Model IS Air Dryer Functionality

  Рет қаралды 38,842

Fleet Products Ltd.

Fleet Products Ltd.

Күн бұрын

Пікірлер: 55
@waitemc
@waitemc 4 жыл бұрын
Rare for anyone to show a bypass alterantive. Thumbs up
@joshuazimmerman8241
@joshuazimmerman8241 7 ай бұрын
Thanks for this video, solved my problem without paying a shop to figure it out.
@fleetproducts
@fleetproducts 7 ай бұрын
Awesome glad to hear Joshua.👍
@bwwatson16
@bwwatson16 10 ай бұрын
I have had hell with these dryers on 3 different trucks not supplying air to the tanks and air bags. But I have found that backing off the pressure valves on the bottom one turn will allow air to come out of the ports.
@rumplejesusskin
@rumplejesusskin 10 ай бұрын
If we were to install an alcohol evaporator on the air system, it would go after the air dryer correct. But now would we plug the primary and secondary outlets and then take the evaporator exit and split it in 2 lines one to each tank?
@fleetproducts
@fleetproducts 10 ай бұрын
This dryer is really not made for an alcohol evaporator to be installed. You would have to splice the line leaving the dryer tank to the wet tank to avoid alcohol getting in the dryer cartridge and plugging your system.
@tmorales7674
@tmorales7674 Жыл бұрын
I got a question one of those tiny valves opens after the truck is been parked for 30 min or more, do you know what’s causing it??
@fleetproducts
@fleetproducts Жыл бұрын
Sorry for the delay. I am thinking you are talking about one of the 4 pressure protecting valves in the dryer that allows air to be delivered to air tanks and other air components in the truck. it does not make sense that the valve would open after the truck has sat for 30 min’s as these valves need more air pressure to open. the first valve opens at 106 PSI then the other three open by the time you get to 110PSI. If one of the valves was sticking and your air system was over 106PSI, I guess it might open up but you should notice that something is missing air pressure somewhere in your truck. So this might be something to check. Could one valve be sticking and something missing air?
@captnkurt83
@captnkurt83 Жыл бұрын
Just installed a new one, builds to 130 just fine, then turns the compressor on when it gets to 115. Really annoying because that small variance makes it so the compressor is running too much. Can this be fixed?
@fleetproducts
@fleetproducts Жыл бұрын
A 15-20 PSI spread is the industry standard. I suggest that you check for any leaks in the unloader line or purge valve at the dryer. A small leak on the unloader side of the governor will cause the dryer to cycle. This pressure must remain constant. There is a check valve between the governor and the body of the dryer that might be dirty and causing the valve to stick open which would cause the unit to cycle as well. Hope this helps.
@jargsaleen
@jargsaleen 7 ай бұрын
Hello, I have a question. Why does mine returns air through the supply line even when engine off, truck looses all air in less then 30 minutes. Dont see any check valve and no one talks about that. This is my fourth dryer trying to solve the issue.
@fleetproducts
@fleetproducts 7 ай бұрын
There is a check valve under the governor. You have to take the governor off to get to it. It's purpose is to check the air tanks from draining so this should help to solve your issue.
@joec9739
@joec9739 2 жыл бұрын
Hello I have a question about the governor. I replaced mine but with am adjustable version. I notice my compressor now has a harder time to build air. Does this dryer only take non adjustable governors only??
@fleetproducts
@fleetproducts 2 жыл бұрын
You should only use a non-adjustable governor with these dryers. Part # 5004049.
@fleetproducts
@fleetproducts 2 жыл бұрын
Sorry you can use an adjustable governor but you must set it to 130 psi.
@punjabientertainment7518
@punjabientertainment7518 4 жыл бұрын
I would like to buy that bypass valve to keep in my truck. Is there any link or part number on that bypass valve you can give us?
@fleetproducts
@fleetproducts 4 жыл бұрын
You can put the bypass valve together yourself with a tee fitting and a few bushings from your local fitting shop.
@marknegrete9353
@marknegrete9353 2 жыл бұрын
Quick question. Can I eliminate governor on dryer if I have one on compressor? I’ll still run a line to send signal to dryer.
@fleetproducts
@fleetproducts 2 жыл бұрын
Sorry for the delay, you should not remove the governor from the AD-IS dryer as it is an integrated system. I would recommend that you install an AD-9 dryer instead of the AD-IS dryer.
@marknegrete9353
@marknegrete9353 2 жыл бұрын
Thanks for the reply, I was thinking the same thing. I have a tu-flo 550 compressor . I think that one needs a governor as well.
@elchefelmunecotruck9039
@elchefelmunecotruck9039 3 жыл бұрын
Hello thank you for the Vidio what is number side and name for the fitting for the by pass I have the problem one time in Miami and the roads service take out 750 just for chance the air dryer I have the new part other day I have the problem I chance the air dryer but is good to know the by pass Thanks other question for air dryer what is the difference in aftermarket and original gracias
@fleetproducts
@fleetproducts 3 жыл бұрын
Hello, you can put the bypass valve together yourself with a tee fitting and a few bushings from your local fitting shop. In regards to aftermarket vs OEM, they should be like for like but there is different aftermarket quality out there.
@jwgloballogisticsllc1406
@jwgloballogisticsllc1406 2 жыл бұрын
Air pressure to secondary tank builds up great but primary builds super slow… no leaks found, compressor is good. What to do?
@fleetproducts
@fleetproducts 2 жыл бұрын
Were the pressure protection valves adjusted at all? This could be causing the issue.
@jwgloballogisticsllc1406
@jwgloballogisticsllc1406 2 жыл бұрын
@@fleetproducts That’s what I was thinking also… but I’m concerned because they said not to adjust them.?
@fleetproducts
@fleetproducts 2 жыл бұрын
@@jwgloballogisticsllc1406 Yes these pressure protection valves all come pre-set so if they are adjusted in any way, issues will likely arise.
@jwgloballogisticsllc1406
@jwgloballogisticsllc1406 2 жыл бұрын
@@fleetproducts How would I know if they have been adjusted? I bought the air dryer new… but having issues with my air compressor… now this?
@fleetproducts
@fleetproducts 2 жыл бұрын
@@jwgloballogisticsllc1406 You won't be able to tell unless the pressure protection valves have markings on them noting the "set" position. All of the pressure protection valves should be marked in the casting. The issue you are having is with the primary tank so find primary valve and back it off a quarter turn at a time and test it. Keep trying until hopefully it fixes your issue.
@albertodominguez150
@albertodominguez150 2 жыл бұрын
Hello there, my problem it's that the air dryer doesn't refill both tanks and the air compressor it's good
@fleetproducts
@fleetproducts 2 жыл бұрын
There is a port on this dryer for the primary tank and a port for the secondary tank. The pressure protection valves are pre-set so if these have been adjusted, you may have closed off one of the ports to one of your tanks.
@kelvingonzalez2774
@kelvingonzalez2774 3 ай бұрын
Help...I just installed one new but it doesn't sent air out the unload valve and compressor keeps building pressure and nothing
@fleetproducts
@fleetproducts 3 ай бұрын
I would check to make sure that your supply line from the tank to the governor is in the right port. Must be a supply port. Bottom section of the governor.
@kelvingonzalez2774
@kelvingonzalez2774 3 ай бұрын
@fleetproducts the supply line from the tank to governor? I have one line from the tank going into reservoir B on the governor
@kelvingonzalez2774
@kelvingonzalez2774 3 ай бұрын
I got the supply from compressor going into the supply in
@fleetproducts
@fleetproducts 3 ай бұрын
@@kelvingonzalez2774 Perhaps the governor is defective. The governor controls when the compressor pumps and when it shuts off. When you say the dryer unloader is not working are you saying the dryer will not purge? If it will not purge it needs to be told when to purge which comes from the governor. The actual unloader is in the compressor. Please feel free to give us call toll free at 1-877-243-0442 and speak with a technician if you require further info.
@kelvingonzalez2774
@kelvingonzalez2774 3 ай бұрын
@fleetproducts I found the issue, it was the governor
@rig0358
@rig0358 Жыл бұрын
What I have to do with the 4 safe valves if I torn to adjust
@fleetproducts
@fleetproducts Жыл бұрын
We recommend that you do not adjust the pressure protection valves as they all come pre-adjusted.
@chriswyatt432
@chriswyatt432 Жыл бұрын
Can these be rebuilt
@fleetproducts
@fleetproducts Жыл бұрын
Yes they can be rebuilt.
@costinelsaghin9590
@costinelsaghin9590 11 ай бұрын
You don’t took more dips exactly
@davidmichaelis49
@davidmichaelis49 2 жыл бұрын
Where can I get brass pressure protection valves tired of mine getting broken by rocks
@davidmichaelis49
@davidmichaelis49 2 жыл бұрын
Also tired of stealing them out of new air dryers
@fleetproducts
@fleetproducts 2 жыл бұрын
@@davidmichaelis49 Sorry but I am not aware of brass pressure protection valves being offered for this unit.
@davidmichaelis49
@davidmichaelis49 2 жыл бұрын
Where can I get replacement plastic ones
@fleetproducts
@fleetproducts 2 жыл бұрын
@@davidmichaelis49 I would try Bendix for replacements.
@davidmichaelis49
@davidmichaelis49 Жыл бұрын
You guys really need to make the plastic fittings for the pressure protection out of brass because here I am once again sitting on the side of the road because it’s broken
@macho1657
@macho1657 Жыл бұрын
Whats the part number for this Dryer??
@fleetproducts
@fleetproducts Жыл бұрын
There are a few different part #'s but the most common would be 5010133X.
@macho1657
@macho1657 Жыл бұрын
@@fleetproducts thank you...🙏🏼
@chriswyatt432
@chriswyatt432 Жыл бұрын
Anyone know where you can get these dryer rebuilt or exchange
@fleetproducts
@fleetproducts Жыл бұрын
Give our parts department a call at 1-877-243-0442 and they can help you out.
5.11 Air Dryer Operation
6:08
Jim Mack
Рет қаралды 50 М.
How it feels when u walk through first class
00:52
Adam W
Рет қаралды 24 МЛН
Это было очень близко...
00:10
Аришнев
Рет қаралды 6 МЛН
¿Cómo funciona el secador de aire AD-IS? | Frenos de aire
14:05
Camion Auto y Bus
Рет қаралды 48 М.
truck wont build air - - quick fix - -
7:21
Ezrider359
Рет қаралды 444 М.
Air Dryer
5:01
Fleet Products Ltd.
Рет қаралды 255 М.
diy super dry air on the cheap.
8:54
JDS Outdoors
Рет қаралды 19 М.
How to make a Air Compressor After Cooler (low cost)
4:43
Doug Green
Рет қаралды 125 М.
Delair Desiccant Dryer Video
4:15
Delair India
Рет қаралды 127 М.
Air Dryer Replacement. 2014 Kenworth W900L ISX 15 How to.
5:26