FLAME SENSOR FLAME RECTIFICATION. EXPLAINED . TROUBLESHOOTING.

  Рет қаралды 6,779

Alex The Handyman

Alex The Handyman

Күн бұрын

Пікірлер: 32
@mehalainezakarya1496
@mehalainezakarya1496 Ай бұрын
Best video flame rectification explained on KZbin..thanks
@nowavenyone
@nowavenyone 6 ай бұрын
Excellent... Thanks for the perfect explanation
@kevinruggerio1796
@kevinruggerio1796 Жыл бұрын
Nice thorough explanation, thanks for strengthening my weak areas Alex👍
@alexthehandyman3494
@alexthehandyman3494 10 ай бұрын
Thank you so much Kevin. A bit late but good hearing from you. I hope you had an awesome thanksgiving day!
@ryanmcananey6245
@ryanmcananey6245 10 ай бұрын
Wow… that was an amazing vide… very very informative
@alexthehandyman3494
@alexthehandyman3494 10 ай бұрын
Thank you so much!!!
@seshachary5580
@seshachary5580 7 ай бұрын
very educative. Thank you regards
@alexthehandyman3494
@alexthehandyman3494 7 ай бұрын
Thank you so much. Please don't forget to like and subscribe .
@galote0604
@galote0604 9 ай бұрын
Very very good job 👏 your email 📧 thank you so much for your help!!!
@claudioaguilera2947
@claudioaguilera2947 10 ай бұрын
Thanks Alex
@ElectroVolta
@ElectroVolta Жыл бұрын
Hello. How can you measure current getting the current to earth like in minute 9:29 ???
@alexthehandyman3494
@alexthehandyman3494 Жыл бұрын
Hello
@alexthehandyman3494
@alexthehandyman3494 Жыл бұрын
Hello. Set your meter to micro amps. Put one lead on ground, place the other meter lead on the rod (without removing the power source to the rod )
@JesicaM.
@JesicaM. 10 ай бұрын
I have a question about the flame sensor I have the same issue going on with my unit I wanted to know if it's dangerous to let it run like that?
@alexthehandyman3494
@alexthehandyman3494 10 ай бұрын
Hello Jessica, thanks for your question. The flame sensor would turn the unit off if the flame is missing or something wrong with the flame. That is a safety. Please expand on the problem you have . Be specific. Thanks
@JesicaM.
@JesicaM. 10 ай бұрын
@@alexthehandyman3494 the problem is that the the fan turns on then the flame turns on for a couple seconds then it turns off then back on I wanted to know if it's dangerous to let it run that way
@alexthehandyman3494
@alexthehandyman3494 10 ай бұрын
So obviously there is something wrong with the furnace . The flame sensor is doing what is suppose to do . Please have a professional fix the furnace. Better yet, why don't you clean the flame sensor is super easy. The problem might be something else but at least try. I might get you through the night but fix it soon.
@JesicaM.
@JesicaM. 10 ай бұрын
@@alexthehandyman3494 song My question is do you recommend me to leave the furnace unit off until it's fixed buy a professional I don't have no one that can do that for me the only option I have is to call a professional to come and clean it out but thank you so much I really appreciate for that information I will follow you
@alexthehandyman3494
@alexthehandyman3494 10 ай бұрын
@@JesicaM. Hello Jessica. How are you ? How is your furnace doing ?
@AlexDeutsch-g2x
@AlexDeutsch-g2x 8 ай бұрын
Great video, I was just wondering what happens to the negative sine wave of the AC current after flame rectification turns AC current into pulsating DC current. I understand only the positive sine wave is allowed to pass through the flame but what happens to the negative sine wave? Thanks
@alexthehandyman3494
@alexthehandyman3494 8 ай бұрын
Hello, in a regular AC you have the hot and the neutral wires. The current goes from positive to negative 60 times in a second. (sine wave) In this case in the furnace is just one path. It doesn't return to through a neutral. It dies at the control. That is my take. Im not an expert. Does it make sense?
@AlexDeutsch-g2x
@AlexDeutsch-g2x 8 ай бұрын
Yeah that makes sense, thanks for the response
@vioreltorj
@vioreltorj 10 ай бұрын
Thank you Alex, You did really good explaining.Good instructor 😊
@alexthehandyman3494
@alexthehandyman3494 10 ай бұрын
thank you so much. It means a lot coming form you!! Please don't forget to like it.
@philspargo9543
@philspargo9543 8 ай бұрын
Alex, In minute 13:40, you are talking about microamps... You said : "a microamps is one billion of an amp". A microamp is ONE MILLIONTH of an amp! A microamp IS a microamp! Good video! Thnaks!
@alexthehandyman3494
@alexthehandyman3494 8 ай бұрын
Hey Phil. \Thanks for catching that. You are right! Thanks for your comment
@Elcosmicstar1
@Elcosmicstar1 Жыл бұрын
Hi Alex, you made a mistake, voltage is measured in parallel or acress a device, current is always measured in series because it is measureing the flow of electrons. In order to get a correct measurement, you need to remove the connector off the probe and connect the meter on the microamp scale between the probe and the connector. When you connected the meter in parallel to the probe and ground, you are actually dividing the current between the control board and the probe, so in effect, you are not measuring the current that is going through the probe but instead the current delivered by the control board. If the probe is dirty, the way you did it will make it appeared cleaned and working because you see the microamp reading. Troubleshooting will be much more difficult because someone following your steps would be of the opinion the probe is working. This did not become apparant to you only because you always cleaned your probe as a first step.
@alexthehandyman3494
@alexthehandyman3494 Жыл бұрын
Hello there. You are so right! IN minute 7 52 I meant to read voltage in parallel . One lead was on the female connector and the other should have been on to ground. Not on the sensor as I did. Since the sensor is just a rod and it was cleaned and it was screwed to the metal of the furnace and it was grounded . It gave me the measures I was looking for. even though it did it wrong. Thank you so much for catching that.!!!! Im going to make a correction on the description of the video
@roqueherrera8471
@roqueherrera8471 11 ай бұрын
I use nut driver drills can crack porcelain and vibration can crack the glow igniter too. 👍🏽. U doing fine bud
@alexthehandyman3494
@alexthehandyman3494 11 ай бұрын
valid point. thanks a lot for your input!!@@roqueherrera8471
Flame sensor, Flame rod, Flame Rectification
9:53
Love2HVAC with Ty Branaman
Рет қаралды 55 М.
SHAPALAQ 6 серия / 3 часть #aminkavitaminka #aminak #aminokka #расулшоу
00:59
Аминка Витаминка
Рет қаралды 1,7 МЛН
БЕЛКА СЬЕЛА КОТЕНКА?#cat
00:13
Лайки Like
Рет қаралды 2,2 МЛН
The Joker wanted to stand at the front, but unexpectedly was beaten up by Officer Rabbit
00:12
Furnace Not Working - Troubleshooting the Flame Sensor
17:05
Word of Advice TV
Рет қаралды 343 М.
Flame Sensor Troubleshooting & Install
12:05
HVAC School
Рет қаралды 24 М.
Understanding Furnace Flame Proving Controls
1:02:51
Jackson Systems
Рет қаралды 30 М.
Flame rectification and physics behind it  ( flame based diode )
18:42
High Voltage Engineering by MG Niasar
Рет қаралды 3,5 М.
Furnace Flame Sensor Testing and Flame Rectification Troubleshooting!
11:27
AC Service Tech LLC
Рет қаралды 170 М.
Tech Tuesday with Loy - Flame Rod Applications and Basics
36:42
Loy Instrument
Рет қаралды 2,3 М.
SHAPALAQ 6 серия / 3 часть #aminkavitaminka #aminak #aminokka #расулшоу
00:59
Аминка Витаминка
Рет қаралды 1,7 МЛН