Column size 9/15 with 6 Rods(16mm 4bars and 12mm 2bars with 8mm rings @6inch) and distance between two columns is 15.8feet. two rooms, each 12feet/15.8feet. Footing 6.5feet depth width 4x4, with 1feet 40mm and 2.5feet 20mm. Is this good for g+2 residential building?
@engrraufkhan98763 жыл бұрын
Nice lecture,sir Explain Difference between Tie beam and plinth beam
@intkhabahmad453 Жыл бұрын
Steel volume should be 1-2% of RCC volume for beam. Calculate it
@murthyau66203 жыл бұрын
Can we know from you, the load bearing of our existing Residential structure, to go for further floors, at professional consultation. Then how to communicate, please. Regards.
@javedalibukhari23264 ай бұрын
1 thing missed 😊 If the size of crank bar 19 fit what is the size of carnk position. What is the is the distribution size.. It is important as well.
@mohammadmuslim56943 жыл бұрын
Good lecture
@pradeepSuriyabandara Жыл бұрын
Thanks for the lesson what about if this G + 2 story with 5 ton of load
@anilshukla80753 жыл бұрын
Excellent knowledge
@lemdorbaАй бұрын
For G+2 building. 1. Column size 10 inches ×12 inches. 2. Steel rod used - 6 Nos : four 16mm and two 12 mm 3. Total 12 columns On one side, column distance is 17 feet. Is it safe??
@faruqahmedbusiness11053 жыл бұрын
Will you show the analysis. Formula or thumb rule for column and footing design like beam depth formula l/20 for depth.
@ph62633 жыл бұрын
Sir My newly constructed house have one of the beam of length of 5.2 m (16.5 ft) and one secondary beam is tested on it. It is 230×300mm but we used 4 no of steel bars of 16 mm at bottom and 2 nos of 16 mm + 1 no of 12 mm at top. So ll it sustain to that amount of load for longer period or developed crack??? As I see many engineers recommend more than 450 mm deep beam.
@identidem3 жыл бұрын
Thanks a lot o was looking for this for a long time but didn't find much info. The span I have is 22 ft. Columns 9*14inches, 4 bars16mm and 2 bars 12 mm door/lintel beam is 6inches and the roof beam is 12 inches deep 16mm bars. Will it be sufficient?
@hemantasingh86063 жыл бұрын
6 nos of 16mm in beam (10X12) for 20 feet span.column (12x12) 4 nos 16mm &4 nos 12mm for single room .can we build g+2?
@kswvidioyoutube88163 жыл бұрын
It's possible even I'm doing my own house with four 16 mm andtwo 12 mm in one biller size is 8/10
@ameehasa55043 жыл бұрын
How many crank bar we should use? I hope if u have video for framing on all type of soil
@fasterfaster59603 жыл бұрын
Baraka lahou fikkk
@kennethwhite51583 жыл бұрын
Sir, If we have four steel rods on the bottom of the beam and three steel rods in the column to tie off to how is it possible to tie the two middle rods in the beam to one middle rod in the column? I'm confused.
@amols96343 жыл бұрын
L/20 for 19 feet span 285mm depth so safer side you have to take 230x 380
@manjunathbc3655 Жыл бұрын
What should be size of beam and column and size of steel which is 7 meters and roof size and steel size G+3
@premjitchakpram42013 жыл бұрын
How about if we made column size 12x12 for G+2 residential house with steel rod of four 16mm and four 12mm?
@ramakantsalam61323 жыл бұрын
Totally safe
@alisherkhan53472 жыл бұрын
Waiting for response too
@dreamer692232 жыл бұрын
Is 12mm 5 bars, 16 mm 1 bar enough For 14 feet beam ( top 3 - 12mm, bottom 2 - 12mm and 1- 16 mm)??
@KusaasiraNoah74212 жыл бұрын
can you use 16mm diameter bars in columns and 20mm in beams?
@phyohtetkoko9292 жыл бұрын
Thanks For Teaching Sir
@syedabdulquddus34693 жыл бұрын
supper sir, Thank you very much
@ariezaziziacahlebih26373 жыл бұрын
Salam sir, does this can apply to 21 ft span?
@kaungsettlinn11798 ай бұрын
ACI code(Beam is. span× 0.75=beam depth)
@akojuravisankar34922 жыл бұрын
Thank you for giving good information about construction building.
@byrappakaramaradi40702 жыл бұрын
What should be the height of building?
@Mithushahome3 жыл бұрын
Super bro
@sridharsahoo4893 жыл бұрын
Sir u could not say top reiforcement which mm bar used in this video
@chatpatgamingyt27072 жыл бұрын
What will be the size of footing for same building if soil bearing capacity is 70kn/m2?
@SandeepKumar-eg1kw Жыл бұрын
It is good decision to choose deep foundation than shallow foundation if you cam to know soil is till 70kn of bearing
@engrijazali282 Жыл бұрын
if the span btween 2 column is 16ft...and the building is G+1+2 than explain size of column and beam...
@moamar75852 жыл бұрын
what is the thickness of footings?
@aemisection44603 жыл бұрын
please post a video for culvert reinforcement details and designs
@namahshivay8978 Жыл бұрын
Thanks 👍❣️
@defersonlyngdohmawlong7083 жыл бұрын
G 1 G2 G3 means what? Does it mean 1floor 2floor
@ayaan56333 жыл бұрын
Can you do your future video measurements in feet and inches.?
@awishhamza636811 ай бұрын
12x9'' beam isn't safe for 19-20 feet span in beam column structure. do stress analysis
@khan523102 жыл бұрын
If I have 24 feet span and other side is 26 feet span for G plus 1 story home only, please reply
@paonamdineshmangang61793 жыл бұрын
Sir is it OK to put 4 Steel rod of 16mm on top and 4 on bottom of 17.5 feet long beam
@ningthoujamnewtonmeitei51373 жыл бұрын
Sir can it apply in normal residential building
@salimmahmud16143 жыл бұрын
Maa shah Allah
@lakshmanang83163 жыл бұрын
Need plinth beam design
@lakshmanang83163 жыл бұрын
I have one doubt , In your previous video you say As per Indian standard min depth of beam is d/16 = 19/16= 1.2 ft but you say now 1 ft is enough . how !?
@jaiharris66063 жыл бұрын
L/20
@himangshupatra50003 жыл бұрын
SIR I HAVE 16 feet span G+1.stroy, i have provide beam ( 9 inch *12 inch ) , with 16 mm 2 bar, and 12 mm 1 bar at bottom, and 2 bar of 12 mm at top with 8mm stirrups @150mm c/c spacing, is it safe?? Also column size -(9"*15")
@ayaan56333 жыл бұрын
absolutely save for G+1
@trishan27393 жыл бұрын
Can you explain that what is column and beam size with how many steel used with size Also length and width distance of each column
@izharulhaq84357 ай бұрын
And calculate the no. Of beams for 40 by 16 feet
@nyantehemmanuel7089 Жыл бұрын
maximum span between columns
@intkhabahmad453 Жыл бұрын
Your beam steel is not correct for 19 ft span... Moreover depth of beam is also very less for 19 ft... It should be minimum 19 ft... Rest of the calculation and suggestions are well.
@ramakantapradhan79322 жыл бұрын
If column to column clear span 19', i want provide 6 nos 12mm bar in column and in beam 16mm 4nos bar, any problem plz solve it
@ramakantapradhan79322 жыл бұрын
Plz any comment
@musahhamid54612 жыл бұрын
Pls I need picture of G+1 and G+2 story building
@waluohopaulo21163 жыл бұрын
Well understood
@UmeshSahu-di2ee3 жыл бұрын
Wow bhai....
@kswvidioyoutube88163 жыл бұрын
Very nice explaination but not for the poor peaple it's too much and it will be very expensive less size column beam can biuld G+2
@muruganmuthusamy99763 жыл бұрын
Fine
@logisticsh.n.a.a41363 жыл бұрын
Do pakistan and india have the same engineering principles for rcc construction .
@MehrbanRana3 жыл бұрын
Dear All over the world is same principles. Even here in GCC countries are same principles.
@logisticsh.n.a.a41363 жыл бұрын
@@MehrbanRana thanks .
@DeepakKumar-oo9si2 жыл бұрын
18fit distance mi kon sa colum lgta hi
@mpannirselvam95122 жыл бұрын
36/60 what is the size of the pillar snd besm
@muhammadtahirmushtaq63002 жыл бұрын
good mashallah
@izharulhaq84357 ай бұрын
No. Of beams used for 40 by 16 feet
@shanjaiks75832 жыл бұрын
We are watching a religious programe . Inshallah
@izharulhaq84357 ай бұрын
Please answer my question
@nawalshrivastav6032 Жыл бұрын
Please hindi Language used.
@muhammadafzaal86703 жыл бұрын
Agr urdu mai lecture daitai to aor acha hota......
@palashmatubber84962 жыл бұрын
I love u sar
@252adeshpatade33 жыл бұрын
Sir for 3 storey house 6 no 12mm bars are sufficient or not Column size 9 * 15 " Please guide