MAWP vs Design Pressure | Overpressure & Accumulation | Operating P & Hydrotest P | PSV Set Pressure

  Рет қаралды 19,802

Sandeep Academy [IITR, GATE AIR 1]

Sandeep Academy [IITR, GATE AIR 1]

Күн бұрын

Пікірлер: 43
@shanchem04
@shanchem04 2 жыл бұрын
Bro you are just awesome and i'am also chemical engineer and your explanation seems to be like experinced professional and not like college lecturer. Kindly explain in english and don't bother about anyone. You are really helping a lot. Continue your service.
@SandeepAcademy9
@SandeepAcademy9 2 жыл бұрын
When I upload in English then I get so many comments for uploading in Hindi. I simply can not upload in 2 language because of time constraint.
@vaishnavirajhans6208
@vaishnavirajhans6208 11 ай бұрын
Keep in Hindi sir. 👍
@soumenkundu1214
@soumenkundu1214 2 жыл бұрын
Highly informative from highly informed person....aap ki sath ho nothing is confusing at all....love you sir....
@kishanajudiya326
@kishanajudiya326 Жыл бұрын
Sir I'm doing job, your vedios are very helpful for understanding real life concepts regarding static and rotating equipment, Thank you sir 🙏
@debasishmondal495
@debasishmondal495 Жыл бұрын
Please give some information about code and standard for design aspects. I m 17yrs experience in design but whenever i see ur videos its always something new.
@avinashmokashe527
@avinashmokashe527 Жыл бұрын
Thanks You So much sandip sir .❤
@arjunkumark7485
@arjunkumark7485 Жыл бұрын
Great Explanation. Thank you for the summarized information.
@joyee9283
@joyee9283 2 жыл бұрын
Your informative videos are highly beneficial for non chemical engineers like us working in the refining industry. Thank u for the well put in effort. A kind request: could u put up a video on the explanation of amine strength, its effect, kinds of ami e and their merits/demerits and associated knowledge in the industry!
@chanchalnaskar104
@chanchalnaskar104 Ай бұрын
Great sir. It's truly informative & knowledge gathering video that you uploaded sir. Sir please share references book name for psv size calculation or troubleshooting..
@MuhammadZubair-lr5fd
@MuhammadZubair-lr5fd Жыл бұрын
Nicely explained 👌
@pramodkushwaha1089
@pramodkushwaha1089 2 жыл бұрын
Well explained. Thank you so much.
@srikantakumarmohanty7989
@srikantakumarmohanty7989 Жыл бұрын
Great explanation
@sultandalal3337
@sultandalal3337 Жыл бұрын
Very well explained
@VehiclesBro
@VehiclesBro 2 жыл бұрын
Once again very good informative video💐💐
@vaishnavirajhans6208
@vaishnavirajhans6208 11 ай бұрын
thank you sir, great explanation
@RahulPatil-vm8dl
@RahulPatil-vm8dl Жыл бұрын
Thank you so much sir 🙏
@ShwetaSharma-vu3me
@ShwetaSharma-vu3me 4 ай бұрын
Very nice
@samadkazi2252
@samadkazi2252 2 жыл бұрын
Nice efforts
@sounaksarkar8696
@sounaksarkar8696 2 жыл бұрын
Sir please make a video about the auxiliaries of a compressor and the common arrangement comprising of units like sunction kod, aop, rundown tank etc.
@krishnendu2008
@krishnendu2008 2 жыл бұрын
Very nice....Thank you
@sonututorialbihar
@sonututorialbihar 2 жыл бұрын
Rupture disk ke bare me kuchh bataiye sir.
@ShwetaSharma-vu3me
@ShwetaSharma-vu3me 4 ай бұрын
Please make a video on 3% pressure drop loss in psv inlet line.
@grandhivenkatachalapathira1588
@grandhivenkatachalapathira1588 7 ай бұрын
Very good explanation. Thanks for such videos. Q1.when we see the P&ID psv set value remains the same for cases, even where multiple psv's are available. I haven't seen any case where one psv set value is set at 50 and other at 52.5kgf/cm2g. Just for information. Q2. As the MAWP/MAAP or lessthan the hydrotest pressure, does that mean we can run the vessel at high pressures above design for specific period of time? If so how much? Considering psv in isolated condition. Q3. How to calculate the burst pressure? Q4. From where do we find the MAWP values of different vessels in the process unit? Thabk
@avadeshkumarmishra1134
@avadeshkumarmishra1134 6 күн бұрын
Hi Sandeep ji, can you just explain using formula how to calculate shell thickness with the available design pressure
@ankur7968
@ankur7968 Жыл бұрын
Can you please suggest me some books as i am preparing for boiler inspector and boe
@adhil263
@adhil263 2 жыл бұрын
Sir I have one doubt I have lecture notes and standard book but to get grip own concept i want to watch nptel lectures so did u take notes from nptel while u were preparing
@SandeepAcademy9
@SandeepAcademy9 2 жыл бұрын
Yes, I used to make notes while watching nptel videos.
@kamalkosta8570
@kamalkosta8570 10 ай бұрын
Which NPTEL course you Followed
@conceptchemtech6536
@conceptchemtech6536 2 жыл бұрын
Sir iske liye konsa book refer kiya apne?
@manivarman7082
@manivarman7082 2 жыл бұрын
What book u have referrred for indian standard?
@debasishmondal495
@debasishmondal495 Жыл бұрын
If PSV set at design pressure in that case working pressure and MAWP are same whatever as per API 520 it is also valid for more volatile components
@prashantkashyap3361
@prashantkashyap3361 2 жыл бұрын
Sir why blowdown occurs?
@ashutoshsingh1137
@ashutoshsingh1137 Жыл бұрын
Rated pressure????
@khan_boy_088
@khan_boy_088 2 жыл бұрын
15.88 mm(OD) x 0.6mm thickness of copper tubes length 10 MTR IS 11329 clause no. 7.3.1 ke anusar disign pressure low side and Haiger side kitna hoga. Kindly update us.
@raghunandansinghchauhan5749
@raghunandansinghchauhan5749 4 ай бұрын
Sir its too much confusing ,between psv and prv when u r relating with terms..pls add short vidio so its clear terms related to safty valve and relef valve..
@rkmusic2645
@rkmusic2645 2 жыл бұрын
Sir voice thoda kabhi kabhi slow ho jata hai...mic suitable nahi hai
@SandeepAcademy9
@SandeepAcademy9 2 жыл бұрын
koi aur aisa complain nahi kiya....batayie to kis time pe voice slow ho gaya hai ?
@digiraja0073
@digiraja0073 10 ай бұрын
Hi.
@digiraja0073
@digiraja0073 10 ай бұрын
Mesh rm.
@digiraja0073
@digiraja0073 10 ай бұрын
Mesram
@khalilurrahamandewan9047
@khalilurrahamandewan9047 2 жыл бұрын
Blowdown last pe samaj nehi aya
@SandeepAcademy9
@SandeepAcademy9 2 жыл бұрын
koi baat nahi....Next video will be on PSV. Everything will be clear in that video.
Safety valve and Relief valve difference | Safety valve & Relief valve working Principle in Hindi
23:54
What is Operating pressure, Maximum operating pressure, Design pressure & MAWP?
12:35
The evil clown plays a prank on the angel
00:39
超人夫妇
Рет қаралды 53 МЛН
Sigma Kid Mistake #funny #sigma
00:17
CRAZY GREAPA
Рет қаралды 30 МЛН
What is MAWP and How to derive MAWP ?
9:31
Static Equipment Design Training
Рет қаралды 3,7 М.
How to Calculate Hydrotest Pressure as per ASME & PED
5:46
Simple Science
Рет қаралды 76 М.
Difference between relieving pressure and set pressure for a PSV (9 of n)
1:11
Converge Engineering Pvt. Ltd.
Рет қаралды 1,2 М.
What's the Difference Between a Conventional and Bellows PSV?
8:06
Love The Process
Рет қаралды 29 М.
PSV Sizing in HYSYS Simulation
18:19
Process Engineering Guy
Рет қаралды 8 М.
What is MAWP? Maximum Allowable Working Pressure | By Express Engineering Training Services
17:07
Express Engineering Training Services
Рет қаралды 9 М.
Hydro testing /hydro testing of pipeline/hydro testing complete knowledge
16:49
Mechanical Fabrication 786
Рет қаралды 124 М.
What is  MAWP, Design ,Operating & Hydrotest Pressure ?
3:41
HardHat Engineer
Рет қаралды 77 М.