Fluke 845AB Needle Porn

  Рет қаралды 400

tgsoapbox

tgsoapbox

Күн бұрын

Пікірлер: 16
@largepimping
@largepimping Жыл бұрын
Stepbro, your needle is perfectly centred on zero.
@tgsoapbox
@tgsoapbox Жыл бұрын
LOL
@tarheels100
@tarheels100 Жыл бұрын
Best thumbnail ever.
@tgsoapbox
@tgsoapbox Жыл бұрын
Got to love the KZbin AI - Updated....
@tarheels100
@tarheels100 Жыл бұрын
@@tgsoapbox They nailed it! 😂
@DrFrank-xj9bc
@DrFrank-xj9bc Жыл бұрын
quite noisy. looking forward to repair of chopper Neons.
@tgsoapbox
@tgsoapbox Жыл бұрын
Thanks, Dr. Frank - I see over on EEVBlog that people have used Barthelme 82305 neons as direct replacements (I'd like to try and keep the unit as original as possible) but I can't seem to find any - Suggestions on a source or other replacement?
@zdzisiek1979
@zdzisiek1979 Жыл бұрын
🙂👍
@harrybond007
@harrybond007 10 ай бұрын
What exactly is the problem?, no commentary no nothing?
@tgsoapbox
@tgsoapbox 10 ай бұрын
This was just a video showing the needle bouncing around due to the noise in the photo-chopper circuit - Really just a celebration of the D’Arsonval movement
@harrybond007
@harrybond007 10 ай бұрын
@@tgsoapbox OK, I was watching your video because I recently picked up a Fluke 845AB at a hamfest for next to nothing, it appears to work to some extent but it's not very accurate and the meter is very erratic. I guess this is a common problem, I'm not sure I even know where to start attempting to repair it. It's dated May 1969, mechanically it's in good shape.
@tgsoapbox
@tgsoapbox 10 ай бұрын
@@harrybond007 Dr Frank pointed out that he posted to this thread over on eevblog - www.eevblog.com/forum/metrology/teardown-fluke-845aabar-tweaks-and-mods-(and-repairs)/?all - about the neons and capacitor replacements that addressed the noise in his 845AB. I did a Neon update and showed that in a later video but I haven't yet looked at the caps in the unit. It'd be worth checking out that thread for insights into what might be going on with your meter.
@harrybond007
@harrybond007 10 ай бұрын
@@tgsoapbox thanks for the link, that is a great resource, I did search online but never found that, are these units still useful?, still used today?, the used ones on eBay are listed at high prices, even if not tested?
@tgsoapbox
@tgsoapbox 10 ай бұрын
@@harrybond007 Sort of, really depends on what you're doing. If you have an 8.5 digit meter then in most cases you can just move on from these - Though in one of the threads on EEVBlog they have a discussion about current bias and how these null meters are still better than the current 8.5 digit ones for metrology purposes. I had a chance to acquire one for a fairly inexpensive price along with a Kelvin-Varley divider so I thought I'd just go do it and see what goes - I am a noob when it comes to these units as well. Good luck.
@xufocom
@xufocom Жыл бұрын
+/- 1 uV - its normal (in specs)
@tgsoapbox
@tgsoapbox Жыл бұрын
Thanks, I do think it is out of spec as that wobble is on the 10uV setting in zero and operation (with nothing plugged in).
Fluke 845AB Needle Porn II
2:26
tgsoapbox
Рет қаралды 268
Agilent 3499A - Part1 1
14:18
tgsoapbox
Рет қаралды 661
Quando A Diferença De Altura É Muito Grande 😲😂
00:12
Mari Maria
Рет қаралды 45 МЛН
UFC 310 : Рахмонов VS Мачадо Гэрри
05:00
Setanta Sports UFC
Рет қаралды 1,2 МЛН
Chain Game Strong ⛓️
00:21
Anwar Jibawi
Рет қаралды 41 МЛН
Are integration tests better than unit tests -  Kevlin Henney
2:18
Dev Tools Made Simple
Рет қаралды 3 М.
Can MORE Dangerous Saw Blades Cut Wood?
23:40
Waterjet Channel
Рет қаралды 756 М.
Wood Stove Water Heater Experiment - Surprising Results!
19:53
Greenhill Forge
Рет қаралды 5 М.
Agilent E4419B - Investigation
12:21
tgsoapbox
Рет қаралды 737
HP 11683A Repair Part 1
20:50
tgsoapbox
Рет қаралды 668
HP 5351A   Refuse to be confused.
6:44
tgsoapbox
Рет қаралды 549
HP 432A Repair Part 7 - Works but way out of cal
10:56
tgsoapbox
Рет қаралды 685
HP432A Power Meter Doesn't Zero - Repair Part1
14:30
tgsoapbox
Рет қаралды 1,1 М.