg i would consider a 45dg then a short straight and then another 45dg bend 6that way it will help the airflow
@mmcc_woodshop6288
@mmcc_woodshop6288 2 жыл бұрын
Great tips Ray! I’ll go that route if I ever have to make changes!
@beanMosheen
@beanMosheen Жыл бұрын
The frame of the DC is 100% grounded to the ground rod of your main panel via the ground prong. The reason you copper wire didn't work is because you needed to wrap way more copper. At least four raps per foot. Ground that to the DC bolt and it will work. I bond the wire inside my hoses to that same bolt and it's night and day. The 735 I have will zap the piss out of you otherwise!
@mmcc_woodshop6288
@mmcc_woodshop6288 Жыл бұрын
That makes sense! Thanks for the input!
@MB-wq1hm
@MB-wq1hm Жыл бұрын
You have to run the grounding wire All the way to the out let box, connect it to the conduit. The chain idea is kinda silly.
@mmcc_woodshop6288
@mmcc_woodshop6288 Жыл бұрын
👍🏻👍🏻
@jbaker7903
@jbaker7903 8 ай бұрын
Ground it to the water pipes or to an actual ground rod
@mmcc_woodshop6288
@mmcc_woodshop6288 8 ай бұрын
Thanks for the input and tips!
@allenrussell8816
@allenrussell8816 2 жыл бұрын
you fixed alot of problems with you cyclone but you still have a bunch to go
@mmcc_woodshop6288
@mmcc_woodshop6288 2 жыл бұрын
Have to leave some room for improvement, right?!
@bradleytuckwell4881
@bradleytuckwell4881 2 жыл бұрын
💯 better
@mmcc_woodshop6288
@mmcc_woodshop6288 2 жыл бұрын
Thanks Bradley! I’m much happier with it now!
@donaldhazelberg6678
@donaldhazelberg6678 5 ай бұрын
Why didn't you just use that copper wire you tried to use to begin with?
@mmcc_woodshop6288
@mmcc_woodshop6288 5 ай бұрын
That was the game plan, I don’t know too much about static/electricity so I don’t have a clear answer to that 😆
@grega-kendalheightsdecorwo9511
@grega-kendalheightsdecorwo9511 2 жыл бұрын
Do yourself a favor and get metal blast gates. The plastic ones are a pain over time.
@mmcc_woodshop6288
@mmcc_woodshop6288 2 жыл бұрын
Great point Greg! I’ll likely upgrade them eventually.. I already had the plastic ones so I just went with it for now 👍🏻
@gregsnewyt
@gregsnewyt 6 ай бұрын
You cannot ground PVC, it is the insulator used to surround all your wires. You want to discharge the static electricity with a static discharge device or path. All the screws through the PVC to collect internal static is misinformed BS. Also there has never been a reported dust explosion in a home hobbyist shop. Only a large industrial shop is capable of producing the vast quantities of dust required to reach the threshold of ignition. I used aluminum duct sealing tape on the exterior of the PVC to a ground to discharge any built up static which stopped the static shocks when making contact with the system. Cost is about $4.00 for a roll of tape.
@mmcc_woodshop6288
@mmcc_woodshop6288 6 ай бұрын
Thanks for the input and sharing!
@cjsawinski
@cjsawinski 8 ай бұрын
1:44…. Man you just way over thought how to fix this problem! Lmao… you have the Y on flex hose on both sides, just turn the Y around and let the flex bend in the direction it needs to! Facepalm lol. Sorry not trying to be harsh haha
@mmcc_woodshop6288
@mmcc_woodshop6288 8 ай бұрын
I tend to overthink things haha. I’ve ended up completely redoing the setup again, you might be able to see it in the background of some of my newer videos 👍🏻
@joec5788
@joec5788 2 жыл бұрын
Maybe you should have spent more time getting a clue about what you are doing to start with! You have completely over complicated dust collection and simple grounding, BUT, you did the most important thing that most people will not understand….you, sir, TRIED!!! You did not stop at “I don’t know”. You did SOMETHING where others would have done nothing. You did it, and you put it out there for criticism, considered suggestions and made improvements. Do not stop now young man, always keep critiquing yourself, educating yourself and never quitting short of perfection. Also, keep in mind that perfection is an ever evolving target.
@mmcc_woodshop6288
@mmcc_woodshop6288 2 жыл бұрын
Thanks Joe! Words of wisdom right there. I definitely have to learn the hard way sometimes haha.. no intent of slowing down here!
Dust Collector   Grounding the System
17:42
downtoearthwoodworks
Рет қаралды 182 М.
Making An Automatic Dust Collection System; Shopmade #081
13:34
Jeremy Fielding
Рет қаралды 581 М.
Watermelon magic box! #shorts by Leisi Crazy
00:20
Leisi Crazy
Рет қаралды 106 МЛН
Миллионер | 1 - серия
34:31
Million Show
Рет қаралды 2,6 МЛН
Which One Is The Best - From Small To Giant #katebrush #shorts
00:17
4in, PVC Dust Collection Upgrade | Much Better!
16:14
Northwest Craftsman
Рет қаралды 183 М.
11 common workshop dust collection mistakes
17:26
Stumpy Nubs (James Hamilton)
Рет қаралды 1,3 МЛН
Hack My Shop - 5hp Dust Collector Install
9:56
Jamie Gilgen | Cadence Furniture
Рет қаралды 8 М.
Dust collection adapters shop vac to PVC made fast on the table saw
10:18
Slow and Expensive
Рет қаралды 1,2 МЛН
Harbor Freight 2HP Dust Collector Modification Overview
13:21
Matt Heere
Рет қаралды 402 М.
How to SIZE dust collection pipe! ep18
11:09
Blake Pizzey
Рет қаралды 43 М.
How To Setup A Dust Collection System
12:00
Salt City Workshop
Рет қаралды 25 М.
Building a Tiny Office Pod Under My Stairs
51:47
Man Made
Рет қаралды 3,3 МЛН
Watermelon magic box! #shorts by Leisi Crazy
00:20
Leisi Crazy
Рет қаралды 106 МЛН