Flooding in distillation Column | Symptoms of flooding | What will happen when we increase reflux

  Рет қаралды 18,743

Sandeep Academy [IITR, GATE AIR 1]

Sandeep Academy [IITR, GATE AIR 1]

Күн бұрын

Пікірлер: 44
@im_godspeed
@im_godspeed Жыл бұрын
I'm working in the oil industry for the past 7 years and still I get to learn a lot from you brother. Thanks for making these informative videos
@brandonking4918
@brandonking4918 2 жыл бұрын
Great work sir!!! As always Conceptually explained. I have been following your work since my college. Currently I am working as a trainee in a chemical industry. My request to you sir is to come up with distillation column operation videos. Common problems and troubleshooting.
@faisaljummal8101
@faisaljummal8101 2 жыл бұрын
Very nice. 2 times me 90% samjha mai
@emc2xenon46
@emc2xenon46 Жыл бұрын
16:14 ❓How temperature is decreasing when we see the tie line in Txy plot 🔴 Xa (Xa is MVC composition in liq) decreasing >> Temp of Tie line increased (Txy diagram se) 🔴 Top pressure not changing so Txy diagram also not changing
@yashchoukse2874
@yashchoukse2874 Жыл бұрын
Please explain the hot vapour by pass method of pressure control.It would be very helpful.
@RahulMaurya-vt9hk
@RahulMaurya-vt9hk Жыл бұрын
Well cleared concept❤ . I have done apprenticeship iocl panipat. So i can understanding Easley
@srinivasanvenkatasubramani1670
@srinivasanvenkatasubramani1670 2 жыл бұрын
Very well explained. Thanks. About the spray nozzles, you may consider to add the following: In large columns, liquid is sprayed by nozzles through pipes arranged like a spider. Liquid forms a cone shape while flowing down. There will be many spray cones. These cones must be overlapping with each other, so that the vapors coming from below must pass through the liquid spray. If there are no overlaps, the hot vapors can have free ride and can cause coking. At the periphery of the column , overlapping of spray may not be possible. Such locations are called Dead Zones. The percentage of Dead Zones is kept minimum. This aspect is considered while designing.
@SandeepAcademy9
@SandeepAcademy9 2 жыл бұрын
Thank you sir for valuable information!
@aishadkhan7001
@aishadkhan7001 3 жыл бұрын
Dear sir Thanks for the video sir you are doing a fabulous job. #Thanks for your priceless work.
@SandeepAcademy9
@SandeepAcademy9 3 жыл бұрын
Thanks and welcome
@shashirathod6002
@shashirathod6002 2 жыл бұрын
Bahot badhiya bhaisaab
@mukendrapatel1
@mukendrapatel1 2 жыл бұрын
Very clear concept
@soumenkundu1214
@soumenkundu1214 3 жыл бұрын
Excellent to the power Excellent
@sunilsahu2525
@sunilsahu2525 2 жыл бұрын
Good explanation
@gurudayal3438
@gurudayal3438 3 жыл бұрын
Hello Good evening sir. One q, When increase the reflux ratio in distillation colunm then, 1) increase mass transfer, 2) increase heat transfer , 3) increase vapour pressure. 4) 1&2 boths . .
@SandeepAcademy9
@SandeepAcademy9 3 жыл бұрын
1&2 both...Go through this video. All concept will be cleared.
@yashchawade4569
@yashchawade4569 3 жыл бұрын
Sandeep sir tys for such learning vedio on distillation...! Sir, tellme how to calculate column diameter of distillation column? Have u made any specific vedio for design of distillation collumn? So that i can refer it! Plz reply asap🙏🙏
@aloogobhi4223
@aloogobhi4223 3 жыл бұрын
Sir great video can u tell how a control tray is decided for a distillation column and also how does that tray gurantees proper product specification .
@tvincentj
@tvincentj Жыл бұрын
thank you sir❤
@suryaprakashsahu6754
@suryaprakashsahu6754 3 жыл бұрын
Very informative video. Thank you so much sir. Can we reduce flooding i.e. maintain column to normal conditions by reducing reflux, condenser and reboiler duty? Also please clear how reflux drum T increases as we increase Reflux?
@SandeepAcademy9
@SandeepAcademy9 3 жыл бұрын
Depending upon condition if by increasing reflux fractionation getting worse.....then certainly reduce reflux to avoid flooding. However if Weeping/Dumping was taking place, in that case increasing reflux would be helpful. Overhead temp would increase if reboiler duty is fixed or if reboiler duty has been increased but top temp remain same. For overheard temperature think of LMTD. Delta T of both side.....if heat duty of condenser has been increased in that case LMTD must increase. Now condenser U/S side delta T has been increased (if top temp same) it means condenser d/S delta T sud decrease and hence overhead drum temp will increase. WRITE equation then only you will understand.
@akashingle7231
@akashingle7231 3 жыл бұрын
Sir design of shell and tube heat exchanger ka video banav ❤️
@shishirendra
@shishirendra Жыл бұрын
Reflux ratio par video banaye
@iftikharhaider6454
@iftikharhaider6454 Жыл бұрын
what is best for Biodiesel distillation (Packed or tray)
@nkverma8915
@nkverma8915 3 жыл бұрын
Sir coloum me jo down cumer ki hight hoti h o column ke sabhi trays ke liye same height hoti h ya different hoti h? Only down cumer me liquid ki height ke karan pressure change hoti h sir.
@dk.who0
@dk.who0 4 ай бұрын
how to identify if flooding is downcomer backup flooding? or entrainment flooding?
@onel276
@onel276 2 жыл бұрын
Nice sir, Can anyone suggest me books to learn more about distilation column apart from lieberman
@souravkumar2522
@souravkumar2522 3 жыл бұрын
Sir, how to calculate steam requirements in reboiler ??
@ahsanraza7957
@ahsanraza7957 Жыл бұрын
Aoa Refinery waste water recover process tell me
@mounishredlapalli6331
@mounishredlapalli6331 Жыл бұрын
How to find feed tray in multicomponent distillation?
@shaktirajvlogs1353
@shaktirajvlogs1353 3 жыл бұрын
Thank u sir
@NilofarShaikh-e1i
@NilofarShaikh-e1i Жыл бұрын
If column pressure suddenly start decreasing then what will happen sir?
@najmulhassanofficial3104
@najmulhassanofficial3104 3 жыл бұрын
Thnks appreciated ..
@SandeepAcademy9
@SandeepAcademy9 3 жыл бұрын
Always welcome
@boraddivyesh3872
@boraddivyesh3872 2 жыл бұрын
Sir why reflux drum's temprature increased while we are increasing reflux??
@adilsaifitech838
@adilsaifitech838 3 жыл бұрын
Sir, valve series me safety valve per bhi video upload kijiye please.
@SandeepAcademy9
@SandeepAcademy9 3 жыл бұрын
ab aur nahi bhi....next time ....
@harendrasingh7323
@harendrasingh7323 3 жыл бұрын
Sir NFL ke liye koi book bataiye
@jayendrakumarpatel1896
@jayendrakumarpatel1896 2 жыл бұрын
Distillation affected factor video to be share in Hindi
@mdmansari98
@mdmansari98 3 жыл бұрын
How to calculate 100 mmHg pressure drop in heat exchanger
@akashingle7231
@akashingle7231 3 жыл бұрын
❤️❤️❤️❤️❤️
@velavan948
@velavan948 2 жыл бұрын
Sir Please Share reference book
@NilofarShaikh-e1i
@NilofarShaikh-e1i Жыл бұрын
If column pressure suddenly start decreasing then what will happen sir?
@NilofarShaikh-e1i
@NilofarShaikh-e1i Жыл бұрын
If column pressure suddenly start decreasing then what will happen sir?
MAWP vs Design Pressure | Overpressure & Accumulation | Operating P & Hydrotest P | PSV Set Pressure
15:47
How steam stripper column works in Hindi | Steam stripper column working principle
21:33
Sandeep Academy [IITR, GATE AIR 1]
Рет қаралды 6 М.
Chain Game Strong ⛓️
00:21
Anwar Jibawi
Рет қаралды 41 МЛН
It works #beatbox #tiktok
00:34
BeatboxJCOP
Рет қаралды 41 МЛН
黑天使只对C罗有感觉#short #angel #clown
00:39
Super Beauty team
Рет қаралды 36 МЛН
Packed Tower vs Tray Tower | Chemical Engineering interview question answered | Hindi
26:45
Sandeep Academy [IITR, GATE AIR 1]
Рет қаралды 32 М.
Part 2 - Flooding in distillation Column: Entrainment or Jet Flooding in distillation | Hindi
21:22
Sandeep Academy [IITR, GATE AIR 1]
Рет қаралды 22 М.
Part 1- Crude distillation unit & FCC MF Column operation | Distillation column operation in Hindi
35:04
Vacuum Distillation Unit Ejector System in Hindi
27:31
Sandeep Academy [IITR, GATE AIR 1]
Рет қаралды 24 М.
Part 1 : Cavitation in centrifugal Pump & its symptoms| How Cavitation occurs in Hindi
21:59
Sandeep Academy [IITR, GATE AIR 1]
Рет қаралды 72 М.
Distillation   Control Systems
17:22
Rusell Hills
Рет қаралды 90 М.
Distillation Column Operation in Hindi
12:18
ALCHEMY ACADEMY
Рет қаралды 144 М.
Part 3 - Flooding in distillation Column: Downcomer Backup flooding and downcomer choke flooding
20:00